The DOI matches its Crossref record; 162 of the 162 references it cites were found in a registry or an index.
Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring
Open accessAbstract
Abstract Steel corrosion is the main cause of deterioration of reinforced concrete (RC) structures. We provide an up-to-date review on corrosion mechanisms and recent advances in electrical methods for corrosion monitoring. When assessing corrosion mechanism, the inherent heterogeneity of RC structures and the significant effect of environmental factors remain major issues in data interpretations. The steel surface condition and local inhomogeneities at the steel–concrete interface appear to have an important effect on corrosion initiation. Considering uniform corrosion in atmospherically exposed RC structures, the two main influencing factors of the corrosion process are the water content and the pore structure at the steel–concrete interface. However, irrespective of the depassivation mechanism, i.e. carbonation or chloride-induced corrosion, non-uniform corrosion is expected to be the main process for RC structures due to local variations in environmental exposure or the presence of interconnected rebars with different properties. Future studies may then be focused on their effect on macrocell corrosion to gain further insights in the corrosion mechanisms of RC structures. Concerning corrosion monitoring using electrical methods, the half-cell potential technique with potential mapping is accurate for locating areas with a high corrosion risk. Recent developments in the measurement of concrete resistivity have shown that the use of electrical resistivity tomography allows to consider appropriately the inherent heterogeneity of concrete and provides more insights on transport phenomena (e.g. water and salts ingress) in the material. Nevertheless, during the corrosion propagation stage, the polarization resistance remains the most important parameter to be determined as it provides quantitative information of the corrosion rate. If conventional three-electrode configuration methods can supply an accurate determination in the case of uniform corrosion, they often fail in the case of macrocell corrosion in field experiments. Recent advances have shown that a four-electrode configuration without any connection to the rebar can rather be used for the non-destructive testing and evaluation of corrosion. If studies are still required to quantify the corrosion rate, this method appears sensitive to localized corrosion and thus more suitable to field investigations. Finally, the coupling of numerical simulations with complementary electrical and other non-destructive testing methods is essential for consolidating the results to provide a better diagnosis of the service life of RC structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Iron Oxides: Structure, Properties, Reactions, Occurences and Uses
Cornell, R. M., & Schwertmann, U. (2003) · doi:10.1002/3527602097 · Cited by 4,422
Stern, M., & Geaby, A. L. (1957) · Journal of The Electrochemical Society · doi:10.1149/1.2428496 · Cited by 3,876
Supplementary cementitious materials
Lothenbach, B., Scrivener, K., & Hooton, R. D. (2011) · Cement and Concrete Research · doi:10.1016/j.cemconres.2010.12.001 · Cited by 3,406
Principles and prevention of corrosion
Walker, R. (1993) · Materials & Design · doi:10.1016/0261-3069(93)90066-5 · Cited by 2,427
Mechanisms of cement hydration
Bullard, J. W., Jennings, H. M., Livingston, R. A., Nonat, A., Scherer, G. W., Schweitzer, J. S., Scrivener, K. L., & Thomas, J. J. (2011) · Cement and Concrete Research · doi:10.1016/j.cemconres.2010.09.011 · Cited by 2,237
Principles and prevention of corrosion
Jones, D. A. (1991) · Cited by 2,104
Global CO 2 emissions from cement production
Andrew, R. M. (2018) · Earth System Science Data · doi:10.5194/essd-10-195-2018 · Cited by 1,583
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
The Point Defect Model for the Passive State
Macdonald, D. D. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2069096 · Cited by 1,574
Critical chloride content in reinforced concrete — A review
Angst, U., Elsener, B., Larsen, C. K., & Vennesland, Ø. (2009) · Cement and Concrete Research · doi:10.1016/j.cemconres.2009.08.006 · Cited by 1,420
Cited by
Wasim, M., & Djukic, M. B. (2022) · Journal of Natural Gas Science and Engineering · doi:10.1016/j.jngse.2022.104467 · Cited by 347
Metadata
- Authors
- Rodrigues, R., Gaboreau, S., Gance, J., Ignatiadis, I., & Betelu, S.
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 269
- Pages
- 121240
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W3095796434
- Cited by
- 410
- References
- 162
- FWCI
- 20.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring. https://app.cochat.ai/papers/10.1016/j.conbuildmat.2020.121240
- The paper
- Rodrigues, R., Gaboreau, S., Gance, J., Ignatiadis, I., & Betelu, S. (2021). Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring. Construction and Building Materials. https://doi.org/10.1016/j.conbuildmat.2020.121240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.