Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 186

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Corrosion resistance evaluation of rebars with various primers and coatings in concrete modified with different additives

Afshar, Alireza, Jahandari, Soheil, Rasekh, Haleh, Shariati, Mahdi, Afshar, Abdollah, Shokrgozar, Ali · 2020 · Construction and Building Materials

Abstract

Abstract Corrosion of steel rebars in concrete can reduce the durability of concrete structures in coastal environments. The corrosion rate of these concrete structures can be reduced by using suitable concrete additives and coating on rebars. This paper investigates the corrosion resistance of steel rebars by the addition of pozzolanic materials including fly ash, silica fume, polypropylene fibers, and industrial 2-dimethylaminoethanol (FerroGard 901) inhibitors to the concrete mixture. Three different types of rebars including mild steel rebar st37, and two stainless steel reinforcements, AISI 304 and AISI 316, were used. Various types of primer and coating including alkyd based primer, hot-dip galvanized coatings, alkyd top coating, zinc-rich epoxy primer, polyamide epoxy primer, polyamide epoxy top coating, polyurethane coatings, double layer of epoxy primer and alkyd top coating, and double layer of alkyd primer and alkyd top coating were applied on steel rebars to investigate the effect of coating type on the corrosion resistance of steel rebars in concrete. Polarization tests, electrochemical impedance spectroscopy, compressive strength and color adhesion tests were conducted. The best reinforced concrete mix design for corrosion resistance was the one including the rebar with zinc-rich epoxy primer and 25% fly ash, 10% silica fume, and 3% FerroGard 901 inhibitors by cementitious material weight. Polyurethane was the best coating due to the highest strength and the lowest corrosion rate. Alkyd primer was the weakest coating, although it was the most economical coating system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.conbuildmat.2020.120034

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 186

Metadata

Authors
Afshar, A., Jahandari, S., Rasekh, H., Shariati, M., Afshar, A., & Shokrgozar, A.
Venue
Construction and Building Materials
Publisher
Elsevier BV
Published
2020-11
Volume
262
Pages
120034
ISSN
0950-0618 (ISSN-L)
OpenAlex
W3041824023
Cited by
186
References
2
FWCI
17.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corrosion resistance evaluation of rebars with various primers and coatings in concrete modified with different additives. https://app.cochat.ai/papers/10.1016/j.conbuildmat.2020.120034
The paper
Afshar, A., Jahandari, S., Rasekh, H., Shariati, M., Afshar, A., & Shokrgozar, A. (2020). Corrosion resistance evaluation of rebars with various primers and coatings in concrete modified with different additives. Construction and Building Materials. https://doi.org/10.1016/j.conbuildmat.2020.120034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.