The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Compressible and Robust Polyimide/Carbon Nanotube Composite Aerogel for High-Performance Wearable Pressure Sensor
Abstract
Wearable pressure sensors are in great demand with the rapid development of intelligent electronic devices. However, it is still a huge challenge to obtain high-performance pressure sensors with high sensitivity, wide response range, and low detection limit simultaneously. Here, a polyimide (PI)/carbon nanotube (CNT) composite aerogel with the merits of superelastic, high porosity, robust, and high-temperature resistance was successfully prepared through the freeze drying plus thermal imidization process. Benefiting from the strong chemical interactions between PI and CNT and stable electrical property, the composite aerogel exhibits versatile and superior brilliant sensing performance, which includes wide sensing range (80% strain, 61 kPa), ultrahigh sensitivity (11.28 kPa –1 ), ultralow detection limit (0.1% strain, <10 Pa), fast response time (50 ms) and recovery time (70 ms), remarkable long-term stability (1000 cycles), and exceptional detection ability toward different deformations (compression, distortion, and bending). Furthermore, the composite aerogel also shows stable sensing performance after annealing under different high temperatures and good thermal insulation property, making it workable in various harsh environments. As a result, the composite aerogel is suitable for the full-range human motion detection (including airflow, pulse, vocal cord vibration, and human movement) and precise detection of the pressure distribution when it is assembled into E-skin, demonstrating its great potential to serve as a high-performance wearable pressure sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Fan, W., Huang, Y., Zhang, C., & Liu, T. (2015) · RSC Advances · doi:10.1039/c4ra13015d · Cited by 112
Cited by
Microengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Wang, L., Zhang, M., Yang, B., Tan, J., & Ding, X. (2020) · ACS Nano · doi:10.1021/acsnano.0c04888 · Cited by 409
Yin, R., Yang, S., Li, Q., Zhang, S., Liu, H., Han, J., Liu, C., & Shen, C. (2020) · Science Bulletin · doi:10.1016/j.scib.2020.02.020 · Cited by 322
Self-citationYang, W., Liu, H., Du, H., Zhang, M., Wang, C., Yin, R., Pan, C., Liu, C., & Shen, C. (2023) · Science China Materials · doi:10.1007/s40843-022-2418-1 · Cited by 128
Self-citationYang, W., Liu, S., Wang, Z., Liu, H., Pan, C., Liu, C., & Shen, C. (2024) · Nano Energy · doi:10.1016/j.nanoen.2024.109799 · Cited by 95
Self-citation
Metadata
- Authors
- Chen, X., Liu, H., Zheng, Y., Zhai, Y., Liu, X., Liu, C., Mi, L., Guo, Z., & Shen, C.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-10-16
- Volume
- 11
- Issue
- 45
- Pages
- 42594-42606
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2980548960
- Cited by
- 357
- References
- 1
- FWCI
- 14.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Compressible and Robust Polyimide/Carbon Nanotube Composite Aerogel for High-Performance Wearable Pressure Sensor. https://app.cochat.ai/papers/10.1021/acsami.9b14688
- The paper
- Chen, X., Liu, H., Zheng, Y., Zhai, Y., Liu, X., Liu, C., Mi, L., Guo, Z., & Shen, C. (2019). Highly Compressible and Robust Polyimide/Carbon Nanotube Composite Aerogel for High-Performance Wearable Pressure Sensor. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b14688
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.