The Effect of Complex Load on the Reliable Operation of Solar Photovoltaic and Wind Power Stations Integrated into Energy Systems and into Off-Grid Energy Areas
Open accessAbstract
A mass renewable power stations commissioning, first of all solar photovoltaic stations (SPVS) and wind power stations (WPS) shall be associated with the properly implemented complex load modeling while calculating their electric operation modes. This article deals with the basic failures of standard algorithm of SPVS and WPS invertors/converters, Fault Ride Through (FRT), that has to reduce the active power output and to increase that of reactive power, in case of voltage drop. In order to prevent outages of SPVS and WPS equipment during emergency disturbances, the trip set points of SPVS and WPS inventors/converters shall be adjusted to those of the adjacent power network protective relay. In this article, an approach to selecting methods for complex loads modeling, in industrial energy areas, has been developed. A method for calculating the value of critical voltage across the load bars has been considered, and the relevancy to apply the dynamic scale model of electric motor has been substantiated. The specific aspects of the voltage-dependent and frequency-dependent load static characteristics employment, in calculations of electromechanical transient processes, have been analyzed. Recommendations on representing electric motors integrated into complex load circuits, in various software packages designed for operation modes calculations, have been stipulated. Various methods making it possible to take account of electromagnetic transient processes, in rotors of asynchrono…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The duration of voltage dips caused by three-phase short circuits can be 2 times longer than the longest short circuit due to automatic starting of electric motors.
“As shown in [36], the duration of voltage dips caused by three-phase short circuits can be 2 times longer than the longest short circuit due to automatic starting of electric motors.”
From Determining Volt/Var Characteristics of Electric Vehicle Charging Station Inverters for Voltage Regulation in Distribution Networks (2024) · cites this paper as [36]
Cited by
Sorted by citations
Voronin, V., Nepsha, F., & Ilyushin, P. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15120553 · Cited by 3 · see citing works
“As shown in [36], the duration of voltage dips caused by three-phase short circuits can be 2 times longer than the longest short circuit due to automatic starting of electric motors.”
Self-citation
- Authors
- Ilyushin, P. V., Shepovalova, O. V., Filippov, S. P., & Nekrasov, A. A.
- Affiliations
- Russian Academy of Sciences (RU)
- Federal Scientific Agroengineering Center VIM (RU)
- Corresponding author
- Shepovalova, Olga V.
- Venue
- Energy Reports
- Publisher
- Elsevier BV
- Published
- 2022-11
- Volume
- 8
- Pages
- 1515-1529
- ISSN
- 2352-4847 (ISSN-L)
- OpenAlex
- W4296564642
- Cited by
- 30
- References
- 0
- Citations by year
- 2026: 1 · 2025: 14 · 2024: 8 · 2023: 7
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energy Reports (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Russian Science Foundation (21-79-30013)
- Russian Academy of Sciences
- Topics
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- wind farms, fault ride-through, protective relays, voltage drop, electromechanical transients, power supply reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review