The DOI matches its Crossref record; 153 of the 157 references it cites were found in a registry or an index.
Computer-aided diagnosis in medical imaging: Historical review, current status and future potential
Open accessAbstract
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a "second opinion" and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists' accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of interstitial lung diseases. In order to assist in the differential diagnosis, it would be possible to search for and retrieve images (or lesions) with known pathology, which would be very similar to a new unknown case, from PACS when a reliable and useful method has been developed for quantifying the similarity of a pair of images for visual comparison by radiologists.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Radiological imaging can be extremely complex, and it is recognized that the analysis of exams that produce hundreds of images, such as computed tomography (CT) and magnetic resonance imaging (MRI), poses challenges, even for experienced specialists(1-3).”
From Artificial intelligence, machine learning, computer-aided diagnosis, and radiomics: advances in imaging towards to precision medicine (2019) · cites this paper as [3]
Citations
Cites
Black, D. M., Cummings, S. R., Karpf, D. B., Cauley, J. A., Thompson, D. E., Nevitt, M. C., Bauer, D. C., Genant, H. K., Haskell, W. L., Marcus, R., et al. (1996) · The Lancet · doi:10.1016/s0140-6736(96)07088-2 · Cited by 3,846
Vertebral fracture assessment using a semiquantitative technique
Genant, H. K., Wu, C. Y., van Kuijk, C., & Nevitt, M. C. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080915 · Cited by 3,691
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J. H., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,504
Liberman, U. A., Weiss, S. R., Bröll, J., Minne, H. W., Quan, H., Bell, N. H., Rodriguez-Portales, J. A., Downs, R. W., Dequeker, J., Favus, M. J., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511303332201 · Cited by 2,276
ROC Methodology in Radiologic Imaging
Metz, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,628
Chesnut, C. H., Silverman, S., Andriano, K., Genant, H., Gimona, A., Harris, S., Kiel, D., LeBoff, M., Maricic, M., Miller, P., et al. (2000) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00490-3 · Cited by 1,122
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Henschke, C. I., Yankelevitz, D. F., Mirtcheva, R., McGuinness, G., McCauley, D. I., & Miettinen, O. S. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.5.1781053 · Cited by 904
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
Metz, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 861
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 832
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 748
Bone Imaging in Metastatic Breast Cancer
Hamaoka, T., Madewell, J. E., Podoloff, D. A., Hortobágyi, G. N., & Ueno, N. T. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.08.181 · Cited by 652
Potential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Burhenne, L. J. W., Wood, S. A., D’Orsi, C. J., Feig, S. A., Kopans, D. B., O′Shaughnessy, K. F., Sickles, E. A., Tabár, L. K., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 552
The detection and management of unruptured intracranial aneurysms
Wardlaw, J. M., & White, P. (2000) · Brain · doi:10.1093/brain/123.2.205 · Cited by 549
Computer-aided diagnosis in chest radiography: a survey
van Ginneken, B., Romeny, B. M. T. H., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 517
Visual Scanning, Pattern Recognition and Decision-making in Pulmonary Nodule Detection
Kundel, H. L., Nodine, C. F., & Carmody, D. P. (1978) · Investigative Radiology · doi:10.1097/00004424-197805000-00001 · Cited by 451
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 439
Self-citationRecognition of Vertebral Fracture in a Clinical Setting
Gehlbach, S. H., Bigelow, C., Heimisdóttir, M., May, S. J., Walker, A. M., & Kirkwood, J. R. (2000) · Osteoporosis International · doi:10.1007/s001980070078 · Cited by 414
Handbook of Medical Imaging. Processing and Analysis
Bankman, I. N., & Morcovescu, Ş. (2002) · Medical Physics · doi:10.1118/1.1429630 · Cited by 396
Clinical consequences of vertebral fractures
Ross, P. D. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)90025-5 · Cited by 368
Improvement in Radiologists?? Detection of Clustered Microcalcifications on Mammograms
Chan, H., Doi, K., VYBRONY, C. J., Schmidt, R. A., Metz, C. E., Lam, K. L., Ogura, T., WU, Y., & MacMahon, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 356
Self-citationLi, Q., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1581411 · Cited by 350
Self-citationLung cancer detected during a screening program using four-month chest radiographs.
