Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 492Membrane-based Ion Separation TechniquesMembrane Separation TechnologiesElectrokinetic Soil Remediation Techniques

The DOI matches its Crossref record; 574 of the 574 references it cites were found in a registry or an index.

Electrodialysis Applications in Wastewater Treatment for Environmental Protection and Resources Recovery: A Systematic Review on Progress and Perspectives

Open access

Abstract

This paper presents a comprehensive review of studies on electrodialysis (ED) applications in wastewater treatment, outlining the current status and the future prospect. ED is a membrane process of separation under the action of an electric field, where ions are selectively transported across ion-exchange membranes. ED of both conventional or unconventional fashion has been tested to treat several waste or spent aqueous solutions, including effluents from various industrial processes, municipal wastewater or salt water treatment plants, and animal farms. Properties such as selectivity, high separation efficiency, and chemical-free treatment make ED methods adequate for desalination and other treatments with significant environmental benefits. ED technologies can be used in operations of concentration, dilution, desalination, regeneration, and valorisation to reclaim wastewater and recover water and/or other products, e.g., heavy metal ions, salts, acids/bases, nutrients, and organics, or electrical energy. Intense research activity has been directed towards developing enhanced or novel systems, showing that zero or minimal liquid discharge approaches can be techno-economically affordable and competitive. Despite few real plants having been installed, recent developments are opening new routes for the large-scale use of ED techniques in a plethora of treatment processes for wastewater.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/membranes10070146

