The DOI matches its Crossref record.
Determination of limiting current density and current efficiency in electrodialysis units
Open accessAbstract
A crucial parameter for the design and operation of electrodialysis (ED) units is the limiting current density (LCD). This is often identified with the diffusion-limited current density, which corresponds to the complete solute depletion in the layer adjacent to the membrane. Current-voltage curves obtained from measurements with electrodes in contact with the solution (i.e. without membranes) are consistent with this interpretation and exhibit a horizontal plateau identifying LCD. However, real ED systems show more complex behaviours, with a reduced-slope tract instead of a plateau and a third region in which the current increases more markedly (overlimiting current). The phenomena involved in the limiting region are not yet totally characterized and the determination of LCD in ED units is still ambiguous. In the present work, we explore the issues related to the identification of LCD, by measurements on ED units, assessing the influence of operating conditions and validating a simplified process simulator. A new method to determine LCD, based on the current efficiency, is proposed and compared with other methods presented in the literature. A second limiting quantity is also identified, i.e. the critical current density, below which diffusion phenomena prevail on migration and a method for its assessment is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gurreri, L., Tamburini, A., Cipollina, A., & Micale, G. (2020) · Membranes · doi:10.3390/membranes10070146 · Cited by 492
Self-citationElectrodialysis for metal removal and recovery: A review
Arana Juve, J.-M., Christensen, F. M. S., Wang, Y., & Wei, Z. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.134857 · Cited by 338
Brine management in desalination industry: From waste to resources generation
Mavukkandy, M. O., Chabib, C. M., Mustafa, I., Al Ghaferi, A., & AlMarzooqi, F. (2019) · Desalination · doi:10.1016/j.desal.2019.114187 · Cited by 283
Metadata
- Authors
- La Cerva, M., Gurreri, L., Tedesco, M., Cipollina, A., Ciofalo, M., Tamburini, A., & Micale, G.
- Venue
- Desalination
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 445
- Pages
- 138-148
- ISSN
- 0011-9164 (ISSN-L)
- OpenAlex
- W2885238843
- Cited by
- 166
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of limiting current density and current efficiency in electrodialysis units. https://app.cochat.ai/papers/10.1016/j.desal.2018.07.028
- The paper
- La Cerva, M., Gurreri, L., Tedesco, M., Cipollina, A., Ciofalo, M., Tamburini, A., & Micale, G. (2018). Determination of limiting current density and current efficiency in electrodialysis units. Desalination. https://doi.org/10.1016/j.desal.2018.07.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.