Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 357

The DOI matches its Crossref record.

The Performance of a High Solar Fraction Seasonal Storage District Heating System – Five Years of Operation

Open access
Sibbitt, Bruce, McClenahan, Doug, Djebbar, Reda, Thornton, Jeff, Wong, Bill, Carriere, Jarrett, Kokko, John · 2012 · Energy Procedia

Abstract

The Drake Landing Solar Community in Okotoks, Alberta, Canada utilizes a solar thermal system with borehole seasonal storage to supply space heating to 52 detached energy-efficient homes through a district heating network. Systems of similar size and configuration have been constructed in Europe, however, this is the first system of this type designed to supply more than 90% of the space heating with solar energy and the first operating in such a cold climate (5200 degree C-days). Solar heat captured in 2293 m 2 of flat-plate collectors, mounted on the roofs of detached garages, is stored in soil underground and later when needed for space heating, is extracted and distributed through a district system to each home in the subdivision. Independent solar domestic hot water systems installed on every house are designed to supply more than 50% of the water heating load. Annual greenhouse gas emission reductions from energy efficiency improvements and solar energy supply exceed 5 tonnes per house. The seasonal storage utilizes approximately 34,000 m 3 of earth and a grid of 144 boreholes with single u-tube heat exchangers. The system is configured to maintain the centre of the field at the highest temperature to maximize heating capacity and the outer edges at the lowest temperature to minimize losses. A short -term thermal storage consisting of 240 m 3 of water is used to interconnect the collection, distribution and seasonal heat storage subsystems. The system has undergone detailed monitoring since it was brought into service in July 2007 to characterize its performance and to improve the TRNSYS model employed in its design. A solar fraction of 97% in its fifth year of operation, convincingly confirms the design target, a solar fraction of more than 90% in year five, has been met. This paper describes the system and its operation, presents 5 years of measured performance and compares those results against the TRNSYS predicted performance for the same period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.egypro.2012.11.097

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sibbitt, B., McClenahan, D., Djebbar, R., Thornton, J., Wong, B., Carriere, J., & Kokko, J.
Venue
Energy Procedia
Publisher
Elsevier BV
Published
2012
Volume
30
Pages
856-865
ISSN
1876-6102 (ISSN-L)
OpenAlex
W2113408001
Cited by
357
References
0
FWCI
17.57
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.