Cites

574 of 574 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Scientific documents chronology reported on Scopus with “electrodialysis” and “wastewater” search words (article title, abstract or keywords). Source: www.scopus.com, accessed on 7 May 2020.
Figure 1 Scientific documents chronology reported on Scopus with “electrodialysis” and “wastewater” search words (article title, abstract or keywords). Source: www.scopus.com, accessed on 7 May 2020.CC BY · PubMed Central
Figure 2 Classification of the selected papers, reflected in the review structure (Section 4, Section 5 and Section 6 and their sub-sections).
Figure 2 Classification of the selected papers, reflected in the review structure (Section 4, Section 5 and Section 6 and their sub-sections).CC BY · PubMed Central
Figure 3 Schematics of ED techniques: (a) Conventional electrodialysis (ED); (b) Lab-scale ED stack with sheet-flow design (exploded view of one cell pair with an additional CEM); (c) Three-compartment bipolar membrane electrodialysis (BMED); (d) Selectrodialysis (SED) with MVA (the illustration refers to the fractionation of SO4²⁻ from Cl−); (e) Electrodialysis metathesis (EDM); (f) Electrodeionisation (EDI) with ion-exchange resins filling the diluate; (g) Reverse electrodialysis (RED). Red rectangles indicate the repeating units. Panels (a,b,g) are reproduced (adapted) with permission from [16], published by Elsevier, 2018.
Figure 3 Schematics of ED techniques: (a) Conventional electrodialysis (ED); (b) Lab-scale ED stack with sheet-flow design (exploded view of one cell pair with an additional CEM); (c) Three-compartment bipolar membrane electrodialysis (BMED); (d) Selectrodialysis (SED) with MVA (the illustration refers to the fractionation of SO4²⁻ from Cl−); (e) Electrodialysis metathesis (EDM); (f) Electrodeionisation (EDI) with ion-exchange resins filling the diluate; (g) Reverse electrodialysis (RED). Red rectangles indicate the repeating units. Panels (a,b,g) are reproduced (adapted) with permission from [16], published by Elsevier, 2018.CC BY · PubMed Central
Figure 4 Flow-chart of the ED treatment for Ni electroplating rinse wastewater (the IXR extended the water cycle within the third and fourth tank). Reproduced with permission from [177], published by Elsevier, 2017.
Figure 4 Flow-chart of the ED treatment for Ni electroplating rinse wastewater (the IXR extended the water cycle within the third and fourth tank). Reproduced with permission from [177], published by Elsevier, 2017.CC BY · PubMed Central
Figure 5 Electrolysis-ED integrated system treating CuSO4 solutions. Reproduced with permission from [191], published by Elsevier, 2011.
Figure 5 Electrolysis-ED integrated system treating CuSO4 solutions. Reproduced with permission from [191], published by Elsevier, 2011.CC BY · PubMed Central
Figure 6 Two-stage selective ED with MVAs for recovering water and concentrate solution from Cr(VI) electroplating wastewater. Reproduced (adapted) with permission from [195], published by Elsevier, 2009.
Figure 6 Two-stage selective ED with MVAs for recovering water and concentrate solution from Cr(VI) electroplating wastewater. Reproduced (adapted) with permission from [195], published by Elsevier, 2009.CC BY · PubMed Central
Figure 7 Treatment processes for Cr wastewater: (a) EDI with diluate compartment filled by mixed IXRs for separating Cr(VI), water dissociation is highlighted at the bipolar contacts; (b) BMED for recovering Cr(III) after oxidation to Cr(VI). Panel (a) is reproduced (adapted) with permission from [198], published by Elsevier, 2013. Panel (b) is reproduced (adapted) with permission from [203], published by Elsevier, 2020.
Figure 7 Treatment processes for Cr wastewater: (a) EDI with diluate compartment filled by mixed IXRs for separating Cr(VI), water dissociation is highlighted at the bipolar contacts; (b) BMED for recovering Cr(III) after oxidation to Cr(VI). Panel (a) is reproduced (adapted) with permission from [198], published by Elsevier, 2013. Panel (b) is reproduced (adapted) with permission from [203], published by Elsevier, 2020.CC BY · PubMed Central
Figure 8 Schemes of complexation-enhanced ED: (a) Zn2+ recovery from a model Fe3+-contaminated electroplating bath by Fe-citrate neutral complex retention; (b) selective separation of metal cations (Ag+/Zn2+ or Cu2+/Cd2+). The feed solution contains initially the two metal ions M1^(z1+) and M2^(z2+), and the ligand L^(x−), which forms complexes only with M1^(z1+) (i.e., M1Lⁿ⁻ ) in situ. The A400 AEM allows for the transport of anion complexes of ~400D without fouling. Panel (a) is reproduced (adapted) with permission from [224], published by Elsevier, 2018. Panel (b) is reproduced with permission from [226], published by Elsevier, 2017.
Figure 8 Schemes of complexation-enhanced ED: (a) Zn2+ recovery from a model Fe3+-contaminated electroplating bath by Fe-citrate neutral complex retention; (b) selective separation of metal cations (Ag+/Zn2+ or Cu2+/Cd2+). The feed solution contains initially the two metal ions M1^(z1+) and M2^(z2+), and the ligand L^(x−), which forms complexes only with M1^(z1+) (i.e., M1Lⁿ⁻ ) in situ. The A400 AEM allows for the transport of anion complexes of ~400D without fouling. Panel (a) is reproduced (adapted) with permission from [224], published by Elsevier, 2018. Panel (b) is reproduced with permission from [226], published by Elsevier, 2017.CC BY · PubMed Central
Figure 9 SED configuration for recovering Cu2+ and Zn2+ from acidic metallurgical wastewater containing As(VI). Reproduced (adapted) with permission from [231], published by Elsevier, 2018.
Figure 9 SED configuration for recovering Cu2+ and Zn2+ from acidic metallurgical wastewater containing As(VI). Reproduced (adapted) with permission from [231], published by Elsevier, 2018.CC BY · PubMed Central
Figure 10 EDI configuration with diluate compartment filled by layered bed for the treatment of a Co2+ solution simulating the primary coolant from nuclear power plants: (a) sketch of the bed packing; (b) stack with three repetitive units with four channels each. Reproduced (adapted) with permission from [233], published by Elsevier, 2004.
