Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Open accessThe DOI matches its Crossref record; 129 of the 175 references it cites were found in a registry or an index.
Abstract
Hemoglobin A1c (HbA1c) has long been considered a cornerstone of diabetes mellitus (DM) management, as both an indicator of average glycemia and a predictor of long-term complications among people with DM. However, HbA1c is subject to non-glycemic influences which confound interpretation and as a measure of average glycemia does not provide information regarding glucose trends or about the occurrence of hypoglycemia and/or hyperglycemia episodes. As such, solitary use of HbA1c, without accompanying glucose data, does not confer actionable information that can be harnessed to guide targeted therapy in many patients with DM. While conventional capillary blood glucose monitoring (BGM) sheds light on momentary glucose levels, in practical use the inherent infrequency of measurement precludes elucidation of glycemic trends or reliable detection of hypoglycemia or hyperglycemia episodes. In contrast, continuous glucose monitoring (CGM) data reveal glucose trends and potentially undetected hypo- and hyperglycemia patterns that can occur between discrete BGM measurements. The use of CGM has grown significantly over the past decades as an ever-expanding body of literature demonstrates a multitude of clinical benefits for people with DM. Continually improving CGM accuracy and ease of use have further fueled the widespread adoption of CGM. Furthermore, percent time in range correlates well with HbA1c, is accepted as a validated indicator of glycemia, and is associated with the risk of several DM complications. We explore the benefits and limitations of CGM use, the use of CGM in clinical practice, and the application of CGM to advanced diabetes technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The primary outcome was met and showed benefit in adults of all ages (38,53,54), including seniors (55-57).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
2. Classification and Diagnosis of Diabetes:Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Gaglia, J. L., Hilliard, M. E., Isaacs, D., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s002 · Cited by 2,433
Self-citationAssociation of Health Literacy With Diabetes Outcomes
Schillinger, D. (2002) · JAMA · doi:10.1001/jama.288.4.475 · Cited by 1,938
Nathan, D. M., & for the DCCT/EDIC Research Group (2014) · Diabetes Care · doi:10.2337/dc13-2112 · Cited by 1,832
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Cited by
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 279
Self-citationLu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39
“26 Several studies 27 – 31 have shown a significant correlation between TIR and diabetic microvascular complications, cardiovascular mortality and all-cause mortality.”
BackgroundRosenfeld, R. M., Grega, M. L., Karlsen, M. C., Dabrh, A. M. A., Aurora, R. N., Bonnet, J. P., Donnell, L., Fitzpatrick, S. L., Frates, E. P., Joy, E. A., et al. (2025) · American Journal of Lifestyle Medicine · doi:10.1177/15598276251325488 · Cited by 54
Aktürk, H. K., Battelino, T., Castañeda, J., Arrieta, A., van den Heuvel, T. R. A., & Cohen, O. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0432 · Cited by 27
“18,19 22 Standardized CGM metrics have been established by the International Consensus.”
Metadata
- Authors
- Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D.
- Affiliations
- Northwestern University (US)
- Corresponding author
- Szmuilowicz, Emily D
- Venue
- Endocrine Connections
- Publisher
- Bioscientifica
- Published
- 2023-04-18
- Volume
- 12
- Issue
- 7
- ISSN
- 2049-3614 (ISSN-L)
- PMC
- PMC10305570
- OpenAlex
- W4366239178
- Cited by
- 22
- References
- 175
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 7 · 2023: 1
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Endocrine Connections (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, diabetes management, HbA1c limitations, glycemic variability, hypoglycemia detection, capillary blood glucose monitoring, diabetes complications, diabetes technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes. https://app.cochat.ai/papers/10.1530/ec-23-0085
- The paper
- Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023). Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes. Endocrine Connections. https://doi.org/10.1530/ec-23-0085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

