The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Methods for measuring pH in concrete: A review
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neville, A. M. (1968) · Virtual Defense Library (Ministerio de Defensa) · Cited by 5,444
Influence of limestone on the hydration of Portland cements
Lothenbach, B., Le Saout, G., Gallucci, E., & Scrivener, K. (2008) · Cement and Concrete Research · doi:10.1016/j.cemconres.2008.01.002 · Cited by 1,699
The Measurement, Instrumentation and Sensors Handbook
Webster, J. G. (1998) · CRC Press eBooks · doi:10.1201/9781003040019 · Cited by 1,029
Thermodynamic modelling of the hydration of Portland cement
Lothenbach, B., & Winnefeld, F. (2006) · Cement and Concrete Research · doi:10.1016/j.cemconres.2005.03.001 · Cited by 903
Lothenbach, B., Winnefeld, F., Alder, C., Wieland, E., & Lunk, P. (2007) · Cement and Concrete Research · doi:10.1016/j.cemconres.2006.11.016 · Cited by 811
Expression and analysis of pore fluids from hardened cement pastes and mortars
Barneyback, R. S., & Diamond, S. (1981) · Cement and Concrete Research · doi:10.1016/0008-8846(81)90069-7 · Cited by 604
Hydration of Portland cement with high replacement by siliceous fly ash
Deschner, F., Winnefeld, F., Lothenbach, B., Seufert, S., Schwesig, P., Dittrich, S., Goetz-Neunhoeffer, F., & Neubauer, J. (2012) · Cement and Concrete Research · doi:10.1016/j.cemconres.2012.06.009 · Cited by 544
Hesse, C., Goetz‐Neunhoeffer, F., & Neubauer, J. (2010) · Cement and Concrete Research · doi:10.1016/j.cemconres.2010.09.014 · Cited by 372
A flexible pH sensor based on the iridium oxide sensing film
Huang, W.-D., Cao, H., Deb, S., Chiao, M., & Chiao, J. C. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.05.016 · Cited by 361
Pore solution composition and chloride binding capacity of silica-fume cement pastes
Page, C. L., & Vennesland, Ø. (1983) · Materials and Structures · doi:10.1007/bf02474863 · Cited by 347
Cited by
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Plusquellec, G., Geiker, M. R., Lindgård, J., Duchesne, J., Fournier, B., & De Weerdt, K. (2017) · Cement and Concrete Research · doi:10.1016/j.cemconres.2017.03.002 · Cited by 354
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
A review on five key sensors for monitoring of concrete structures
Taheri, S. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.01.172 · Cited by 311
Metadata
- Authors
- Behnood, A., Van Tittelboom, K., & De Belie, N.
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 105
- Pages
- 176-188
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W2212188112
- Cited by
- 262
- References
- 36
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for measuring pH in concrete: A review. https://app.cochat.ai/papers/10.1016/j.conbuildmat.2015.12.032
- The paper
- Behnood, A., Van Tittelboom, K., & De Belie, N. (2016). Methods for measuring pH in concrete: A review. Construction and Building Materials. https://doi.org/10.1016/j.conbuildmat.2015.12.032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.