Preparation of microencapsulated phase change materials (MEPCM) for thermal energy storage
Open accessThe DOI matches its Crossref record.
Abstract
Microencapsulated phase change materials (MEPCM) could be used for energy saving applications in buildings due to their relatively high energy storage capacities at constant temperature, which could passively reduce peak cooling loads in summer. In this study, poly(methyl methacrylate-co-methacrylic acid) (PMMA-MAA) was used as a shell material to fabricate MEPCM by crosslinking methyl methacrylate (MMA) and methacrylic acid (MAA) through in-situ suspension-like polymerization method. The effects of initiator weight percentage and the ratio of shell monomers for the preparation of MEPCM were also investigated. The experimental results showed that the best MEPCM sample was achieved with a shell monomer weight ratio of 80% MMA : 20% MAA and thermal initiator of 1 wt%. Differential scanning calorimetric (DSC) analysis also showed a latent heat value for the best sample as 170 kJ/kg with a melting temperature of 23.68°C which makes these materials suitable for application in residential buildings. Meanwhile, the core material contents and encapsulation efficiencies were calculated according to the measured results of the DSC. Finally the thermogravimetric (TG) analysis on the samples showed very good thermal stability behaviours ranging between 162.3°C and 204.4°C and therefore satisfies the environmental requirements for most applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Umair, M. M., Zhang, Y., Iqbal, K., Zhang, S., & Tang, B. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.11.017 · Cited by 852
Phase change material thermal energy storage systems for cooling applications in buildings: A review
Faraj, K., Khaled, M., Faraj, J., Hachem, F., & Castelain, C. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109579 · Cited by 519
Micro/nano-encapsulated phase change materials (PCMs) as emerging materials for the food industry
Alehosseini, E., & Jafari, S. M. (2019) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2019.07.003 · Cited by 242
Fabrication and application of complex microcapsules: a review
Bah, M. G., Bilal, H. M., & Wang, J. (2020) · Soft Matter · doi:10.1039/c9sm01634a · Cited by 212
Functionally graded optimisation of adsorption systems with phase change materials
Prado, D. S., Amigo, R. C. R., Hewson, R. W., & Silva, E. C. N. (2021) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-021-02918-y · Cited by 7
“This type of continuous mixture of PCM and adsorbent is possible as both may be particulate (Hawlader et al. 2003; Su et al. 2017).”
Background
Metadata
- Authors
- Su, W., Darkwa, J., Kokogiannakis, G., Zhou, T., & Li, Y.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2017-09
- Volume
- 121
- Pages
- 95-101
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2754604116
- Cited by
- 44
- References
- 0
- FWCI
- 12.88
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.