Machine learning “red dot”: open-source, cloud, deep convolutional neural networks in chest radiograph binary normality classification
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
AIM To develop a machine learning-based model for the binary classification of chest radiography abnormalities, to serve as a retrospective tool in guiding clinician reporting prioritisation. MATERIALS AND METHODS The open-source machine learning library, Tensorflow, was used to retrain a final layer of the deep convolutional neural network, Inception, to perform binary normality classification on two, anonymised, public image datasets. Re-training was performed on 47,644 images using commodity hardware, with validation testing on 5,505 previously unseen radiographs. Confusion matrix analysis was performed to derive diagnostic utility metrics. RESULTS A final model accuracy of 94.6% (95% confidence interval [CI]: 94.3-94.7%) based on an unseen testing subset (n=5,505) was obtained, yielding a sensitivity of 94.6% (95% CI: 94.4-94.7%) and a specificity of 93.4% (95% CI: 87.2-96.9%) with a positive predictive value (PPV) of 99.8% (95% CI: 99.7-99.9%) and area under the curve (AUC) of 0.98 (95% CI: 0.97-0.99). CONCLUSION This study demonstrates the application of a machine learning-based approach to classify chest radiographs as normal or abnormal. Its application to real-world datasets may be warranted in optimising clinician workload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616
Machine learning for medical imaging
Erickson, B. J., Korfiatis, P., Akkus, Z., & Kline, T. L. (2017) · RadioGraphics · doi:10.1148/rg.2017160130 · Cited by 1,672
Preparing a collection of radiology examinations for distribution and retrieval
Demner-Fushman, D., Kohli, M. D., Rosenman, M. B., Shooshan, S. E., Rodriguez, L., Antani, S., Thoma, G. R., & McDonald, C. J. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv080 · Cited by 1,164
Cited by
A Novel Transfer Learning Based Approach for Pneumonia Detection in Chest X-ray Images
Chouhan, V., Singh, S. K., Khamparia, A., Gupta, D., Tiwari, P., Moreira, C., Damaševičius, R., & de Albuquerque, V. H. C. (2020) · Applied Sciences · doi:10.3390/app10020559 · Cited by 753
COVID-19 open source data sets: a comprehensive survey
Shuja, J., Alanazi, E., Alasmary, W., & Alashaikh, A. (2021) · Applied Intelligence · doi:10.1007/s10489-020-01862-6 · Cited by 274
Seah, J. C. Y., Tang, C. H. M., Buchlak, Q. D., Holt, X. G., Wardman, J. B., Aimoldin, A., Esmaili, N., Ahmad, H., Pham, H., Lambert, J. F., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00106-0 · Cited by 229
Coy, H., Hsieh, K., Wu, W., Nagarajan, M. B., Young, J. R., Douek, M. L., Brown, M. S., Scalzo, F., & Raman, S. S. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-01929-0 · Cited by 110
Frommeyer, T. C., Fursmidt, R. M., Gilbert, M. M., & Bett, E. S. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.831123 · Cited by 25
Metadata
- Authors
- Yates, E. J., Yates, L. C., & Harvey, H.
- Venue
- Clinical Radiology
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 73
- Issue
- 9
- Pages
- 827-831
- ISSN
- 0009-9260 (ISSN-L)
- OpenAlex
- W2806794719
- Cited by
- 62
- References
- 3
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning “red dot”: open-source, cloud, deep convolutional neural networks in chest radiograph binary normality classification. https://app.cochat.ai/papers/10.1016/j.crad.2018.05.015
- The paper
- Yates, E. J., Yates, L. C., & Harvey, H. (2018). Machine learning “red dot”: open-source, cloud, deep convolutional neural networks in chest radiograph binary normality classification. Clinical Radiology. https://doi.org/10.1016/j.crad.2018.05.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.