CoChat

Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty

Open access

The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.

Abstract

The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms7896

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Single clock stability measured with a self-comparison. (a) A typical line scan associated with a 1-s interrogation time (open black circles). To explore the limit of coherence in our clock, we scan the clock transition with a 4-s interrogation time and more atoms (solid green squares). Here the linewidth and contrast are affected by the Fourier width and atomic interactions18. (b) A new stability record (black circles, fit with red solid line) achieved by running with 1 s clock pulses and a 60% clock laser duty cycle for each preparation and measurement sequence. In contrast, the previous best independent clock stability1321 (blue dashed line) is . The error bars represent the 1σ uncertainty in the total deviation estimator, calculated assuming a white noise process, which is valid after the atomic servo attack time of ≈30 s.
Figure 1 Single clock stability measured with a self-comparison. (a) A typical line scan associated with a 1-s interrogation time (open black circles). To explore the limit of coherence in our clock, we scan the clock transition with a 4-s interrogation time and more atoms (solid green squares). Here the linewidth and contrast are affected by the Fourier width and atomic interactions18. (b) A new stability record (black circles, fit with red solid line) achieved by running with 1 s clock pulses and a 60% clock laser duty cycle for each preparation and measurement sequence. In contrast, the previous best independent clock stability1321 (blue dashed line) is . The error bars represent the 1σ uncertainty in the total deviation estimator, calculated assuming a white noise process, which is valid after the atomic servo attack time of ≈30 s.CC BY · PubMed Central
Figure 2 The ac Stark shift from the optical lattice. (a) Lattice ac Stark shift measurements, as a function of the differential trap depth ΔU (in units of lattice photon recoil energy), for the current evaluation (red circles) and our previous evaluation (blue squares). Lines are linear fits to data. The lattice frequency for the new evaluation is 172.4 MHz lower than that of the previous evaluation. We determine the magic wavelength in our experimental configuration so that our trapping potential is independent of the electronic state (1S0 or 3P0) for mF=±9/2. Our current evaluation thus achieves the smallest reported lattice ac Stark shift of (−1.3±1.1) × 10−18. Error bars represent 1σ uncertainties (calculated as described in Methods). (b) The calculated lattice ac Stark shift Δνac at the magic wavelength, plotted for different spin states. The trapping potential is independent of the electronic states when the scalar shift and the tensor shift cancel for mF=±9/2.
Figure 2 The ac Stark shift from the optical lattice. (a) Lattice ac Stark shift measurements, as a function of the differential trap depth ΔU (in units of lattice photon recoil energy), for the current evaluation (red circles) and our previous evaluation (blue squares). Lines are linear fits to data. The lattice frequency for the new evaluation is 172.4 MHz lower than that of the previous evaluation. We determine the magic wavelength in our experimental configuration so that our trapping potential is independent of the electronic state (1S0 or 3P0) for mF=±9/2. Our current evaluation thus achieves the smallest reported lattice ac Stark shift of (−1.3±1.1) × 10−18. Error bars represent 1σ uncertainties (calculated as described in Methods). (b) The calculated lattice ac Stark shift Δνac at the magic wavelength, plotted for different spin states. The trapping potential is independent of the electronic states when the scalar shift and the tensor shift cancel for mF=±9/2.CC BY · PubMed Central
Figure 3 Radiation thermometry in the JILA Sr clock. (a) Mounted radiation thermometers inside the Sr clock chamber, surrounded by a BBR shield enclosure. The vacuum chamber is depicted in violet (false color). Two thin-film PRTs are mounted near the centre of the chamber on glass tubes that are sealed to mini vacuum flanges. One sensor is fixed at 2.5 cm from the chamber centre. The other sensor can be translated to measure at the centre of the vacuum chamber (as shown here) or, during normal clock operation, 2.5 cm from the centre. The BBR shield, depicted as a box around the chamber, is used for thermalization, minimizing temperature gradients and enabling passive temperature stabilization. (b) The sensor calibration at the NIST Sensor Science Division. First, the sensor resistance is calibrated to the ITS-90 temperature scale under a He exchange gas (RHe). To calibrate the sensor resistance in vacuum (Rvacuum), we measure Rvacuum–RHe as a function of the temperature difference between the flange (Tflange) and primary (Tprimary) sensors. The lines are linear fits to the data and their slopes quantify the immersion error coefficients, which are markedly different between the two sensors. However, we find negligible immersion errors in the BBR-shielded clock chamber. (c) A long-term record of the temperature and total BBR shift (upper plot), and the temperature difference (lower plot) measured by the two primary sensors. Although temperature fluctuations are within a few hundred mK, the sensor temperature difference (black line) is well within the combined uncertainty of both sensors (shown as the grey 1σ confidence band), which indicates that no calibration shifts occurred during shipping and installation.