Muhm, J. R., Miller, W. E., Fontana, R. S., SANDERSON, D. R., & Uhlenhopp, M. A. (1983) · Radiology · doi:10.1148/radiology.148.3.6308709 · Cited by 341
Chan, H., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M. (1987) · Medical Physics · doi:10.1118/1.596065 · Cited by 339
Self-citationWhite, P., Teasdale, E. M., Wardlaw, J. M., & Easton, V. (2001) · Radiology · doi:10.1148/radiology.219.3.r01ma16739 · Cited by 329
Improving breast cancer diagnosis with computer-aided diagnosis
Jiang, Y., Nishikawa, R. M., Schmidt, R. A., Metz, C. E., Giger, M. L., & Doi, K. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80058-0 · Cited by 310
Self-citationMiss Rate of Lung Cancer on the Chest Radiograph in Clinical Practice
Quekel, L. G. B. A., Kessels, A. G. H., Goei, R., & van Engelshoven, J. M. A. (1999) · CHEST Journal · doi:10.1378/chest.115.3.720 · Cited by 310
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 309
Self-citationGur, D., Sumkin, J. H., Rockette, H. E., Ganott, M. A., Hakim, C. M., Hardesty, L. A., Poller, W. R., Shah, R., & Wallace, L. P. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh067 · Cited by 306
Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 278
Self-citationAustin, J. H. M., Romney, B. M., & Goldsmith, L. S. (1992) · Radiology · doi:10.1148/radiology.182.1.1727272 · Cited by 265
Interpreting Chest Radiographs without Visual Search
Kundel, H. L., & Nodine, C. F. (1975) · Radiology · doi:10.1148/116.3.527 · Cited by 254
Deslauriers, J., Brisson, J., Cartier, R., Fournier, M., Gagnon, D., Piraux, M., & Beaulieu, M. (1989) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34540-4 · Cited by 253
Giger, M. L., Doi, K., & MacMahon, H. (1988) · Medical Physics · doi:10.1118/1.596247 · Cited by 250
Self-citationChan, H., Sahiner, B., Helvie, M. A., Petrick, N., Roubidoux, M. A., Wilson, T. E., Adler, D. D., Paramagul, C., Newman, J. S., & Sanjay‐Gopal, S. (1999) · Radiology · doi:10.1148/radiology.212.3.r99au47817 · Cited by 245
Deslauriers, J., Brisson, J., Cartier, R., et al. (1989) · PubMed · Cited by 245
Kobayashi, T., Xu, X., MacMahon, H., Metz, C. E., & Doi, K. (1996) · Radiology · doi:10.1148/radiology.199.3.8638015 · Cited by 244
Self-citationYoshida, H., Masutani, Y., MacEneaney, P. M., Rubin, D. T., & Dachman, A. H. (2002) · Radiology · doi:10.1148/radiol.2222010506 · Cited by 241
PACS and Imaging Informatics: Basic Principles and Applications
(2005) · Radiology · doi:10.1148/radiol.2353052512 · Cited by 237
Winsberg, F., Elkin, M., Macy, J., Bordaz, V., & Weymouth, W. H. (1967) · Radiology · doi:10.1148/89.2.211 · Cited by 236
Computer-aided diagnosis in radiology: potential and pitfalls
Doi, K., MacMahon, H., Katsuragawa, S., Nishikawa, R. M., & Jiang, Y. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00016-9 · Cited by 230
Self-citationLenchik, L., Rogers, L. F., Delmas, P. D., & Genant, H. K. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.4.1830949 · Cited by 228
Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006) · Radiology · doi:10.1148/radiol.2392042121 · Cited by 218
Digital image subtraction of temporally sequential chest images for detection of interval change
Kano, A., Doi, K., MacMahon, H., Hassell, D. D., & Giger, M. L. (1994) · Medical Physics · doi:10.1118/1.597308 · Cited by 214
Self-citationHuston, J., Nichols, D. A., Luetmer, P. H., Goodwin, J. T., Meyer, F. B., Wiebers, D. O., & Weaver, A. L. (1994) · PubMed Central · Cited by 207
Malignant and benign clustered microcalcifications: automated feature analysis and classification.