Figure 10 EDI configuration with diluate compartment filled by layered bed for the treatment of a Co2+ solution simulating the primary coolant from nuclear power plants: (a) sketch of the bed packing; (b) stack with three repetitive units with four channels each. Reproduced (adapted) with permission from [233], published by Elsevier, 2004.CC BY · PubMed Central
Figure 11 Flowsheet of the pickling liquor recovery by BMED-ED coupling. Reproduced (adapted) with permission from [38], published by Elsevier, 1991.
Figure 11 Flowsheet of the pickling liquor recovery by BMED-ED coupling. Reproduced (adapted) with permission from [38], published by Elsevier, 1991.CC BY · PubMed Central
Figure 12 Schematics of ion substitution ED with three-compartment repeating units for the conversion of metal finishing waste acid into organic acid. Reproduced with permission from [255], published by Elsevier, 2019.
Figure 12 Schematics of ion substitution ED with three-compartment repeating units for the conversion of metal finishing waste acid into organic acid. Reproduced with permission from [255], published by Elsevier, 2019.CC BY · PubMed Central
Figure 13 Modified ED equipped with NF membrane in place of CEM. Monovalent cations A+ (e.g., H+) can move across the NF membrane, while divalent cations B2+ (e.g., Zn2+) are retained. Reproduced with permission from [261], published by Elsevier, 2016.
Figure 13 Modified ED equipped with NF membrane in place of CEM. Monovalent cations A+ (e.g., H+) can move across the NF membrane, while divalent cations B2+ (e.g., Zn2+) are retained. Reproduced with permission from [261], published by Elsevier, 2016.CC BY · PubMed Central
Figure 14 Rayon process flowsheet with BMED: (a) Two-compartment configuration (BM-CEM); (b) Three-compartment configuration. Panel (a) is reproduced with permission from [37], published by Elsevier, 1988. Panel (b) is reproduced with permission from [38], published by Elsevier, 1991.
Figure 14 Rayon process flowsheet with BMED: (a) Two-compartment configuration (BM-CEM); (b) Three-compartment configuration. Panel (a) is reproduced with permission from [37], published by Elsevier, 1988. Panel (b) is reproduced with permission from [38], published by Elsevier, 1991.CC BY · PubMed Central
Figure 15 Valorisation of salt mixture wastewater by SED-BMED integration: (a) Scheme of the process; (b) Sketch of SED with MVAs. Reproduced (adapted) with permission from [285], published by Elsevier, 2016.
Figure 15 Valorisation of salt mixture wastewater by SED-BMED integration: (a) Scheme of the process; (b) Sketch of SED with MVAs. Reproduced (adapted) with permission from [285], published by Elsevier, 2016.CC BY · PubMed Central
Figure 16 BMED SoxalTM process for flue gas desulfurisation. Reproduced (adapted) with permission from [38], published by Elsevier, 1991.
Figure 16 BMED SoxalTM process for flue gas desulfurisation. Reproduced (adapted) with permission from [38], published by Elsevier, 1991.CC BY · PubMed Central
Figure 17 ED for heat stable salt removal from monoethanolamine solvent: (a) principle of the process; (b) flow scheme of the two-stage ED, where the concentrate stream after the first stage goes to the second stage to reduce monoethanolamine loss. Reproduced from [295].
Figure 17 ED for heat stable salt removal from monoethanolamine solvent: (a) principle of the process; (b) flow scheme of the two-stage ED, where the concentrate stream after the first stage goes to the second stage to reduce monoethanolamine loss. Reproduced from [295].CC BY · PubMed Central
Figure 18 BMED recovering naphthenic acids from sodium naphtenates: (a) BM-CEM-CEM configuration; (b) flow scheme with electrodialyzer (1), Raschig rings (2), pumps (3) and tanks (4). Reproduced (adapted) with permission from [321], published by Elsevier, 2019.
Figure 18 BMED recovering naphthenic acids from sodium naphtenates: (a) BM-CEM-CEM configuration; (b) flow scheme with electrodialyzer (1), Raschig rings (2), pumps (3) and tanks (4). Reproduced (adapted) with permission from [321], published by Elsevier, 2019.CC BY · PubMed Central
Figure 19 Scheme of ED desalination of polymer flooding produced water. Reproduced from [343], published by Elsevier, 2018.
Figure 19 Scheme of ED desalination of polymer flooding produced water. Reproduced from [343], published by Elsevier, 2018.CC BY · PubMed Central
Figure 20 Scheme of FO–ED integrated process for wastewater (or brackish water) reclamation. Reproduced (adapted) with permission from [420], published by American Chemical Society, 2013.
Figure 20 Scheme of FO–ED integrated process for wastewater (or brackish water) reclamation. Reproduced (adapted) with permission from [420], published by American Chemical Society, 2013.CC BY · PubMed Central
Figure 21 SED stack equipped with MVAs to fractionate and concentrate phosphate. Reproduced (adapted) with permission from [437], published by Elsevier, 2015.
Figure 21 SED stack equipped with MVAs to fractionate and concentrate phosphate. Reproduced (adapted) with permission from [437], published by Elsevier, 2015.CC BY · PubMed Central
Figure 22 Conceptual scheme of the recovery of materials from anaerobic digestion of WWTP excess sludge, including ED concentration of nutrients from centrate after struvite precipitation for fertilizer production. Reproduced (adapted) with permission from [447], published by Elsevier, 2018.
Figure 22 Conceptual scheme of the recovery of materials from anaerobic digestion of WWTP excess sludge, including ED concentration of nutrients from centrate after struvite precipitation for fertilizer production. Reproduced (adapted) with permission from [447], published by Elsevier, 2018.CC BY · PubMed Central
Figure 23 Flowsheet with mass balances of the pilot plant for urine-water solution treatment. Reproduced with permission from [459], published by Elsevier, 2018.
Figure 23 Flowsheet with mass balances of the pilot plant for urine-water solution treatment. Reproduced with permission from [459], published by Elsevier, 2018.CC BY · PubMed Central
Figure 24 Schematics of ED methods for animal farming effluents: (a) four-compartment SED of swine manure digestate; (b) BMED of pig manure hydrolysate. Panel (a) is reproduced (adapted) with permission from [468] published by Elsevier, 2019. Panel (b) is reproduced (adapted) with permission from [469], published by Elsevier, 2018.
