The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Robust optic disc and cup segmentation with deep learning for glaucoma detection
Abstract
Glaucoma is rated as the leading cause of irreversible vision loss worldwide. Early detection of glaucoma is important for providing timely treatment and minimizing the vision loss. In this paper, we developed a robust segmentation method for optic disc and cup segmentation using a modified U-Net architecture, which combines the widely adopted pre-trained ResNet-34 model as encoding layers with classical U-Net decoding layers. The model was trained on the newly available RIGA dataset, and achieved an average dice value of 97.31% for disc segmentation and 87.61% for cup segmentation, comparable to that of the experts' performance for optic disc/cup segmentation and Cup-Disc-Ratio (CDR) calculation on a reserved RIGA dataset. When tested on DRISHTI-GS and RIM-ONE dataset without re-training or fine-tuning, the model achieved comparable performance to that of the state-of-the-art in literature. We have also fine-tuned the model on two databases, which achieves an average disc dice value of 97.38% and cup dice value of 88.77% for DRISHTI-GS test set, disc dice of 96.10% and cup dice of 84.45% for RIM-ONE database, which is the state-of-the-art performance on both databases in terms of cup dice and disc dice value. The advantage of the proposed method is the combination of the pre-trained ResNet and U-Net, which avoids training the network from scratch, thereby enabling fast network training with less epochs, thus further avoids over-fitting and achieves robust performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
SGDR: Stochastic Gradient Descent with Warm Restarts
Loshchilov, I., & Hutter, F. (2016) · arXiv · doi:10.48550/arxiv.1608.03983 · Cited by 5,309
Cited by
U-Net and Its Variants for Medical Image Segmentation: A Review of Theory and Applications
Siddique, N., Paheding, S., Elkin, C. P., & Devabhaktuni, V. (2021) · IEEE Access · doi:10.1109/access.2021.3086020 · Cited by 1,960
Medical SAM adapter: Adapting segment anything model for medical image segmentation
Wu, J., Wang, Z., Hong, M., Ji, W., Fu, H., Xu, Y., Xu, M., & Jin, Y. (2025) · Medical Image Analysis · doi:10.1016/j.media.2025.103547 · Cited by 677
MedSegDiff-V2: Diffusion-Based Medical Image Segmentation with Transformer
Wu, J., Ji, W., Fu, H., Xu, M., Jin, Y., & Xu, Y. (2024) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v38i6.28418 · Cited by 275
EEG-Based Pathology Detection for Home Health Monitoring
Muhammad, G., Hossain, M. S., & Kumar, N. (2021) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2020.3020654 · Cited by 148
Modeling annotator preference and stochastic annotation error for medical image segmentation
Liao, Z., Hu, S., Xie, Y., & Xia, Y. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103028 · Cited by 35
Metadata
- Authors
- Yu, S., Xiao, D., Frost, S., & Kanagasingam, Y.
- Venue
- Computerized Medical Imaging and Graphics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 74
- Pages
- 61-71
- ISSN
- 0730-4862 (ISSN-L)
- 0895-6111
- OpenAlex
- W2935464137
- Cited by
- 223
- References
- 2
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.