Jiang, Y., Nishikawa, R. M., Wolverton, D., Metz, C. E., Giger, M. L., Schmidt, R. A., Vyborny, C. J., & Doi, K. (1996) · Radiology · doi:10.1148/radiology.198.3.8628853 · Cited by 202
Self-citationLi, F., Sone, S., Abé, H., MacMahon, H., Armato, S. G., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011375 · Cited by 196
Self-citationComputer-aided Detection with Screening Mammography in a University Hospital Setting
Birdwell, R. L., Bandodkar, P., & Ikeda, D. M. (2005) · Radiology · doi:10.1148/radiol.2362040864 · Cited by 187
Guest editorial computer-aided diagnosis in medical imaging
Giger, M. L., Karssemeijer, N., & Armato, S. G. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2001.974915 · Cited by 187
Korogi, Y., Takahashi, M., Katada, K., Ogura, Y., Hasuo, K., Ochi, M., Utsunomiya, H., Abe, T., & Imakita, S. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma02497 · Cited by 185
Computer Diagnosis of Pneumoconiosis
Kruger, R. P., Thompson, W. B., & Turner, A. (1974) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1974.5408519 · Cited by 174
Dean, J. C., & Ilvento, C. C. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0111 · Cited by 163
Computer-aided Diagnosis Scheme for Detection of Polyps at CT Colonography
Yoshida, H., Näppi, J. J., MacEneaney, P. M., Rubin, D. T., & Dachman, A. H. (2002) · Radiographics · doi:10.1148/radiographics.22.4.g02jl16963 · Cited by 155
Investigation of basic imaging properties in digital radiography. I. Modulation transfer function
Giger, M. L., & Doi, K. (1984) · Medical Physics · doi:10.1118/1.595629 · Cited by 155
Self-citationLesion conspicuity, structured noise, and film reader error
Kundel, H., & Révész, G. (1976) · American Journal of Roentgenology · doi:10.2214/ajr.126.6.1233 · Cited by 150
Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum
Giger, M. L., Doi, K., & Metz, C. E. (1984) · Medical Physics · doi:10.1118/1.595583 · Cited by 149
Self-citationImpact of Computer-Aided Detection in a Regional Screening Mammography Program
Cupples, T. E., Cunningham, J. E., & Reynolds, J. C. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1300 · Cited by 149
MacMahon, H., Vyborny, C. J., Metz, C. E., Doi, K., Sabeti, V., & Solomon, S. L. (1986) · Radiology · doi:10.1148/radiology.158.1.3940383 · Cited by 148
Self-citationComputer Diagnosis of Primary Bone Tumors
Lodwick, G. S., HAUN, C., Smith, W. E., Keller, R. F. M. S., & Robertson, E. D. (1963) · Radiology · doi:10.1148/80.2.273 · Cited by 147
Nakamura, K., Yoshida, H., Engelmann, R. M., MacMahon, H., Katsuragawa, S., Ishida, T., Ashizawa, K., & Doi, K. (2000) · Radiology · doi:10.1148/radiology.214.3.r00mr22823 · Cited by 146
Self-citationArimura, H., Katsuragawa, S., Suzuki, K., Li, F., Shiraishi, J., Sone, S., & Doi, K. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.02.009 · Cited by 144
Self-citationXu, X., Doi, K., Kobayashi, T., MacMahon, H., & Giger, M. L. (1997) · Medical Physics · doi:10.1118/1.598028 · Cited by 144
Self-citationKakeda, S., Moriya, J., Sato, H., Aoki, T., Watanabe, H., Nakata, H., Oda, N., Katsuragawa, S., Yamamoto, K., & Doi, K. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.2.1820505 · Cited by 139
Self-citationKatsuragawa, S., Doi, K., & MacMahon, H. (1988) · Medical Physics · doi:10.1118/1.596224 · Cited by 137
Self-citationCerebral aneurysms: evaluation with three-dimensional CT angiography.
