The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Removal of Carbon Dioxide from Indoor Air Using a Cross-Flow Rotating Packed Bed
Open accessAbstract
This investigation elucidated the performance of the cross-flow rotating packed bed (RPB) in removing carbon dioxide (CO 2 ) from indoor air by chemical absorption. MEA, NaOH, K 2 CO 3 aqueous solutions were used as the model absorbents. The results of this investigation demonstrated that the removal efficiency of CO 2 increased with rotational speed and liquid flow rate, but decreased with gas flow rate. Furthermore, the removal efficiency of CO 2 could be enhanced when H 2 O 2 with an appropriate concentration was added to the K 2 CO 3 aqueous solution. The removal efficiency of CO 2 was found with the order: 1.0 mol/L MEA = 1.0 mol/L NaOH > 5 wt% K 2 CO 3 /0.20 mol/L H 2 O 2 > 5 wt% K 2 CO 3 /0.1 mol/L H 2 O 2 > 5 wt% K 2 CO 3 /0.05 mol/L H 2 O 2 > 5wt% K 2 CO 3 .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Non-ventilation decarbonizing technologies are not always more effective than mechanical air filtering, since their efficiency depends on CO2 concentration, size and type of ionizer, and ventilation rate of the area being treated.
“Nevertheless, it is not always more effective than mechanical air filtering, since its efficiency depends on the CO2 concentration, size, and type of ionizer, and the ventilation rate of the area being treated.”
Citations
Cites
Synthesis of Nanoparticles with Novel Technology: High-Gravity Reactive Precipitation
Chen, J., Wang, Y., Guo, F., Wang, X.-M., & Zheng, C. (2000) · Industrial & Engineering Chemistry Research · doi:10.1021/ie990549a · Cited by 458
Jassim, M. S., Rochelle, G. T., Eimer, D. A., & Ramshaw, C. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie051104r · Cited by 278
Removal of Carbon Dioxide by Absorption in a Rotating Packed Bed
Lin, C., Liu, W., & Tan, C. (2003) · Industrial & Engineering Chemistry Research · doi:10.1021/ie020669+ · Cited by 238
Self-citationAbsorption of carbon dioxide with piperazine and its mixtures in a rotating packed bed
Tan, C., & Chen, J.-E. (2005) · Separation and Purification Technology · doi:10.1016/j.seppur.2005.10.001 · Cited by 200
HIGEE Distillation-An Example of Process Intensification
Ramshaw, C. (1983) · Medical Entomology and Zoology · Cited by 165
Aroonwilas, A., Veawab, A., & Tontiwachwuthikul, P. P. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie980728c · Cited by 158
Characteristics of a Rotating Packed Bed
Liu, H.-S., Lin, C., Wu, S.-C., & Hsu, H. (1996) · Industrial & Engineering Chemistry Research · doi:10.1021/ie960183r · Cited by 153
Self-citationReduction of CO2 concentration in a zinc/air battery by absorption in a rotating packed bed
Cheng, H.-H., & Tan, C. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.07.046 · Cited by 116
Distillation in a Rotating Packed Bed.
Lin, C., Ho, T.-J., & Liu, W. (2002) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.35.1298 · Cited by 111
Self-citationOzone oxidation in a rotating packed bed
Lin, C., & Liu, W. (2003) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.708 · Cited by 90
Self-citationFeasibility of a cross-flow rotating packed bed in removing carbon dioxide from gaseous streams
Lin, C., Chen, B.-C., Chen, Y., et al. (2008) · Separation and Purification Technology · doi:10.1016/j.seppur.2008.02.019 · Cited by 64
Self-citationCharacteristics of cross-flow rotating packed beds
Lin, C., & Chen, B.-C. (2008) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2008.01.004 · Cited by 59
Self-citationEvaluation of alkanolamine solutions for carbon dioxide removal in cross-flow rotating packed beds
Lin, C., Lin, Y., & Tan, C. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.10.009 · Cited by 52
Self-citationCarbon Dioxide Absorption into NaOH Solution in a Cross-flow Rotating Packed Bed
Lin, C. C., & Chen, B. C. (2007) · Journal of Industrial and Engineering Chemistry · Cited by 47
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Ramshaw, C., Mallinson, R.H. 1981, U.S. Patent 4,283,255. · DOI
Cited by
Sorted by citations
Han, M., Park, J., Kim, I., & Yi, H. (2023) · Applied Sciences · doi:10.3390/app132412991 · Cited by 11
Metadata
- Authors
- Lin, C.-C., & Lin, H.-T.
- Affiliations
- Chang Gung University (TW)
- Corresponding author
- Lin, Chia-Chang
- ORCID
- Lin, Chia-Chang
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 37
- Pages
- 1187-1193
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2018572612
- Cited by
- 9
- References
- 14
- Citations by year
- 2024: 1 · 2023: 2 · 2021: 3 · 2020: 1 · 2019: 1 · 2017: 1
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Energy Procedia (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Chemical Engineering › Filtration and Separation › Carbon Dioxide Capture Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Environmental Science › Environmental Engineering › Industrial Gas Emission Control
- Keywords
- carbon dioxide removal, indoor air, chemical absorption, monoethanolamine, sodium hydroxide, potassium carbonate, hydrogen peroxide, rotational speed, liquid flow rate, gas flow rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review