The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self-healing, anti-freezing, adhesive and remoldable hydrogel sensor with ion-liquid metal dual conductivity for biomimetic skin
Abstract
Abstract Flexible wearable sensors assembled from conductive hydrogels have received great attention due to their wide application in human-machine interfaces, medical and healthcare detection. However, the traditional conductive gel needs to be attached to the application surface with external force, and only respond to the single strain stimulus. Moreover, due to the existence of water, ordinary hydrogels cannot work at below zero temperatures, which severely limits the application of hydrogel-based flexible electronic devices. The flexible wearable epidermal sensors assembled by ultra-sensitive polyvinyl alcohol-tannic acid-eutectic gallium-indium (PVA-TA-EGaIn) hydrogels with adhesiveness, rapid self-healing, high electrical conductivity and mechanical properties, and temperature sensitivity. The rigid conductive hydrogel prepared by freeze-thaw cycles shows outstanding tensile/compressive strength (1.13 MPa/4.59 MPa) and toughness (1.9 MJ/m3), and reveals excellent fatigue resistance. It also exhibited high conductivity (3.63 S m−1) and strain sensitivity (gauge factor = 2.59). In addition, the hydrogels maintained good flexibility and conductivity at −10 °C. Besides, the PVA-TA-EGaIn hydrogels shows remoldability, which greatly prolongs the service life of the gel. The composite hydrogels show the potential of building the next generation of multifunctional hydrogel-based flexible wearable sensors in human motion monitoring, voice recognition and medical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Wu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225
Cited by
Tannic acid: a versatile polyphenol for design of biomedical hydrogels
Jafari, H., Ghaffari-Bohlouli, P., Niknezhad, S. V., Abedi, A., Izadifar, Z., Mohammadinejad, R., Varma, R. S., & Shavandi, A. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb01056a · Cited by 329
Smart Eutectic Gallium–Indium: From Properties to Applications
Zhao, Z., Soni, S., Lee, T., Nijhuis, C. A., & Xiang, D. (2023) · Advanced Materials · doi:10.1002/adma.202203391 · Cited by 300
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Recent advances in tannic acid-based gels: Design, properties, and applications
Tang, Z., Chowdhury, I. F., Yang, J., Li, S., Mondal, A. K., & Wu, H. (2025) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2025.103425 · Cited by 70
Metadata
- Authors
- Zhou, Z., Qian, C., & Yuan, W.
- Venue
- Composites Science and Technology
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 203
- Pages
- 108608
- ISSN
- 0266-3538 (ISSN-L)
- OpenAlex
- W3110879792
- Cited by
- 230
- References
- 2
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.