Ogawa, T., Okudera, T., Noguchi, K., Sasaki, N., Inugami, A., Uemura, K., & Yasui, N. (1996) · PubMed Central · Cited by 135
Boreman, G. D. (2009) · SPIE eBooks · doi:10.1117/3.294180.ch2 · Cited by 135
Digital image processing: effect on detectability of simulated low-contrast radiographic patterns.
Ishida, M., Doi, K., Loo, L. N., Metz, C. E., & Lehr, J. L. (1984) · Radiology · doi:10.1148/radiology.150.2.6691118 · Cited by 134
Self-citationHuo, Z., Giger, M. L., Vyborny, C. J., & Metz, C. E. (2002) · Radiology · doi:10.1148/radiol.2242010703 · Cited by 133
Underreporting of Vertebral Fractures on Routine Chest Radiography
Kim, N., Rowe, B. H., Raymond, G. S., Jen, H., Colman, I., Jackson, S. A., Siminoski, K. G., Chahal, A. M., Folk, D., & Majumdar, S. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.2.1820297 · Cited by 125
Destounis, S. V., DiNitto, P. A., Logan-Young, W. W., Bonaccio, E., Zuley, M. L., & Willison, K. M. (2004) · Radiology · doi:10.1148/radiol.2322030034 · Cited by 124
Computer-aided Diagnosis of Pulmonary Nodules: Results of a Large-Scale Observer Test
MacMahon, H., Engelmann, R. M., Behlen, F. M., Hoffmann, K. R., Ishida, T., Roe, C., Metz, C. E., & Doi, K. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc27723 · Cited by 124
Self-citationOken, M. M., Marcus, P. M., Hu, P., BECK, T. M., Hocking, W. G., Kvale, P. A., Cordes, J. E., Riley, T. L., Winslow, S. D., Peace, S., et al. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji430 · Cited by 120
Feng, L., Arimura, H., Suzuki, K., Shiraishi, J., Li, Q., Abé, H., Engelmann, R. M., Sone, S., MacMahon, H., & Doi, K. (2005) · Radiology · doi:10.1148/radiol.2372041555 · Cited by 119
Self-citationAoyama, M., Li, Q., Katsuragawa, S., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1543575 · Cited by 109
Self-citationIshida, T., Katsuragawa, S., Nakamura, K., MacMahon, H., & Doi, K. (1999) · Medical Physics · doi:10.1118/1.598627 · Cited by 108
Self-citationComputer-aided diagnosis in chest radiography
Katsuragawa, S., & Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.003 · Cited by 104
Self-citationRadiographic screening in the early detection of lung cancer.
Fp, S., & Ms, T. (1978) · PubMed · Cited by 103
Computer-Aided Diagnosis in Mammography
Giger, M. L., Huo, Z., Kupinski, M. A., & Vyborny, C. J. (2010) · SPIE eBooks · doi:10.1117/3.831079.ch15 · Cited by 103
Fujita, H., Doi, K., & Giger, M. L. (1985) · Medical Physics · doi:10.1118/1.595653 · Cited by 101
Self-citationPattern recognition of chest X-ray images
Toriwaki, J., Suenaga, Y., Negoro, T., & Fukumura, T. (1973) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(73)90005-1 · Cited by 101
Digital chest radiography: effect of temporal subtraction images on detection accuracy.
