The application of simple metrics in the assessment of glycaemic variability
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The assessment of glycaemic variability (GV) remains a subject of debate with many indices proposed to represent either short- (acute glucose fluctuations) or long-term GV (variations of HbA1c). For the assessment of short-term within-day GV, the coefficient of variation for glucose (%CV) defined as the standard deviation adjusted on the 24-h mean glucose concentration is easy to perform and with a threshold of 36%, recently adopted by the international consensus on use of continuous glucose monitoring, separating stable from labile glycaemic states. More complex metrics such as the Low Blood Glucose Index (LBGI) or High Blood Glucose Index (HBGI) allow the risk of hypo or hyperglycaemic episodes, respectively to be assessed although in clinical practice its application is limited due to the need for more complex computation. This also applies to other indices of short-term intraday GV including the mean amplitude of glycemic excursions (MAGE), Shlichtkrull's M-value and CONGA. GV is important clinically as exaggerated glucose fluctuations are associated with an enhanced risk of adverse cardiovascular outcomes due primarily to hypoglycaemia. In contrast, there is at present no compelling evidence that elevated short-term GV is an independent risk factor of microvascular complications of diabetes. Concerning long-term GV there are numerous studies supporting its association with an enhanced risk of cardiovascular events. However, this association raises the question as to whether the impact of long-term variability is not simply the consequence of repeated exposure to short-term GV or ambient chronic hyperglycaemia. The renewed emphasis on glucose monitoring with the introduction of continuous glucose monitoring technologies can benefit from the introduction and application of simple metrics for describing GV along with supporting recommendations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Intensive Glucose Lowering in Type 2 Diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802743 · Cited by 7,888
Classification and diagnosis of diabetes mellitus and other categories of glucose intolerance.
National Diabetes Data Group (1979) · Diabetes · doi:10.2337/diab.28.12.1039 · Cited by 4,909
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Ceriello, A., Esposito, K., Piconi, L., Ihnat, M. A., Thorpe, J. E., Testa, R., Boemi, M., & Giugliano, D. (2008) · Diabetes · doi:10.2337/db08-0063 · Cited by 1,310
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Three-year efficacy of complex insulin regimens in type 2 diabetes
Holman, R. R., Farmer, A. J., Davies, M. J., Levy, J. C., Darbyshire, J. L., Keenan, J. F., & Paul, S. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905479 · Cited by 667
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Cited by
Kaze, A. D., Santhanam, P., Erqou, S., Ahima, R. S., & Echouffo-Tcheugui, J. B. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2020-001753 · Cited by 40
Significance of Glycemic Variability in Diabetes Mellitus
Kusunoki, Y., Konishi, K., Tsunoda, T., & Koyama, H. (2022) · Internal Medicine · doi:10.2169/internalmedicine.8424-21 · Cited by 40
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Metadata
- Authors
- Monnier, L., Colette, C., & Owens, D. R.
- Venue
- Diabetes & Metabolism
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 44
- Issue
- 4
- Pages
- 313-319
- ISSN
- 1262-3636 (ISSN-L)
- OpenAlex
- W2794183231
- Cited by
- 106
- References
- 23
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The application of simple metrics in the assessment of glycaemic variability. https://app.cochat.ai/papers/10.1016/j.diabet.2018.02.008
- The paper
- Monnier, L., Colette, C., & Owens, D. R. (2018). The application of simple metrics in the assessment of glycaemic variability. Diabetes & Metabolism. https://doi.org/10.1016/j.diabet.2018.02.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.