Design and Experimental Testing of a 1.9MWth Calcium Looping Pilot Plant
Open accessThe DOI matches its Crossref record.
Abstract
Calcium looping (CaL) CO 2 capture process using calcium oxide as a regenerable solid sorbent has been under development at the Industrial Technology Research Institute (ITRI) of Taiwan for several years. At 2013, the 1.9MW th pilot plant has been fully constructed, and the trial runs have been progressed for almost one year. The CO 2 was captured by CaO from the flue gas of the cement plant in a bubbling fluidized-bed carbonator while diesel oil oxy-combustion in the rotary kiln provides the heat required to regenerate the sorbent. The start-up progress of carbonator does not use pre-heating system, but take advantage of heat dissipated by the hot sorbent form the calciner. The flow rate of the flue gas from the stack of the cement plant was 3400 Nm 3 /h with the CO 2 concentration higher than 15 vol%. The test results showed the CO 2 capture efficiency higher than 85% for 7 hours and the CO 2 concentration of the outlet gas was under 2%. The accumulated time of unit operation test in this pilot plant is more than 600 hours, and that for the fully-continuous looping test is more than 300 hours, respectively. The CO 2 capture rate higher than 1 t/h was obtained, which reached the design point of this pilot plant. It is considered as an important milestone for the future construction of a 30 MWth demonstration plant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
Chemical looping beyond combustion – a perspective
Zhu, X., Imtiaz, Q., Donat, F., Müller, C. R., & Li, F. (2020) · Energy & Environmental Science · doi:10.1039/c9ee03793d · Cited by 538
Dunstan, M. T., Donat, F., Bork, A. H., Grey, C. P., & Müller, C. R. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00100 · Cited by 481
Abanades, J. C., Arias, B., Lyngfelt, A., Mattisson, T., Wiley, D. E., Li, H., Ho, M. T., Mangano, E., & Brandani, S. (2015) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2015.04.018 · Cited by 441
A critical review of high-temperature reversible thermochemical energy storage systems
Sunku Prasad, J., Muthukumar, P., Desai, F., Basu, D. N., & Rahman, M. M. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113733 · Cited by 405
Metadata
- Authors
- Chang, M.-H., Chen, W.-C., Huang, C.-M., Liu, W.-H., Chou, Y.-C., Chang, W.-C., Chen, W., Cheng, J.-Y., Huang, K.-E., & Hsu, H.-W.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 63
- Pages
- 2100-2108
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2070858207
- Cited by
- 126
- References
- 0
- FWCI
- 12.85
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Experimental Testing of a 1.9MWth Calcium Looping Pilot Plant. https://app.cochat.ai/papers/10.1016/j.egypro.2014.11.226
- The paper
- Chang, M.-H., Chen, W.-C., Huang, C.-M., Liu, W.-H., Chou, Y.-C., Chang, W.-C., Chen, W., Cheng, J.-Y., Huang, K.-E., & Hsu, H.-W. (2014). Design and Experimental Testing of a 1.9MWth Calcium Looping Pilot Plant. Energy Procedia. https://doi.org/10.1016/j.egypro.2014.11.226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.