DiFazio, M., MacMahon, H., Xu, X., Tsai, P., Shiraishi, J., Armato, S. G., & Doi, K. (1997) · Radiology · doi:10.1148/radiology.202.2.9015072 · Cited by 100
Self-citationAutomated Computer Analysis of Radiographic Images
Meyers, P. H., Nice, C. M., Becker, H. C., Nettleton, W. J., Sweeney, J. W., & Meckstroth, G. R. (1964) · Radiology · doi:10.1148/83.6.1029 · Cited by 100
Li, F., Aoyama, M., Shiraishi, J., Abé, H., Li, Q., Suzuki, K., Engelmann, R. M., Sone, S., MacMahon, H., & Doi, K. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.5.1831209 · Cited by 96
Self-citationAshizawa, K., Ishida, T., MacMahon, H., Vyborny, C. J., Katsuragawa, S., & Doi, K. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80055-5 · Cited by 94
Self-citationYin, F.-F., Giger, M. L., Vyborny, C. J., Doi, K., & Schmidt, R. A. (1993) · Investigative Radiology · doi:10.1097/00004424-199306000-00001 · Cited by 93
Self-citationLi, Q., Li, F., Shiraishi, J., Katsuragawa, S., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1605351 · Cited by 89
Self-citationKatsuragawa, S., Doi, K., & MacMahon, H. (1989) · Medical Physics · doi:10.1118/1.596412 · Cited by 88
Self-citationArimura, H., Li, Q., Korogi, Y., Hirai, T., Abé, H., Yamashita, Y., Katsuragawa, S., Ikeda, R., & Doi, K. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.07.011 · Cited by 87
Self-citationAn Analysis of Perceptual and Cognitive Factors in Radiographic Interpretation
Carmody, D. P., Nodine, C. F., & Kundel, H. L. (1980) · Perception · doi:10.1068/p090339 · Cited by 87
Computerized analysis of images in the detection and diagnosis of breast cancer
Giger, M. L. (2004) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2004.07.003 · Cited by 86
Korogi, Y., Takahashi, M., Mabuchi, N., Hiroshi, M. I. K. I., Fujiwara, S., Horikawa, Y., Nakagawa, T., O’uchi, T., WATABE, T., & Shiga, H. (1994) · Radiology · doi:10.1148/radiology.193.1.8090889 · Cited by 83
Kruger, R. P., Townes, J. R., Hall, D. L., Dwyer, S. J., & Lodwick, G. S. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324115 · Cited by 82
Shiraishi, J., Li, Q., Suzuki, K., Engelmann, R. M., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2208739 · Cited by 80
Self-citationMetz, C. E. (2010) · SPIE eBooks · doi:10.1117/3.832716.ch15 · Cited by 80
Shiraishi, J., Abé, H., Engelmann, R. M., Aoyama, M., MacMahon, H., & Doi, K. (2003) · Radiology · doi:10.1148/radiol.2272020498 · Cited by 79
Self-citationAbé, H., MacMahon, H., Engelmann, R. M., Li, Q., Shiraishi, J., Katsuragawa, S., Aoyama, M., Ishida, T., Ashizawa, K., Metz, C. E., et al. (2003) · Radiographics · doi:10.1148/rg.231025129 · Cited by 75
Self-citationRoad Maps for Advancement of Radiologic Computer-aided Detection in the 21st Century
Summers, R. M. (2003) · Radiology · doi:10.1148/radiol.2291030010 · Cited by 74
Muramatsu, C., Li, Q., Suzuki, K., Schmidt, R. A., Shiraishi, J., Newstead, G. M., & Doi, K. (2005) · Medical Physics · doi:10.1118/1.1944913 · Cited by 74
Self-citationComputer-Aided diagnosis for CT colonography
Yoshida, H., & Dachman, A. H. (2004) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2004.07.002 · Cited by 71
Ashizawa, K., MacMahon, H., Ishida, T., Nakamura, K., Vyborny, C. J., Katsuragawa, S., & Doi, K. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.172.5.10227508 · Cited by 70
Self-citationAoyama, M., Li, Q., Katsuragawa, S., MacMahon, H., & Doi, K. (2002) · Medical Physics · doi:10.1118/1.1469630 · Cited by 69
Self-citationComputer-Aided Diagnosis in Thoracic CT
Li, Q., Li, F., Suzuki, K., Shiraishi, J., Abé, H., Engelmann, R. M., Nie, Y., MacMahon, H., & Doi, K. (2005) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2005.07.001 · Cited by 67
Self-citationComputer-Aided Detection and Diagnosis at the Start of the Third Millennium
Erickson, B. J., & Bartholmai, B. J. (2002) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-002-0011-x · Cited by 66
Arimura, H., Li, Q., Korogi, Y., Hirai, T., Katsuragawa, S., Yamashita, Y., Tsuchiya, K., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2163389 · Cited by 66
Self-citationNakamori, N., Doi, K., Sabeti, V., & MacMahon, H. (1990) · Medical Physics · doi:10.1118/1.596513 · Cited by 66
Self-citationLoo, L. N., Doi, K., & Metz, C. E. (1985) · Medical Physics · doi:10.1118/1.595775 · Cited by 63
Self-citationOverview on research and development of computer-aided diagnostic schemes
Doi, K. (2004) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2004.02.006 · Cited by 63
Self-citationComputer-aided diagnosis for detection of interstitial opacities on chest radiographs.
