The DOI matches its Crossref record.
3D reduced graphene oxide/FeNi3-ionic liquid nanocomposite modified sensor; an electrical synergic effect for development of tert-butylhydroquinone and folic acid sensor
Abstract
Abstract This paper reports an electroanalytical sensor developed based on reduced graphene oxide/FeNi3 (FeNi3/rGO)-ionic liquid (n-hexyl-3-methylimidazolium hexafluoro phosphate (HMPF6) carbon paste electrode (CPE) for determining the antioxidant additive tertbutylhydroquinone (TBHQ) in the presence of folic acid. The FeNi3/rGO synthesized by hydrothermal strategy and characterized by X-ray diffraction (XRD) and FESEM methods. The electrochemical response were found to be linearly symmetrical to TBHQ and folic acid concentrations in the range from 0.05 to 900 μM and 0.6–1100 μM with detection limits of 10.0 nM and 0.1 μM, respectively. The FeNi3/rGO/HMPF6/CPE showed high-quality for determination of TBHQ in the presence of folic acid in the real samples with the separation potential ∼600 mV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tuning of metal oxides photocatalytic performance using Ag nanoparticles integration
Karimi-Maleh, H., Kumar, B. G., Rajendran, S., Qin, J., Vadivel, S., Durgalakshmi, D., Gracia, F., Soto-Moscoso, M., Orooji, Y., & Karimi, F. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2020.113588 · Cited by 429
Self-citationRecent advances in carbon nanomaterials-based electrochemical sensors for food azo dyes detection
Karimi-Maleh, H., Beitollahi, H., Senthil Kumar, P., Tajik, S., Mohammadzadeh Jahani, P., Karimi, F., Karaman, C., Vasseghian, Y., Baghayeri, M., Rouhi, J., et al. (2022) · Food and Chemical Toxicology · doi:10.1016/j.fct.2022.112961 · Cited by 367
Self-citationBasavapura Ravikumar, S., Prasanna, S. B., Shanthappa, N. S., Dwarakanath, S. C., Shivamurthy, S. A., Shadakshari, S., Shanthakumar, K. C., Al-lohedan, H. A., & Karnan, M. (2023) · ACS Omega · doi:10.1021/acsomega.3c06254 · Cited by 16
Metadata
- Authors
- Tahernejad-Javazmi, F., Shabani-Nooshabadi, M., & Karimi-Maleh, H.
- Venue
- Composites Part B: Engineering
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 172
- Pages
- 666-670
- ISSN
- 1359-8368 (ISSN-L)
- OpenAlex
- W2943998690
- Cited by
- 331
- References
- 0
- FWCI
- 24.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D reduced graphene oxide/FeNi3-ionic liquid nanocomposite modified sensor; an electrical synergic effect for development of tert-butylhydroquinone and folic acid sensor. https://app.cochat.ai/papers/10.1016/j.compositesb.2019.05.065
- The paper
- Tahernejad-Javazmi, F., Shabani-Nooshabadi, M., & Karimi-Maleh, H. (2019). 3D reduced graphene oxide/FeNi3-ionic liquid nanocomposite modified sensor; an electrical synergic effect for development of tert-butylhydroquinone and folic acid sensor. Composites Part B: Engineering. https://doi.org/10.1016/j.compositesb.2019.05.065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.