Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Fully automatic knee osteoarthritis severity grading using deep neural networks with a novel ordinal loss

Open access
Chen, Pingjun, Gao, Linlin, Shi, Xiaoshuang, Allen, Kyle, Yang, Lin·2019·Computerized Medical Imaging and Graphics

Abstract

Knee osteoarthritis (OA) is one major cause of activity limitation and physical disability in older adults. Early detection and intervention can help slow down the OA degeneration. Physicians’ grading based on visual inspection is subjective, varied across interpreters, and highly relied on their experience. In this paper, we successively apply two deep convolutional neural networks (CNN) to automatically measure the knee OA severity, as assessed by the Kellgren-Lawrence (KL) grading system. Firstly, considering the size of knee joints distributed in X-ray images with small variability, we detect knee joints using a customized one-stage YOLOv2 network. Secondly, we fine-tune the most popular CNN models, including variants of ResNet, VGG, and DenseNet as well as InceptionV3, to classify the detected knee joint images with a novel adjustable ordinal loss. To be specific, motivated by the ordinal nature of the knee KL grading task, we assign higher penalty to misclassification with larger distance between the predicted KL grade and the real KL grade. The baseline X-ray images from the Osteoarthritis Initiative (OAI) dataset are used for evaluation. On the knee joint detection, we achieve mean Jaccard index of 0.858 and recall of 92.2% under the Jaccard index threshold of 0.75. On the knee KL grading task, the fine-tuned VGG-19 model with the proposed ordinal loss obtains the best classification accuracy of 69.7% and mean absolute error (MAE) of 0.344. Both knee joint detection and knee KL grading achieve state-of-the-art performance. The code, dataset, and models are released at https://github.com/PingjunChen/KneeAnalysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compmedimag.2019.06.002

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 309

Metadata

Authors
Chen, P., Gao, L., Shi, X., Allen, K., & Yang, L.
Venue
Computerized Medical Imaging and Graphics
Publisher
Elsevier BV
Published
2019-07
Volume
75
Pages
84-92
ISSN
  • 0730-4862 (ISSN-L)
  • 0895-6111
OpenAlex
W2951269226
Cited by
309
References
34
FWCI
5.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully automatic knee osteoarthritis severity grading using deep neural networks with a novel ordinal loss. https://app.cochat.ai/papers/10.1016/j.compmedimag.2019.06.002
The paper
Chen, P., Gao, L., Shi, X., Allen, K., & Yang, L. (2019). Fully automatic knee osteoarthritis severity grading using deep neural networks with a novel ordinal loss. Computerized Medical Imaging and Graphics. https://doi.org/10.1016/j.compmedimag.2019.06.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.