Monnier‐Cholley, L., MacMahon, H., Katsuragawa, S., Morishita, J., Ishida, T., & Doi, K. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.6.9843307 · Cited by 61
Self-citationImproved Detection of Lung Nodules by Using a Temporal Subtraction Technique
Kakeda, S., Nakamura, K., Kamada, K., Watanabe, H., Nakata, H., Katsuragawa, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2241010719 · Cited by 61
Self-citationGiger, M. L., Doi, K., & Fujita, H. (1986) · Medical Physics · doi:10.1118/1.595937 · Cited by 60
Self-citationSanada, S., Doi, K., & MacMahon, H. (1992) · Medical Physics · doi:10.1118/1.596790 · Cited by 58
Self-citationSpiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms
Preda, L., Gaetani, P., y Baena, R. R., Maggio, E. M. D., Fianza, A. L., Dore, R., Fulle, I., Solcia, M., Cecchini, A., Infuso, L., et al. (1998) · European Radiology · doi:10.1007/s003300050465 · Cited by 55
Hirai, T., Korogi, Y., Arimura, H., Katsuragawa, S., Kitajima, M., Yamura, M., Yamashita, Y., & Doi, K. (2005) · Radiology · doi:10.1148/radiol.2372041734 · Cited by 54
Self-citationComputed assisted detection of interval breast cancers
Moberg, K., Bjurstam, N., Wilczek, B., Rostgård-Christensen, L., Egge, E., & Muren, C. (2001) · European Journal of Radiology · doi:10.1016/s0720-048x(01)00291-1 · Cited by 52
Giger, M. L., & Doi, K. (1985) · Medical Physics · doi:10.1118/1.595708 · Cited by 48
Self-citationFujita, H., Doi, K., Fencil, L. E., & Chua, K. G. (1987) · Medical Physics · doi:10.1118/1.596066 · Cited by 48
Self-citationAttempts to Use Computers as Diagnostic Aids in Medical Decision Making: A Thirty-Year Experience
Engle, R. L. (1992) · Perspectives in biology and medicine · doi:10.1353/pbm.1992.0011 · Cited by 47
Improved contralateral subtraction images by use of elastic matching technique
Li, Q., Katsuragawa, S., & Doi, K. (2000) · Medical Physics · doi:10.1118/1.1287112 · Cited by 47
Self-citationDoi, K., Giger, M. L., MacMahon, H., Hoffmann, K. R., Nishikawa, R. M., Schmidt, R. A., Chua, K. G., Katsuragawa, S., Nakamori, N., & Sanada, S. (1992) · PubMed · Cited by 44
Self-citationByers, T., Barrera, E., Fontham, E. T. H., Newman, L. A., Runowicz, C. D., Sener, S. F., Thun, M. J., Winborn, S., & Wender, R. C. (2006) · Cancer · doi:10.1002/cncr.21990 · Cited by 44
Effect of Heart-Size Parameters Computed from Digital Chest Radiographs on Detection of Cardiomegaly
Nakamori, N., Doi, K., MacMahon, H., Sasaki, Y., & Montner, S. M. (1991) · Investigative Radiology · doi:10.1097/00004424-199106000-00008 · Cited by 42
Self-citationContrast Gradient and the Detection of Lung Nodules
Kundel, H. L., Révész, G., & Toto, L. C. (1979) · Investigative Radiology · doi:10.1097/00004424-197901000-00004 · Cited by 39
Hoffmann, K. R., Doi, K., Chan, H., Fencil, L. E., Fujita, H., & Muraki, A. S. (1986) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.975409 · Cited by 38
Self-citationMuramatsu, C., Li, Q., Schmidt, R. A., Suzuki, K., Shiraishi, J., Newstead, G. M., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2266280 · Cited by 37
Self-citationComputer-aided diagnosis in chest radiology
Abé, H., MacMahon, H., Shiraishi, J., Li, Q., Engelmann, R. M., & Doi, K. (2004) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2004.02.004 · Cited by 35
