Long-term operation of carbon dioxide capture system from a real coal-fired flue gas using dry regenerable potassium-based sorbents
Open accessThe DOI matches its Crossref record.
Abstract
Korea Institute of Energy Research (KIER) and Korea Electric Power Research Institute (KEPRI) have been developing a CO2 capture technology using dry sorbents. The CO2 removal in dry sorbent CO2 capture system consists of two reactors for carbonation and regeneration. We used dry sorbent manufactured by spray-drying method contains potassium carbonate, which was supplied by KEPRI in order to investigate the sorbent performance in continuous operation mode with solid circulation between a fast fluidized bed type carbonation reactor (13.5 m tall pipe of 0.075 m i.d.) and a bubbling fluidized bed type regeneration reactor (2 m tall bed of 0.25 m i.d.). We used the real flue gas from 2MW coal-fired circulating fluidized bed combustor to check possibility of deactivation of dry sorbent by contaminants such as SOx and NOx in the real flue gas for the 100 Nm3/hr of flue gas treatment facility. The residence time of the dry sorbents was about 3 seconds and 15 minutes in the carbonation reactor and the regeneration reactor, respectively. The CO2 removal during 2 hrs in the whole experiments and the average CO2 removal was above 70%. From the experiment, it was revealed that the removal of heat of sorption in the carbonation reactor was important to increase CO2 removal. During the experiments continuous and smooth operation were accomplished with solid circulation between two reactors. These results indicate that CO2 capture process using potassium carbonate solid sorbent is applicable for CO2 capture in the coal-fired flue gas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Post-Combustion CO 2 Capture Using Solid Sorbents: A Review
Samanta, A., Zhao, A., Shimizu, G. K. H., Sarkar, P., & Gupta, R. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie200686q · Cited by 1,889
Review on Reactor Configurations for Adsorption-Based CO 2 Capture
Dhoke, C., Zaabout, A., Cloete, S., & Amini, S. (2021) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c04547 · Cited by 240
CO2 mineral sequestration: developments toward large‐scale application
Zevenhoven, R., Fagerlund, J., & Songok, J. K. (2011) · Greenhouse Gases: Science and Technology · doi:10.1002/ghg3.7 · Cited by 143
Metadata
- Authors
- Park, Y. C., Jo, S.-H., Ryu, C. K., & Yi, C.-K.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 1
- Issue
- 1
- Pages
- 1235-1239
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W1990261528
- Cited by
- 60
- References
- 0
- FWCI
- 14.39
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term operation of carbon dioxide capture system from a real coal-fired flue gas using dry regenerable potassium-based sorbents. https://app.cochat.ai/papers/10.1016/j.egypro.2009.01.162
- The paper
- Park, Y. C., Jo, S.-H., Ryu, C. K., & Yi, C.-K. (2009). Long-term operation of carbon dioxide capture system from a real coal-fired flue gas using dry regenerable potassium-based sorbents. Energy Procedia. https://doi.org/10.1016/j.egypro.2009.01.162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.