Figure 3 Radiation thermometry in the JILA Sr clock. (a) Mounted radiation thermometers inside the Sr clock chamber, surrounded by a BBR shield enclosure. The vacuum chamber is depicted in violet (false color). Two thin-film PRTs are mounted near the centre of the chamber on glass tubes that are sealed to mini vacuum flanges. One sensor is fixed at 2.5 cm from the chamber centre. The other sensor can be translated to measure at the centre of the vacuum chamber (as shown here) or, during normal clock operation, 2.5 cm from the centre. The BBR shield, depicted as a box around the chamber, is used for thermalization, minimizing temperature gradients and enabling passive temperature stabilization. (b) The sensor calibration at the NIST Sensor Science Division. First, the sensor resistance is calibrated to the ITS-90 temperature scale under a He exchange gas (RHe). To calibrate the sensor resistance in vacuum (Rvacuum), we measure Rvacuum–RHe as a function of the temperature difference between the flange (Tflange) and primary (Tprimary) sensors. The lines are linear fits to the data and their slopes quantify the immersion error coefficients, which are markedly different between the two sensors. However, we find negligible immersion errors in the BBR-shielded clock chamber. (c) A long-term record of the temperature and total BBR shift (upper plot), and the temperature difference (lower plot) measured by the two primary sensors. Although temperature fluctuations are within a few hundred mK, the sensor temperature difference (black line) is well within the combined uncertainty of both sensors (shown as the grey 1σ confidence band), which indicates that no calibration shifts occurred during shipping and installation.CC BY · PubMed Central
Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.
Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.CC BY · PubMed Central
Figure 5 Evaluation of the density shift. The overlapping Allan deviation shows the density shift averaging down for 2,000 atoms and U0=71 Erec. The atom number was modulated between 2,400 and 12,000 atoms. The error bars represent the 1σ uncertainty in the overlapping Allan deviation estimator.
Figure 5 Evaluation of the density shift. The overlapping Allan deviation shows the density shift averaging down for 2,000 atoms and U0=71 Erec. The atom number was modulated between 2,400 and 12,000 atoms. The error bars represent the 1σ uncertainty in the overlapping Allan deviation estimator.CC BY · PubMed Central
Figure 6 The lattice Stark data used in this work. For ΔU=U2–U1, the colour coding represents the values of U2 used for each point. Data that has the same value of ΔU are averaged to produce the points in Fig. 2a. The error bars represent the 1σ uncertainty in each point.
Figure 6 The lattice Stark data used in this work. For ΔU=U2–U1, the colour coding represents the values of U2 used for each point. Data that has the same value of ΔU are averaged to produce the points in Fig. 2a. The error bars represent the 1σ uncertainty in each point.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Research works printed but not linked: 3

  1. Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
  2. Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
  3. Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).

Cited by

See all 780

Metadata

Authors
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
Affiliations
  • National Institute of Standards and Technology (US)
  • Centre for Quantum Technologies (SG)
Corresponding author
Ye, J.
Venue
Nature Communications
Published
2015-04-21
Volume
6
Issue
1
Pages
6896-6896
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2073958075
Cited by
780
References
53
Citations by year
2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
FWCI
51.26
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • arXiv (Cornell University) (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • National University of Singapore (submittedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • arXiv (Cornell University)
Funders
  • National Science Foundation
  • National Institute of Standards and Technology
  • Advanced Research Projects Agency
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
Keywords
optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty. https://app.cochat.ai/papers/10.1038/ncomms7896
The paper
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J. (2015). Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty. Nature Communications. https://doi.org/10.1038/ncomms7896

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.