Self-citationHigh quality digital radiographic images
Ishida, M., Frank, P. H., Doi, K., & Lehr, J. L. (1983) · Radiographics · doi:10.1148/radiographics.3.2.325 · Cited by 35
Self-citationKasai, S., Li, F., Shiraishi, J., Li, Q., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2364053 · Cited by 33
Self-citationShiraishi, J., Li, Q., Appelbaum, D., Pu, Y., & Doi, K. (2006) · Medical Physics · doi:10.1118/1.2401044 · Cited by 33
Self-citationKakeda, S., Kamada, K., Hatakeyama, Y., Aoki, T., Korogi, Y., Katsuragawa, S., & Doi, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.1270 · Cited by 30
Self-citationDevelopment Of A New Digital Radiographic Image Processing System
Ishida, M., Kato, H., Doi, K., & Frank, P. H. (1982) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.933805 · Cited by 29
Self-citationNishikawa, R. M., Doi, K., Giger, M. L., Schmidt, R. A., Vyborny, C. J., Monnier‐Cholley, L., Papaioannou, J., & Lu, P. (1995) · Radiographics · doi:10.1148/radiographics.15.2.7761647 · Cited by 29
Self-citationFujita, H., Doi, K., Giger, M. L., & Chan, H. (1986) · Medical Physics · doi:10.1118/1.595932 · Cited by 28
Self-citationShiraishi, J., Li, F., & Doi, K. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.09.057 · Cited by 27
Self-citationOhara, K., Chan, H., Doi, K., Giger, M. L., & Fujita, H. (1986) · Medical Physics · doi:10.1118/1.595918 · Cited by 25
Self-citationThe Lateral Radiograph for Early Diagnosis of Lung Cancer
Forrest, J. V., & Sagel, S. S. (1979) · Radiology · doi:10.1148/131.2.309 · Cited by 24
Radiologic contributions to cancer management. Bone metastases
Kagan, A., Bassett, L. W., Steckel, R., & Gold, R. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.2.305 · Cited by 24
Computerized Detection Of Lung Nodules In Digital Chest Radiographs
Giger, M. L., Doi, K., MacMahon, H., Dwyer, S. J., & Schneider, R. H. (1987) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.967022 · Cited by 23
Self-citationComputer-Aided Detection in Diagnostic Mammography: Detection of Clinically Unsuspected Cancers
Butler, S. A., Gabbay, R. J., Kass, D. A., Siedler, D. E., O′Shaughnessy, K. F., & Castellino, R. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.5.1831511 · Cited by 22
Rankin, S. (2005) · Surgery (Oxford) · doi:10.1383/surg.23.5.162.65500 · Cited by 21
Kume, Y., Doi, K., Ohara, K., & Giger, M. L. (1986) · Medical Physics · doi:10.1118/1.595808 · Cited by 21
Self-citationComputer-aided diagnosis in mammography
Doi, K. (2000) · Medical Entomology and Zoology · Cited by 18
Self-citationNishikawa, R. M., Haldemann, R., Papaioannou, J., Giger, M. L., Lu, P., Schmidt, R. A., Wolverton, D., Bick, U., & Doi, K. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.208732 · Cited by 18
Self-citationMacMahon, H., Vyborny, C. J., Sabeti, V., Metz, C. E., & Doi, K. (1985) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.949500 · Cited by 17
Self-citationTala, E. (1967) · PubMed · Cited by 17
Hoffmann, K. R. (1986) · Medical Entomology and Zoology · Cited by 17
Valutazione degli aneurismi cerebrali con Angio-RM
Aprile, I., Biasizzo, E., Lavaroni, A., Budai, R., Iaiza, F., Janes, P. P., & Fabris, G. (1996) · Rivista di Neuroradiologia · doi:10.1177/197140099600900505 · Cited by 16
Lung cancer screening with spiral CT: toward a working strategy.
