Development of a strontium optical lattice clock for the SOC mission on the ISS
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the “Space Optical Clocks” (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project No. 263500, during the years 2011–2015 a compact, a modular and robust strontium lattice optical clock demonstrator has been developed. The goal performance is a fractional frequency instability below 1 × 10 − 15 τ − 1 / 2 and a fractional inaccuracy below 5 × 10 − 17 . Here we describe the current status of the apparatus' development, including the laser subsystems. The robust preparation of cold 88 Sr atoms in a second-stage magneto-optical trap (MOT) is achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Self-citationQuantum tests of the Einstein Equivalence Principle with the STE–QUEST space mission
Altschul, B., Bailey, Q. G., Blanchet, L., Bongs, K., Bouyer, P., Cacciapuoti, L., Capozziello, S., Gaaloul, N., Giulini, D., Hartwig, J., et al. (2015) · Advances in Space Research · doi:10.1016/j.asr.2014.07.014 · Cited by 204
Self-citationDelivering pulsed and phase stable light to atoms of an optical clock
Falke, S., Misera, M., Sterr, U., & Lisdat, C. (2012) · Applied Physics B · doi:10.1007/s00340-012-4952-6 · Cited by 57
Self-citation
Research works printed but not linked: 17
- [1] Hess, M.P.; Stringhetti, L.; Hummelsberger, B.; Hausner, K.; Stalford, R.; Nasca, R.; Cacciapuoti, L.; Much, R.; Feltham, S.; Vudali, T.; Leger, B.; Picard, F.; Massonnet, D.; Rochat, P.; Goujon, D.; Schäfer, W.; Laurent, P.; Lemonde, P.; Clairon, A.; Wolf, P.; Salomon, C.; Prochazka, I.; Schreiber, U.; Montenbruck, O. Acta Astronaut., 69 (2011), p. 929 · DOI
- [2] Poli, N.; Oates, C.W.; Gill, P.; Tino, G.M. Riv. Nuovo Cimento, 36 (2013), p. 555
- [3] Poli, N.; Schioppo, M.; Vogt, S.; Falke, S.; Sterr, U.; Lisdat, C.; Tino, G.M. Appl. Phys. B, 117 (2014), p. 1107 · DOI · Paper page
- [4] Schiller, S.; Gorlitz, A.; Nevsky, A.; Alighanbari, S.; Vasilyev, S.; Abou-Jaoudeh, C.; Mura, G.; Franzen, T.; Sterr, U.; Falke, S.; Lisdat, C.; Rasel, E.; Kulosa, A.; Bize, S.; Lodewyck, J.; Tino, G.; Poli, N.; Schioppo, M.; Bongs, K.; Singh, Y.; Gill, P.; Barwood, G.; Ovchinnikov, Y.; Stuhler, J.; Kaenders, W.; Braxmaier, C.; Holzwarth, R.; Donati, A.; Lecomte, S.; Calonico, D.; Levi, F. EFTF 2012 (2012), pp. 412-418
- [5] Hoffmann, B. Phys. Rev., 121 (1961), p. 337 · DOI
- [6] Krisher, T.P. Phys. Rev. D, 53 (1996), p. R1735 · DOI
- [7] Nevsky, A.Y.; Alighanbari, S.; Chen, Q.; Ernsting, I.; Vasilyev, S.; Schiller, S.; Barwood, G.; Gill, P.; Poli, N.; Tino, G.M. Opt. Lett., 38 (2013), p. 4903 · DOI
- [8] Hill, I.R.; Ovchinnikov, Y.B.; Bridge, E.M.; Curtis, E.A.; Gill, P. J. Phys. B, 47 (2014), p. 75006 · DOI
- [9] Schioppo, M.; Poli, N.; Prevedelli, M.; Falke, S.; Lisdat, C.; Sterr, U.; Tino, G.M. Rev. Sci. Instrum., 83 (2012), p. 103101 · DOI · Paper page
- [10] Mukaiyama, T.; Katori, H.; Ido, T.; Li, Y.; Kuwata-Gonokami, M. Phys. Rev. Lett., 90 (2003), p. 113002 · DOI · Paper page
- [11] Le Targat, R. Horloge à réseau optique au Strontium: une 2ème génération d'horloges à atomes froids, École nationale supérieure des télécommunications – ENST (13/07/2007), 2007 (Ph.D. thesis)
- [13] Baillard, X.; Gauguet, A.; Bize, S.; Lemonde, P.; Laurent, P.; Clairon, A.; Rosenbusch, P. Opt. Commun., 266 (2006), p. 609 · DOI · Paper page
- [14] Dick, G.J. Redendo Beach, 1987, U.S. Naval Observatory, Washington, DC (1988), pp. 133-147
- [15] Legero, T.; Kessler, T.; Sterr, U. J. Opt. Soc. Am. B, 27 (2010), p. 914 · DOI · Paper page
- [16] Argence, B.; Prevost, E.; Lévèque, T.; Le Goff, R.; Bize, S.; Lemonde, P.; Santarelli, G. Opt. Express, 20 (2012), p. 25409 · DOI · Paper page
- [17] Thompson, R.; Folkner, W.; de Vine, G.; Klipstein, W.; McKenzie, K.; Spero, R.; Yu, N.; Stephens, M.; Leitch, J.; Pierce, R. et al. IEEE 2011 (2011), pp. 1-3
- [18] Vogt, S.; Lisdat, C.; Legero, T.; Sterr, U.; Ernsting, I.; Nevsky, A.; Schiller, S. Appl. Phys. B, 104 (2011), p. 741 · DOI · Paper page
Cited by
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationAEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space
El-Neaj, Y. A., Alpigiani, C., Amairi-Pyka, S., Araújo, H., Balaž, A., Bassi, A., Bathe-Peters, L., Battelier, B., Belić, A., Bentine, E., et al. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-0080-0 · Cited by 348
Self-citationSpace-borne frequency comb metrology
Lezius, M., Wilken, T., Deutsch, C., Giunta, M., Mandel, O., Thaller, A., Schkolnik, V., Schiemangk, M., Dinkelaker, A., Kohfeldt, A., et al. (2016) · Optica · doi:10.1364/optica.3.001381 · Cited by 272
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Self-citation
Metadata
- Authors
- Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., Vogt, S., Sterr, U., Lisdat, C., Le Targat, R., Lodewyck, J., Holleville, D., Venon, B., Bize, S., Barwood, G. P., Gill, P., Hill, I. R., Ovchinnikov, Y. B., Poli, N., Tino, G. M., Stuhler, J., Kaenders, W., & SOC2 team
- Venue
- Comptes Rendus. Physique
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2015-04-15
- Volume
- 16
- Issue
- 5
- Pages
- 553-564
- ISSN
- 1631-0705 (ISSN-L)
- 1878-1535
- OpenAlex
- W2081895692
- Cited by
- 94
- References
- 5
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- ESA
- DLR
- Seventh Framework Programme (263500)
- European Metrology Research Programme (IND14)
- EURAMET
- European Union
- EPSRC (EP/L001713/1)
- Qtea
- Marie-Curie Action ITN
- DFG (RTG 1729)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a strontium optical lattice clock for the SOC mission on the ISS. https://app.cochat.ai/papers/10.1016/j.crhy.2015.03.009
- The paper
- Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., Vogt, S., Sterr, U., Lisdat, C., Le Targat, R., Lodewyck, J., Holleville, D., Venon, B., Bize, S., Barwood, G. P., . . . SOC2 team. (2015). Development of a strontium optical lattice clock for the SOC mission on the ISS. Comptes Rendus. Physique. https://doi.org/10.1016/j.crhy.2015.03.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.