The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Sizing of Residential PV Battery Systems
Open accessAbstract
This paper analyses residential PV battery systems in order to gain insights into their sizing. For this purpose a simulation model was developed and system simulations on a timescale of one minute were performed. Furthermore, a sensitivity analysis was conducted varying the PV system and battery size to identify appropriate system configurations. Based on the simulation results, an economic assessment of PV battery systems was carried out and the cost-optimal configurations for various cost scenarios were determined. The results show that in the considered long-term scenario the conjunction of PV systems with batteries will be not only profitable but also the most economical solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of models to predict insolation on tilted surfaces
Klucher, T. M. (1979) · Solar Energy · doi:10.1016/0038-092x(79)90110-5 · Cited by 710
PV self-consumption optimization with storage and Active DSM for the residential sector
Castillo-Cagigal, M., Caamaño-Martín, E., Matallanas, E., Masa-Bote, D., Gutiérrez, A., Monasterio-Huelin, F., & Jiménez-Leube, J. (2011) · Solar Energy · doi:10.1016/j.solener.2011.06.028 · Cited by 308
Regional PV power prediction for improved grid integration
Lorenz, E., Scheidsteger, T., Hurka, J., Heinemann, D., & Kurz, C. (2011) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.1033 · Cited by 292
Braun, M., Büdenbender, K., Magnor, D., & Jossen, A. (2009) · EU PVSEC · doi:10.4229/24theupvsec2009-4bo.11.2 · Cited by 95
Cited by
Hesse, H., Schimpe, M., Kucevic, D., & Jossen, A. (2017) · Energies · doi:10.3390/en10122107 · Cited by 770
Peer-to-peer energy sharing through a two-stage aggregated battery control in a community Microgrid
Long, C., Wu, J., Zhou, Y., & Jenkins, N. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.097 · Cited by 517
Vartiainen, E., Masson, G., Breyer, C., Moser, D., & Román Medina, E. (2020) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.3189 · Cited by 490
Bobba, S., Mathieux, F., Ardente, F., Blengini, G. A., Cusenza, M. A., Podias, A., & Pfrang, A. (2018) · Journal of Energy Storage · doi:10.1016/j.est.2018.07.008 · Cited by 229
Antić, T., Capuder, T., & Bolfek, M. (2020) · Energies · doi:10.3390/en14010117 · Cited by 51
“It is expected that with the minorizing feed-in payments in the future, an optimal PV battery system size is going to shrink to a small-scale PV battery system [42].”
Background
Metadata
- Authors
- Weniger, J., Tjaden, T., & Quaschning, V.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 46
- Pages
- 78-87
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W1989513893
- Cited by
- 419
- References
- 4
- FWCI
- 40.63
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sizing of Residential PV Battery Systems. https://app.cochat.ai/papers/10.1016/j.egypro.2014.01.160
- The paper
- Weniger, J., Tjaden, T., & Quaschning, V. (2014). Sizing of Residential PV Battery Systems. Energy Procedia. https://doi.org/10.1016/j.egypro.2014.01.160
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.