Warner, E. E., & Mulshine, J. L. (2004) · PubMed · Cited by 12
Doi, K., MacMahon, H., Giger, M. L., & Hoffmann, K. R. (1999) · Medical Entomology and Zoology · Cited by 10
Self-citationGiger, M. L., Ohara, K., & Doi, K. (1986) · Medical Physics · doi:10.1118/1.595919 · Cited by 10
Self-citationMacMahon, H., Vyborny, C. J., Powell, G. F., Doi, K., & Metz, C. E. (1984) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.943193 · Cited by 7
Self-citationIshida, T., Katsuragawa, S., Nakamura, K., Ashizawa, K., MacMahon, H., & Doi, K. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.467096 · Cited by 7
Self-citationDevelopment of computerized method for detection of vertebral fractures on lateral chest radiographs
Kasai, S., Li, F., Shiraishi, J., Li, Q., Nie, Y., & Doi, K. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.653265 · Cited by 4
Self-citation
Research works printed but not linked: 1
- Doi K, Chan H-P, Giger ML. Method and system for enhancement and detection of abnormal anatomic regions in a digital image. United States Patent 4,907,156 (1990).
Cited by
Sorted by citations
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Histopathological Image Analysis: A Review
Gurcan, M. N., Boucheron, L. E., Can, A., Madabhushi, A., Rajpoot, N. M., & Yener, B. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2034865 · Cited by 2,052
Recent advances and clinical applications of deep learning in medical image analysis
Chen, X., Wang, X., Zhang, K., Fung, K.-M. A., Thai, T., Moore, K. N., Mannel, R. S., Liu, H., Zheng, B., & Qiu, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102444 · Cited by 1,180
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,131
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
Metadata
- Authors
- Doi, K.
- Affiliations
- University of Chicago (US)
- Corresponding author
- Doi, Kunio
- Venue
- Computerized Medical Imaging and Graphics
- Publisher
- Elsevier BV
- Published
- 2007-06
- Volume
- 31
- Issue
- 4-5
- Pages
- 198-211
- ISSN
- 0730-4862 (ISSN-L)
- 0895-6111
- PMC
- PMC1955762
- OpenAlex
- W2141619730
- Cited by
- 1,855
- References
- 157
- Citations by year
- 2026: 72 · 2025: 108 · 2024: 128 · 2023: 128 · 2022: 195 · 2021: 153 · 2020: 161 · 2019: 133 · 2018: 129 · 2017: 97 · 2016: 80 · 2015: 75 · 2014: 71 · 2013: 76 · 2012: 67
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Computerized Medical Imaging and Graphics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Radiological Society of North America
- University of Chicago
- Hologic
- U.S. Public Health Service
- National Cancer Institute (CA98119, CA 62625, R01CA062625, R01CA098119)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- computer-aided diagnosis, diagnostic imaging, PACS, second opinion, breast cancer detection, mammography, lung nodule detection, vertebral fracture detection, osteoporosis, intracranial aneurysm detection, bone scintigraphy, interstitial lung disease, differential diagnosis, image similarity search, history of CAD
- MeSH terms
- Diagnosis, Computer-Assisted, Diagnostic Imaging, Forecasting, Humans, Radiology Information Systems, United States, History, 20th Century
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review