CoChat

Systems analysis and cost estimates for large scale capture of carbon dioxide from air

Open access
Simon, A.J., Kaahaaina, Naluahi B., Julio Friedmann, S., Aines, Roger D. · 2011 · Energy Procedia
Cited by 44

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This paper explores the resource intensity and major cost elements of direct air capture of carbon dioxide. The levelized cost of carbon removal is calculated as the sum of costs resulting from interdependent capture devices, energy supplies, water supplies and sequestration resources. The analysis considers “generic” air capture technology characterized only by its energy use, capture footprint, and water use. Capital costs dominate the analysis, followed by energy efficiency. Four dedicated energy resources are considered: Wind, enhanced geothermal, natural gas combined cycle (NGCC), and NGCC with 90% carbon capture. Nearly carbon-free energy is critical to keeping overall cost of carbon mitigation low. The analysis shows that high second law capture efficiencies (on the order of 10%) and relatively inexpensive capture devices (on the order $0.5 M for an individual device capturing one tonne CO 2 /day) must be achieved if the cost of air capture is to approach $300/tonne- CO 2 . Reaching those goals is likely to require substantial research into the kinetics and thermodynamics of capture chemistry which, respectively, keep the capital and energy costs as low as possible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.egypro.2011.02.196

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Simon, A. J., Kaahaaina, N. B., Julio Friedmann, S., & Aines, R. D.
Venue
Energy Procedia
Publisher
Elsevier BV
Published
2011
Volume
4
Pages
2893-2900
ISSN
1876-6102 (ISSN-L)
OpenAlex
W2085650188
Cited by
44
References
1
FWCI
4.41
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.