A multi-level wavelet approach for automatic detection of epileptic spikes in the electroencephalogram
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 2×
“For a given f ∈ L2(R), Ajf represents the approximation at resolution level j and Djf represents the details of the signal [22,23].”
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
American Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
A review of wavelets in biomedical applications
Unser, M., & Aldroubi, A. (1996) · Proceedings of the IEEE · doi:10.1109/5.488704 · Cited by 754 · cited 1×
“Several approaches have been adopted for automatic detection of IEDs [10–14].”
MethodEMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696 · cited 1×
“To minimize contamination by non-epileptiform high frequency signals like myogenic artifacts, which lies in the frequency range 20–30 Hz over the anterior head regions and 40–80 Hz over the temporal regions [25], we focused on sub-bands 4 and 5 (frequency range 4–16 Hz) (Table 1).”
A new interpretation of nonlinear energy operator and its efficacy in spike detection
Mukhopadhyay, S., & Ray, G. C. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661266 · Cited by 385
Deuschl, G., & Eisen, A. (1999) · PubMed · Cited by 345
Phase behavior and crystallization kinetics of PHSA-coated PMMA colloids
Auer, S., Poon, W. C. K., & Frenkel, D. (2003) · Physical Review E · Cited by 265
Wavelet preprocessing for automated neural network detection of EEG spikes
Kalayci, T., & Ozdamar, O. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376754 · Cited by 264 · cited 2×
“It has been observed that the optimal resolution to analyze IEDs corresponds to the frequency band 4–32 Hz [16,17,19,20].”
Noachtar, S., Binnie, C. D., Ebersole, J., Mauguı̀ere, F., Sakamoto, A. C., & Westmoreland, B. (1999) · PubMed · Cited by 254
A multistage system to detect epileptiform activity in the EEG
Dingle, A. A., Jones, R. D., Carroll, G. J., & Fright, W. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250582 · Cited by 199
Acır, N., Öztura, İ., Kuntalp, M., Baklan, B., & Guzelis, C. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839630 · Cited by 163
Modern electroencephalography: its role in epilepsy management
Binnie, C. D., & Stefan, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00125-x · Cited by 159 · cited 6×
“During the interictal period (in between seizures) the EEG of a patient with epilepsy may exhibit paroxysmal transients in the form of spikes and sharp waves [2,5].”
BackgroundInfluentialGlover, J. R., Raghaven, N., Ktonas, P. Y., & Frost, J. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.24253 · Cited by 106 · cited 1×
“Compared with these methods, wavelet transform method is more appropriate for analysis of non-stationary signals and represents a major advantage over spectral analysis, as it is well suited for analyzing the time, space and frequency domains of EEG signals [18,20,31–33].”
MethodEpileptiform Electroencephalographic Patterns
Westmoreland, B. F. (1996) · Mayo Clinic Proceedings · doi:10.4065/71.5.501 · Cited by 82 · cited 6×
“During the interictal period (in between seizures) the EEG of a patient with epilepsy may exhibit paroxysmal transients in the form of spikes and sharp waves [2,5].”
InfluentialMultiresolution decomposition of non-stationary eeg signals: A preliminary study
Clark, I., Biscay, R., Echeverría, M., & Virués, T. (1995) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00014-u · Cited by 65 · cited 1×
“It has been observed that the optimal resolution to analyze IEDs corresponds to the frequency band 4–32 Hz [16,17,19,20].”
Detection of epileptic events in electroencephalograms using wavelet analysis
D’Attellis, C. E., Isaacson, S. I., & Sirne, R. O. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02648043 · Cited by 60
Prevalence of benign epileptiform variants observed in an EEG laboratory from South India
Radhakrishnan, K., Santoshkumar, B., & Venugopal, A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00002-9 · Cited by 49 · cited 1×
“In addition, benign sharp transients such as wicket waves and sleep related activities might simulate IEDs [8,9].”
BackgroundSelf-citation
Cited by
Wavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis
Faust, O., Acharya, U. R., Adeli, H., & Adeli, A. (2015) · Seizure · doi:10.1016/j.seizure.2015.01.012 · Cited by 572
Safieddine, D., Kachenoura, A., Albera, L., Birot, G., Karfoul, A., Pasnicu, A., Biraben, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2012-127 · Cited by 198
“Regarding the wavelets transform (WT), it has been used in the EEG context for the detection of epileptiform patterns [17], for the elimination of different types of noises [18,19] and for removal of some electrophysiological artifacts, such as ocular movement [20,21], and heart signal [20,22].”
MethodLi, Y., Liu, Y., Guo, Y.-Z., Liao, X.-F., Hu, B., & Yu, T. (2022) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2021.3071860 · Cited by 196
Seizure Prediction Using Spike Rate of Intracranial EEG
Li, S., Zhou, W., Yuan, Q., & Liu, Y. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282153 · Cited by 170
Epilepsy Classification for Mining Deeper Relationships between EEG Channels based on GCN
Chen, X., Zheng, Y., Niu, Y., & Li, C. (2020) · 2020 International Conference on Computer Vision, Image and Deep Learning (CVIDL) · doi:10.1109/cvidl51233.2020.00050 · Cited by 34
Metadata
- Authors
- Indiradevi, K. P., Elias, E., Sathidevi, P. S., Dinesh Nayak, S., & Radhakrishnan, K.
- Venue
- Computers in Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2008-07
- Volume
- 38
- Issue
- 7
- Pages
- 805-816
- ISSN
- 0010-4825 (ISSN-L)
- OpenAlex
- W2046233769
- Cited by
- 170
- References
- 19
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.