The DOI matches its Crossref record.
Performance evaluation of electrocoagulation process using iron-rod electrodes for removing hardness from drinking water
Abstract
Hard water causes many problems in domestic and industrial usage. The growing demands for water of high quality necessitate the development of modern and cost-effective technologies for softening hard and very hard waters. One of these techniques is the electrocoagulation process (EC). The purpose of this study was to investigate the efficiency of EC process in removal of water hardness through iron-rod electrodes in different circumstances. This study was conducted as a pilot plant. Experimental water sample was taken from water distribution network of Anar City located in northwestern part of Kerman Province, Iran. The indices for calcium and total hardness removal in pH (3.0, 7.0, and 10.0), electrical potential of 6, 12, and 24 V and reaction times of 10, 20, and 30 min were measured. The maximum efficiency of hardness removal which was obtained in pH 10.0, voltage of 12 and reaction time of 60 min are equal to 98.2% and 97.4% for calcium and total hardness, respectively. Final pH of remained solution has also increased which rises with acidic pH and decreases in alcoholic pH, so the results demonstrate the direct effect of pH, potential difference and reaction time on hardness removal using EC process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
Electrocoagulation process in water treatment: A review of electrocoagulation modeling approaches
Hakizimana, J. N., Gourich, B., Chafi, M., Stiriba, Y., Vial, C., Drogui, P., & Naja, J. (2017) · Desalination · doi:10.1016/j.desal.2016.10.011 · Cited by 908
Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review
Sillanpää, M., Ncibi, M. C., Matilainen, A., & Vepsäläinen, M. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.09.113 · Cited by 768
Emerging usage of electrocoagulation technology for oil removal from wastewater: A review
An, C., Huang, G., Yao, Y., & Zhao, S. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.11.062 · Cited by 461
Zaied, B. K., Rashid, M., Nasrullah, M., Zularisam, A. W., Pant, D., & Singh, L. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138095 · Cited by 328
Metadata
- Authors
- Malakootian, M., Mansoorian, H. J., & Moosazadeh, M.
- Venue
- Desalination
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 255
- Issue
- 1-3
- Pages
- 67-71
- ISSN
- 0011-9164 (ISSN-L)
- OpenAlex
- W2098159707
- Cited by
- 199
- References
- 0
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance evaluation of electrocoagulation process using iron-rod electrodes for removing hardness from drinking water. https://app.cochat.ai/papers/10.1016/j.desal.2010.01.015
- The paper
- Malakootian, M., Mansoorian, H. J., & Moosazadeh, M. (2010). Performance evaluation of electrocoagulation process using iron-rod electrodes for removing hardness from drinking water. Desalination. https://doi.org/10.1016/j.desal.2010.01.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.