Cited by 44

The DOI matches its Crossref record.

Low temperature radiative properties of materials used in cryogenics

Musilova, V., Hanzelka, P., Kralik, T., Srnka, A.·2005·Cryogenics

Overview

Integrity signals

Registry

Crossref · 10.1016/j.cryogenics.2004.11.010

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Kralik et al.'s study confirmed the considerable influence of surface treatments on radiative properties.

    “The study confirmed the considerable influence of surface treatments on radiative properties, thereby providing reliable data for the thermal design of cryogenic systems.”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. Domoto, 1969, Prediction of the total emissivity of metals at cryogenic temperatures, Adv Cryog Eng, 14, 230, 10.1007/978-1-4757-0549-2_29 · DOI
  2. Tsujimoto, 1982, Thermal radiative properties of some cryogenic materials, Cryogenics, 22, 591, 10.1016/0011-2275(82)90007-8 · DOI
  3. Benbow, 1975, Optical absorption in Al and dilute alloys of Mg and Li in Al at 4.2K, Phys Rev B, 12, 5615, 10.1103/PhysRevB.12.5615 · DOI
  4. Ramanathan, 1977, Total hemispherical emissivities of copper, aluminium, and silver, Appl Opt, 16, 2810, 10.1364/AO.16.002810 · DOI · Paper page
  5. Giulietti, 1979, A calorimetric technique for measuring total emissivity of solid materials and coatings at low temperatures, J Phys D: Appl Phys, 12, 2027, 10.1088/0022-3727/12/12/006 · DOI
  6. Giulietti, 1981, Emissivity and absorptivity measurements on some high-purity metals at low temperatures, J Phys D Appl Phys, 14, 877, 10.1088/0022-3727/14/5/019 · DOI
  7. Hawks, 1970, Total normal emittances of some real surfaces at cryogenic temperatures, Adv Cryog Eng, 16, 467
  8. Ramanathan, 1952, Infra-red absorption by metals at low temperatures, Proc Phys Soc London A, 65, 532, 10.1088/0370-1298/65/7/308 · DOI
  9. Obert, 1982, Emissivity measurements of metallic surfaces used in cryogenic applications, Adv Cryog Eng, 27, 293
  10. Amano, 1991, An experimental study of thermal radiation at cryogenic temperatures, Heat Transfer-Jap Res, 20, 307
  11. Anderson, 1971, Measurement and control of thermal radiation below 6K, J Low Temp Phys, 5, 591, 10.1007/BF00628187 · DOI · Paper page
  12. Kralik T, Hanzelka P, Musilova V, Srnka A. Device for measurement of thermal emissivity at cryogenic temperatures. In: Proceedings of the 8th Cryogenics 2004, IIR int conf, Prague, April 2004. p. 23–9.
  13. Ruccia, 1967, The surface emittance of vacuum-metalized polyester film, Adv Cryog Eng, 12, 300, 10.1007/978-1-4757-0489-1_31 · DOI

Cited by

Sorted by citations

Metadata

Authors
Musilova, V., Hanzelka, P., Kralik, T., & Srnka, A.
Venue
Cryogenics
Publisher
Elsevier BV
Published
2005-08
Volume
45
Issue
8
Pages
529-536
ISSN
0011-2275
Cited by
44
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review