CoChat

Applying supervised contrastive learning for the detection of diabetic retinopathy and its severity levels from fundus images

Open access
Islam, Md Robiul, Abdulrazak, Lway Faisal, Nahiduzzaman, Md, Goni, Md Omaer Faruq, Anower, Md Shamim, Ahsan, Mominul, Haider, Julfikar, Kowalski, Marcin · 2022 · Computers in Biology and Medicine
Cited by 175

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Diabetic Retinopathy (DR) is a major complication in human eyes among the diabetic patients. Early detection of the DR can save many patients from permanent blindness. Various artificial intelligent based systems have been proposed and they outperform human analysis in accurate detection of the DR. In most of the traditional deep learning models, the cross-entropy is used as a common loss function in a single stage end-to-end training method. However, it has been recently identified that this loss function has some limitations such as poor margin leading to false results, sensitive to noisy data and hyperparameter variations. To overcome these issues, supervised contrastive learning (SCL) has been introduced. In this study, SCL method, a two-stage training method with supervised contrastive loss function was proposed for the first time to the best of authors' knowledge to identify the DR and its severity stages from fundus images (FIs) using "APTOS 2019 Blindness Detection" dataset. "Messidor-2" dataset was also used to conduct experiments for further validating the model's performance. Contrast Limited Adaptive Histogram Equalization (CLAHE) was applied for enhancing the image quality and the pre-trained Xception CNN model was deployed as the encoder with transfer learning. To interpret the SCL of the model, t-SNE method was used to visualize the embedding space (unit hyper sphere) composed of 128 D space into a 2 D space. The proposed model achieved a test accuracy of 98.36%, and AUC score of 98.50% to identify the DR (Binary classification) and a test accuracy of 84.364%, and AUC score of 93.819% for five stages grading with the APTOS 2019 dataset. Other evaluation metrics (precision, recall, F1-score) were also determined with APTOS 2019 as well as with Messidor-2 for analyzing the performance of the proposed model. It was also concluded that the proposed method achieved better performance in detecting the DR compared to the conventional CNN without SCL and other state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2022.105602

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Islam, M. R., Abdulrazak, L. F., Nahiduzzaman, M., Goni, M. O. F., Anower, M. S., Ahsan, M., Haider, J., & Kowalski, M.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2022-07
Volume
146
Pages
105602
ISSN
0010-4825 (ISSN-L)
OpenAlex
W4229451621
Cited by
175
References
6
FWCI
18.79
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Applying supervised contrastive learning for the detection of diabetic retinopathy and its severity levels from fundus images. https://app.cochat.ai/papers/10.1016/j.compbiomed.2022.105602
The paper
Islam, M. R., Abdulrazak, L. F., Nahiduzzaman, M., Goni, M. O. F., Anower, M. S., Ahsan, M., Haider, J., & Kowalski, M. (2022). Applying supervised contrastive learning for the detection of diabetic retinopathy and its severity levels from fundus images. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2022.105602

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.