Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index; none of the 27 sources its claims cite is checked for support yet.

Improved resolution in dipolar NMR spectra using constant time evolution PISEMA experiment

Open access
Gopinath, T., Veglia, Gianluigi · 2010 · Chemical Physics Letters

Abstract

The atomic structure of small molecules and polypeptides can be attained from anisotropic NMR parameters such as dipolar couplings (DC) and chemical shifts (CS). Separated local field experiments resolve DC and CS correlations into two dimensions. However, crowded NMR spectra represent a significant obstacle for the complete resolution of these anisotropic parameters. Using the PISEMA (Polarization Inversion Spin Exchange at the Magic Angle) experiment as a foundation, we designed new pulse schemes that use a constant time evolution in the dipolar (indirect) dimension to measure DC and CS correlations at high resolution. We demonstrated this approach on a 4-pentyl-4′-cyanobiphenyl (5CB) liquid crystal sample, achieving a resolution enhancement ranging from 30 to 60 % for the resonances in the dipolar dimension. These new experiments open the possibility of obtaining significant resolution enhancement for multidimensional NMR experiments carried out on oriented liquid crystalline samples as well as oriented membrane proteins.

Overview

CoChat Summary

TL;DR

The authors introduce constant-time (CT) evolution into PISEMA and sensitivity-enhanced PISEMA (SECT-PISEMA) to improve resolution in the dipolar dimension of separated local field NMR. On a 5CB liquid crystal sample, CT evolution enhanced dipolar resolution by 30–60%, and SECT-PISEMA narrowed lines by 100–250 Hz versus conventional PISEMA while improving sensitivity.

Key findings

  • CT-PISEMA and SECT-PISEMA use constant time evolution in the dipolar indirect dimension, implemented by refocusing the dipolar Hamiltonian in the doubly tilted rotating frame. For the 5CB liquid crystal, CT evolution reduced line widths with a resolution enhancement ranging from 30 to 60% across the spectrum.
  • In SECT-PISEMA, dipolar lines were narrowed by 100 to 250 Hz with respect to conventional PISEMA. The constant-time dipolar oscillations of CT- and SECT-PISEMA were less affected by relaxation than conventional PISEMA.
  • SECT-PISEMA sensitivity was ~10 to 30% higher than PISEMA except for carbons 1 and 1′, while the gain over CT-PISEMA ranged from 15 to 35%. The loss of sensitivity for CT-PISEMA was negligible for carbons 2′, 3′, and 4′.
  • The sine dipolar spectra showed a drastically reduced zero-frequency peak, making them useful for measuring small dipolar couplings often obliterated by truncation artifacts of the intense zero-frequency peak.

Methods

  • Pulse sequence design and theory: CT evolution was incorporated into PISEMA and SE-PISEMA; the dipolar Hamiltonian sign was inverted with 180° pulses, and SECT-PISEMA alternated the phase φ of a 90° pulse on the I spin between y and −y to detect cosine- and sine-modulated dipolar coherences.
  • Sample and acquisition: experiments used an oriented 4-pentyl-4′-cyanobiphenyl (5CB) liquid crystal sample on a 700 MHz VNMRS spectrometer at 25°C, with 10 ms acquisition time, 6 s recycle delay, and 5 ms CP contact time. Conventional PISEMA used 64 t1 increments, whereas CT-PISEMA and SECT-PISEMA used 21 t1 increments; SECT-PISEMA acquired two interleaved data sets with φ = y and −y.
  • Processing and analysis: data were processed with forward linear prediction of the t1 signal up to 128 points and a 90° phase-shifted sine bell window in F1 and F2; PISEMA and CT-PISEMA t1 dimensions were processed in real mode, while SECT-PISEMA used Rance-Kay mode. Resolution was assessed by comparing 1D dipolar cross-section line widths and signal decay in the indirect dimension.

Limitations

  • Stated: CT evolution reduces signal intensity, which can be exacerbated by relaxation effects for specific resonances; the CT period should be optimized with awareness of the relaxation properties of the system. For 5CB, fast relaxation of carbons 1, 3, and 4′ forced the total evolution time T to 1280 μs, corresponding to 21 increments.
  • Stated: the zero-frequency peak remains present, probably caused by pulse imperfections, though drastically reduced; sine-CT-PISEMA zero-frequency components are dispersive due to imaginary Fourier transformation, and the last trace was slightly distorted from pulse imperfection due to a large 13C offset (35 ppm for resonance 1′).
  • Stated/evident: resolution enhancement was demonstrated only on a 5CB liquid crystalline molecule; the authors anticipate a significant contribution for congested dipolar spectra of membrane proteins aligned in magnetically aligned lipid bicelles, but do not demonstrate that here. Evident: the study uses a single sample, field, and temperature, with no membrane-protein validation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.cplett.2010.05.078

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 15 Not checked · 31 Own results and interpretations

19 more claims

Create a free account to see all 46 claims and to verify the 20 references still open.

See all claims — free account
  • Probably not a substantial claim. 18
  • It may state two separate claims as one. 7

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 41 references

Research works printed but not linked: 5

  1. Gopinath, 2010, J. Phys. Chem. B
  2. Gopinath, 2010, J. Am. Chem. Soc.
  3. Bax, 1981, J. Magn. Reson., 44, 542
  4. Rance, 1984, J. Magn. Reson., 59, 250
  5. Vuister, 1992, J. Magn. Reson., 98, 428

Cited by

See all 10

Metadata

Authors
Gopinath, T., & Veglia, G.
Affiliations
University of Minnesota (US)
Corresponding author
Veglia, Gianluigi
Venue
Chemical Physics Letters
Publisher
Elsevier BV
Published
2010-07
Volume
494
Issue
1-3
Pages
104-110
ISSN
0009-2614 (ISSN-L)
OpenAlex
W2120631579
Cited by
10
References
41
Citations by year
2025: 1 · 2017: 1 · 2014: 1 · 2013: 3 · 2012: 2
FWCI
0.87
Type
journal article
Language
en
Open access
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Chemical Physics Letters (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Heart, Lung, and Blood Institute (K02HL080081)
  • National Institute of General Medical Sciences (R01GM064742)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Molecular spectroscopy and chirality
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
Keywords
dipolar coupling, chemical shift correlation, resolution enhancement, 4-pentyl-4'-cyanobiphenyl, liquid crystals, oriented samples, membrane proteins, multidimensional NMR

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved resolution in dipolar NMR spectra using constant time evolution PISEMA experiment. https://app.cochat.ai/papers/10.1016/j.cplett.2010.05.078
The paper
Gopinath, T., & Veglia, G. (2010). Improved resolution in dipolar NMR spectra using constant time evolution PISEMA experiment. Chemical Physics Letters. https://doi.org/10.1016/j.cplett.2010.05.078

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.