The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Flexible, conductive, and highly pressure-sensitive graphene-polyimide foam for pressure sensor application
Abstract
Abstract Three-dimensional porous graphene foams have received increasing attention in the fields of sensors, flexible conductors, and energy storage. Mechanical stability, flexibility, and electrical conductivity are prerequisites for materials used in these fields. In this paper, novel polyimide-based graphene foam was prepared by dip-coating a polyimide foam template followed by chemical reduction and thermal reduction. The prepared foam displayed excellent mechanical stability and flexibility (elastic modulus: ∼5 kPa). The synergistic effects of chemical and thermal reduction led to a foam with high electrical conductivity of ∼0.4 S m−1. By controlling the dip-coating times, the foam achieved a high pressure sensitivity of 0.36 kPa−1. Experiments show that the prepared foam can be used as effective pressure sensor to measure heartbeat, joint activity, and airflow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Shin, S.-H., Ji, S., Choi, S., Pyo, K.-H., Wan An, B., Park, J., Kim, J., Kim, J.-Y., Lee, K.-S., Kwon, S.-Y., et al. (2017) · Nature Communications · doi:10.1038/ncomms14950 · Cited by 203
Cited by
Chen, X., Liu, H., Zheng, Y., Zhai, Y., Liu, X., Liu, C., Mi, L., Guo, Z., & Shen, C. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14688 · Cited by 357
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Zhang, M., Liu, S., Liu, S., Jia, G., Zhan, P., Liu, C., Shen, C., & Liu, H. (2025) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-01157-1 · Cited by 23
Metadata
- Authors
- Yang, J., Ye, Y., Li, X., Lü, X., & Chen, R.
- Venue
- Composites Science and Technology
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 164
- Pages
- 187-194
- ISSN
- 0266-3538 (ISSN-L)
- OpenAlex
- W2805847862
- Cited by
- 165
- References
- 4
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible, conductive, and highly pressure-sensitive graphene-polyimide foam for pressure sensor application. https://app.cochat.ai/papers/10.1016/j.compscitech.2018.05.044
- The paper
- Yang, J., Ye, Y., Li, X., Lü, X., & Chen, R. (2018). Flexible, conductive, and highly pressure-sensitive graphene-polyimide foam for pressure sensor application. Composites Science and Technology. https://doi.org/10.1016/j.compscitech.2018.05.044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.