External validation of a commercially available deep learning algorithm for fracture detection in children
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE The purpose of this study was to conduct an external validation of a fracture assessment deep learning algorithm (Rayvolve®) using digital radiographs from a real-life cohort of children presenting routinely to the emergency room. MATERIALS AND METHODS This retrospective study was conducted on 2634 radiography sets (5865 images) from 2549 children (1459 boys, 1090 girls; mean age, 8.5 ± 4.5 [SD] years; age range: 0-17 years) referred by the pediatric emergency room for trauma. For each set was recorded whether one or more fractures were found, the number of fractures, and their location found by the senior radiologists and the algorithm. Using the senior radiologist diagnosis as the standard of reference, the diagnostic performance of deep learning algorithm (Rayvolve®) was calculated via three different approaches: a detection approach (presence/absence of a fracture as a binary variable), an enumeration approach (exact number of fractures detected) and a localization approach (focusing on whether the detected fractures were correctly localized). Subgroup analyses were performed according to the presence of a cast or not, age category (0-4 vs. 5-18 years) and anatomical region. RESULTS Regarding detection approach, the deep learning algorithm yielded 95.7% sensitivity (95% CI: 94.0-96.9), 91.2% specificity (95% CI: 89.8-92.5) and 92.6% accuracy (95% CI: 91.5-93.6). Regarding enumeration and localization approaches, the deep learning algorithm yielded 94.1% sensitivity (95% CI: 92.1-95.6), 88.8% specificity (95% CI: 87.3-90.2) and 90.4% accuracy (95% CI: 89.2-91.5) for both approaches. Regarding age-related subgroup analyses, the deep learning algorithm yielded greater sensitivity and negative predictive value in the 5-18-years age group than in the 0-4-years age group for the detection approach (P < 0.001 and P = 0.002) and for the enumeration and localization approaches (P = 0.012 and P = 0.028). The high negative predictive value was robust, persisting in all of the subgroup analyses, except for patients with casts (P = 0.001 for the detection approach and P < 0.001 for the enumeration and localization approaches). CONCLUSION The Rayvolve® deep learning algorithm is very reliable for detecting fractures in children, especially in those older than 4 years and without cast.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Darzi, A., Holmes, C., Yau, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1037-7 · Cited by 933
Park, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., Ashrafian, H., Beam, A. L., Collins, G. S., Darzi, A., Deeks, J. J., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30219-3 · Cited by 486
Kim, D. W., Jang, H. Y., Kim, K. W., Shin, Y., & Park, S. H. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0025 · Cited by 459
Understanding artificial intelligence based radiology studies: What is overfitting?
Mutasa, S., Sun, S., & Ha, R. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.04.025 · Cited by 216
Cited by
Artificial intelligence in emergency radiology: A review of applications and possibilities
Katzman, B. D., van der Pol, C. B., Soyer, P., & Patlas, M. N. (2023) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.07.005 · Cited by 97
Agrawal, A., Khatri, G. D., Khurana, B., Sodickson, A. D., Liang, Y., & Dreizin, D. (2023) · Emergency Radiology · doi:10.1007/s10140-023-02121-0 · Cited by 41
Miró Catalina, Q., Vidal-Alaball, J., Fuster-Casanovas, A., Escalé-Besa, A., Ruiz Comellas, A., & Solé-Casals, J. (2024) · Scientific Reports · doi:10.1038/s41598-024-55792-1 · Cited by 23
Metadata
- Authors
- Dupuis, M., Delbos, L., Veil, R., & Adamsbaum, C.
- Venue
- Diagnostic and Interventional Imaging
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 103
- Issue
- 3
- Pages
- 151-159
- ISSN
- 2211-5684 (ISSN-L)
- OpenAlex
- W3216436957
- Cited by
- 94
- References
- 5
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.