Cited by 320Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Continuous glucose monitoring: A review of the technology and clinical use

Klonoff, David C., Ahn, David, Drincic, Andjela·2017·Diabetes Research and Clinical Practice

Abstract

Continuous glucose monitoring (CGM) is an increasingly adopted technology for insulin-requiring patients that provides insights into glycemic fluctuations. CGM can assist patients in managing their diabetes with lifestyle and medication adjustments. This article provides an overview of the technical and clinical features of CGM based on a review of articles in PubMed on CGM from 1999 through January 31, 2017. A detailed description is presented of three professional (retrospective), three personal (real-time) continuous glucose monitors, and three sensor integrated pumps (consisting of a sensor and pump that communicate with each other to determine an optimal insulin dose and adjust the delivery of insulin) that are currently available in United States. We have reviewed outpatient CGM outcomes, focusing on hemoglobin A1c (A1C), hypoglycemia, and quality of life. Issues affecting accuracy, detection of glycemic variability, strategies for optimal use, as well as cybersecurity and future directions for sensor design and use are discussed. In conclusion, CGM is an important tool for monitoring diabetes that has been shown to improve outcomes in patients with type 1 diabetes mellitus. Given currently available data and technological developments, we believe that with appropriate patient education, CGM can also be considered for other patient populations.

Integrity signals

Registry

Crossref · 10.1016/j.diabres.2017.08.005

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The development of high-reliability glucose monitoring devices requires new technologies and strategies to make sensors more affordable, non-invasive, and suitable for continuous monitoring.

    “Today, the development of devices for glucose monitoring with high reliability need new technologies and strategies to make those sensors more affordable, non-invasive, and suitable for continuous monitoring of glycemic status 40-42.”
  • CGM sensors measure interstitial glucose concentrations in subcutaneous tissue almost continuously (e.g., every 1-5 min) for several consecutive days or weeks.

    “CGM sensors measure interstitial glucose concentrations in subcutaneous tissue almost continuously (e.g., every 1–5 min) for several consecutive days or weeks [9].”

The citation lists haven’t been fetched yet

References 73 · Cited by 320

Authors
Klonoff, D. C., Ahn, D., & Drincic, A.
Affiliations
  • Mills Peninsula Health Services (US)
  • University of California, Los Angeles (US)
  • University of Nebraska Medical Center (US)
Corresponding author
Klonoff, David C.
Venue
Diabetes Research and Clinical Practice
Publisher
Elsevier BV
Published
2017-11
Volume
133
Pages
178-192
ISSN
0168-8227 (ISSN-L)
OpenAlex
W2752986434
Cited by
320
References
73
Citations by year
2026: 44 · 2025: 42 · 2024: 32 · 2023: 30 · 2022: 34 · 2021: 45 · 2020: 29 · 2019: 43 · 2018: 21
FWCI
3.70
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Research and Clinical Practice (publishedVersion)
  • PubMed (publishedVersion)
Funders
Insulet Corporation
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
continuous glucose monitoring, type 1 diabetes, insulin-treated diabetes, sensor-augmented pump, glycemic variability, HbA1c, hypoglycemia, quality of life, CGM accuracy, cybersecurity, patient education, diabetes management
MeSH terms
Blood Glucose, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Quality of Life, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review