Figure 24 Schematics of ED methods for animal farming effluents: (a) four-compartment SED of swine manure digestate; (b) BMED of pig manure hydrolysate. Panel (a) is reproduced (adapted) with permission from [468] published by Elsevier, 2019. Panel (b) is reproduced (adapted) with permission from [469], published by Elsevier, 2018.CC BY · PubMed Central
Figure 25 Scheme continuous ED regeneration integrated into a liquid desiccant dehumidification system. Reproduced (adapted) with permission from [480], published by Elsevier, 2019.
Figure 25 Scheme continuous ED regeneration integrated into a liquid desiccant dehumidification system. Reproduced (adapted) with permission from [480], published by Elsevier, 2019.CC BY · PubMed Central
Figure 26 BWRO-ED desalination process. EDR treats the RO retentate (1). The EDR diluate product (2) can go through the second RO step (3) or, if it is sufficiently desalted, is conveyed with the permeate (4). The EDR concentrate (7) is sent to the seeded crystallizer/settler, and to the submerged UF module, thus the crystal-free concentrated stream (7′) recirculates to the EDR. The bleed stream (6) is evaporated by the WAIV unit. Reproduced with permission from [492], published by Elsevier, 2010.
Figure 26 BWRO-ED desalination process. EDR treats the RO retentate (1). The EDR diluate product (2) can go through the second RO step (3) or, if it is sufficiently desalted, is conveyed with the permeate (4). The EDR concentrate (7) is sent to the seeded crystallizer/settler, and to the submerged UF module, thus the crystal-free concentrated stream (7′) recirculates to the EDR. The bleed stream (6) is evaporated by the WAIV unit. Reproduced with permission from [492], published by Elsevier, 2010.CC BY · PubMed Central
Figure 27 Flowcharts of three-stage ED systems for water reclamation and salt production from SWRO brine: (a) conventional ED; (b) ED with MVMs in the first stage, followed by conventional ED in the second and third stage. Panel (a) is reproduced (adapted) with permission from [495], published by Elsevier, 2014. Panel (b) is reproduced (adapted) with permission from [499], published by Elsevier, 2017.
Figure 27 Flowcharts of three-stage ED systems for water reclamation and salt production from SWRO brine: (a) conventional ED; (b) ED with MVMs in the first stage, followed by conventional ED in the second and third stage. Panel (a) is reproduced (adapted) with permission from [495], published by Elsevier, 2014. Panel (b) is reproduced (adapted) with permission from [499], published by Elsevier, 2017.CC BY · PubMed Central
Figure 28 Conceptual scheme of SWRO-EDM for water and salts recovery. Reproduced with permission from [41], published by Elsevier, 2019.
Figure 28 Conceptual scheme of SWRO-EDM for water and salts recovery. Reproduced with permission from [41], published by Elsevier, 2019.CC BY · PubMed Central
Figure 29 Scheme of the WWTP with RO-ED water recovery. Reproduced with permission from [509], published by Elsevier, 2011.
Figure 29 Scheme of the WWTP with RO-ED water recovery. Reproduced with permission from [509], published by Elsevier, 2011.CC BY · PubMed Central
Figure 30 Scheme of the IX-RO-ED system for concentrating LiCl from industrial lithium-containing wastewater. Reproduced with permission from [520], published by American Chemical Society, 2019.
Figure 30 Scheme of the IX-RO-ED system for concentrating LiCl from industrial lithium-containing wastewater. Reproduced with permission from [520], published by American Chemical Society, 2019.CC BY · PubMed Central
Figure 31 Process scheme of IX water production and two-stage ED treatment of brine. (1) Surface water from IJssel lake (the Netherlands), (2) ceramic MF and advanced oxidation, (3) NaCl regenerating solution, (4) spent regeneration brine, (5) concentrate from monovalent selective ED, (6) diluate from monovalent selective ED, (7) NOM-containing diluate from conventional ED, (8) multivalent salts-containing concentrate from conventional ED. Reproduced (adapted) from [521], published by Elsevier, 2019.
Figure 31 Process scheme of IX water production and two-stage ED treatment of brine. (1) Surface water from IJssel lake (the Netherlands), (2) ceramic MF and advanced oxidation, (3) NaCl regenerating solution, (4) spent regeneration brine, (5) concentrate from monovalent selective ED, (6) diluate from monovalent selective ED, (7) NOM-containing diluate from conventional ED, (8) multivalent salts-containing concentrate from conventional ED. Reproduced (adapted) from [521], published by Elsevier, 2019.CC BY · PubMed Central
Figure 32 Scheme and experimental set-up of BMSED for acid/base recovery from SWRO brine. Reproduced with permission from [531], published by Elsevier, 2018.
Figure 32 Scheme and experimental set-up of BMSED for acid/base recovery from SWRO brine. Reproduced with permission from [531], published by Elsevier, 2018.CC BY · PubMed Central
Figure 33 Desalination systems with RED using desalination brine for recovering energy: (a) RO-RED scheme in which RED receives the SWRO brine and a secondary effluent; (b) RO-MD-RED scheme; (c) RO-MCDI-RED scheme; (d) ED-RED scheme; (e) ED-RED process integrated in single stack (four-channel repetitive unit, coupling an ED cell with an RED cell). Panels (a–e) are reproduced with permission from [424,536,537,538,539] (adapted), respectively, all published by Elsevier, 2013, 2019, 2019, 2017 and 2020, respectively.
Figure 33 Desalination systems with RED using desalination brine for recovering energy: (a) RO-RED scheme in which RED receives the SWRO brine and a secondary effluent; (b) RO-MD-RED scheme; (c) RO-MCDI-RED scheme; (d) ED-RED scheme; (e) ED-RED process integrated in single stack (four-channel repetitive unit, coupling an ED cell with an RED cell). Panels (a–e) are reproduced with permission from [424,536,537,538,539] (adapted), respectively, all published by Elsevier, 2013, 2019, 2019, 2017 and 2020, respectively.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 574 references

