CoChat

A continuous process for manufacture of magnesite and silica from olivine, CO2 and H2O

Open access
Munz, Ingrid Anne, Kihle, Jand, Brandvoll, Øyvind, Machenbach, Ingo, Carey, James William, Haug, Tove Anette, Johansen, Harald, Eldrup, Nils · 2009 · Energy Procedia
Cited by 36

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Mineral carbonation is based on the reaction of CO2 with metal oxide bearing materials to form solid carbonates. Further technology development and cost reduction are however needed for an industrial realisation of mineral carbonation. Added value products are clearly one factor, which may change the cost estimates. Separation of reaction products and sufficient product quality must be demonstrated. A concept of using CO2 and water for reaction with olivine in a continuous process with separation of reaction products has been investigated. The reaction products, magnesite and silica, are of potential commercial interest. The process consists of three steps: (1) dissolution of olivine; (2) precipitation of magnesite and (3) precipitation of silica. Separation and precipitation of the reaction products do not require chemical additives, such as acids or bases, and there will thus be few requirements of chemical reclamation. A semi-continuous set of laboratory-scale experiments including process steps 1 and 2 have been carried out. Experimental conditions were in the range 100–150 bar and 130–250 ∘C. Process step 3 has been tested separately, using process water from step 2. The results show a congruent dissolution of olivine with reaction rates comparable to known kinetic models in the lower end of the temperature range. Precipitation of magnesite and silica has different dependence on pH and temperature, and detailed reaction mechanisms are addressed through the experiments. Magnesite precipitation takes place at high temperature (180–250 ∘C). A magnesite with very low iron-content can be precipitated as the only product in the second reaction step.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.egypro.2009.02.319

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 36

Metadata

Authors
Munz, I. A., Kihle, J., Brandvoll, Ø., Machenbach, I., Carey, J. W., Haug, T. A., Johansen, H., & Eldrup, N.
Venue
Energy Procedia
Publisher
Elsevier BV
Published
2009-02
Volume
1
Issue
1
Pages
4891-4898
ISSN
1876-6102 (ISSN-L)
OpenAlex
W2087761380
Cited by
36
References
5
FWCI
7.41
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A continuous process for manufacture of magnesite and silica from olivine, CO2 and H2O. https://app.cochat.ai/papers/10.1016/j.egypro.2009.02.319
The paper
Munz, I. A., Kihle, J., Brandvoll, Ø., Machenbach, I., Carey, J. W., Haug, T. A., Johansen, H., & Eldrup, N. (2009). A continuous process for manufacture of magnesite and silica from olivine, CO2 and H2O. Energy Procedia. https://doi.org/10.1016/j.egypro.2009.02.319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.