Cited by 48Building Energy and Comfort OptimizationAdvanced Control Systems OptimizationIntegrated Energy Systems Optimization

MPC approaches for modulating air-to-water heat pumps in radiant-floor buildings

Rastegarpour, Soroush, Gros, Sebastien, Ferrarini, Luca·2020·Control Engineering Practice

Integrity signals

Registry

Crossref · 10.1016/j.conengprac.2019.104209

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Different from conventional linearization methods such as Taylor series and Carleman approaches, the linear system (13) is obtained without a concrete mathematical model and is effective in the whole set D_x, not only locally around equilibrium points.

    “Different from conventional linearization methods, such as Taylor series [29], [47] and Carleman approaches [48], the linear system (13) is obtained without concrete mathematical model. Besides, it is effective in the whole set D x , not only locally around equilibrium points.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rastegarpour, S., Gros, S., & Ferrarini, L.
Affiliations
Politecnico di Milano (IT)
Corresponding author
Ferrarini, Luca
Venue
Control Engineering Practice
Publisher
Elsevier BV
Published
2020-02
Volume
95
Pages
104209
ISSN
0967-0661 (ISSN-L)
OpenAlex
W2984627899
Cited by
48
References
34
Citations by year
2026: 6 · 2025: 5 · 2024: 9 · 2023: 5 · 2022: 10 · 2021: 7 · 2020: 6
FWCI
3.85
Type
journal article
Language
en
Open access
closed
Locations
  • Control Engineering Practice (publishedVersion)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
Keywords
model predictive control, air-to-water heat pump, radiant floor heating, nonlinear model predictive control, temperature control, water tanks, energy efficiency, thermal comfort, robustness analysis, heat pump efficiency, reference trajectory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review