Research works printed but not linked: 7

  1. Strathmann, H. (2004). Ion.-Exchange Membrane Separation Processes, Elsevier. [1st ed.].
  2. Tanaka, Y. (2007). Ion. Exchange Membranes: Fundamentals and Applications, Elsevier.
  3. Basile, A., Curcio, E., and Inamuddin, I. (2019). The REAPower Project: Power Production From Saline Waters and Concentrated Brines. Current Trends and Future Developments on (Bio-) Membranes-Membrane Desalination Systems: The Next Generation, Elsevier.
  4. Helfferich, F. (1962). Ion. Exchange, McGraw-Hill.
  5. Kharkats, 1985, Mechanism of “supralimiting” currents at ion-exchange mebrane/electrolyte interfaces, Sov. Electrochem., 21, 917
  6. Basile, A., Curcio, E., and Inamuddin, I. (2019). Membrane Desalination in Shale Gas Industry: Applications and Perspectives. Current Trends and Future Developments on (Bio-) Membranes, Elsevier.
  7. Baker, R.W. (2012). Membrane Technology and Applications, John Wiley & Sons, Ltd.

Cited by

See all 492

Metadata

Authors
Gurreri, L., Tamburini, A., Cipollina, A., & Micale, G.
Affiliations
University of Palermo (IT)
Corresponding author
Tamburini, Alessandro
Venue
Membranes
Publisher
MDPI AG
Published
2020-07-09
Volume
10
Issue
7
Pages
146
ISSN
2077-0375 (ISSN-L)
OpenAlex
W3042024604
Cited by
492
References
574
Citations by year
2026: 62 · 2025: 98 · 2024: 101 · 2023: 82 · 2022: 77 · 2021: 64 · 2020: 8
FWCI
4.83
Type
journal article
Language
en
Open access
Locations
  • Membranes (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Nova Science Publishers (Nova Science Publishers, Inc.) (submittedVersion, other-oa)
Funders
Horizon 2020 (685579, 731187)
Topics
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane-based Ion Separation Techniques
  • Physical Sciences › Environmental Science › Water Science and Technology › Membrane Separation Technologies
  • Physical Sciences › Environmental Science › Environmental Engineering › Electrokinetic Soil Remediation Techniques
Keywords
electrodialysis, wastewater treatment, desalination, ion exchange membranes, resource recovery, heavy metal recovery, nutrient recovery, zero liquid discharge, industrial wastewater, municipal wastewater, energy recovery, membrane separation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrodialysis Applications in Wastewater Treatment for Environmental Protection and Resources Recovery: A Systematic Review on Progress and Perspectives. https://app.cochat.ai/papers/10.3390/membranes10070146
The paper
Gurreri, L., Tamburini, A., Cipollina, A., & Micale, G. (2020). Electrodialysis Applications in Wastewater Treatment for Environmental Protection and Resources Recovery: A Systematic Review on Progress and Perspectives. Membranes. https://doi.org/10.3390/membranes10070146

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.