Cited by 83Cardiac electrophysiology and arrhythmiasCardiac Arrhythmias and TreatmentsCardiac pacing and defibrillation studies

Classification and mechanism of initiation in patients with congenital long QT syndrome

NODA, T, SHIMIZU, W, SATOMI, K, SUYAMA, K, KURITA, T, AIHARA, N, KAMAKURA, S·2004·European Heart Journal

Abstract

AIMS: To examine the initiating mode of Torsade de Pointes (TdP) in patients with congenital long QT syndrome (LQTS). METHODS AND RESULTS: We evaluated 111 episodes of TdP recorded on the electrocardiograms of 24 patients with congenital LQTS, and clarified the initiating mode, the three consecutive preceding RR intervals defined as C(2), C(1), and C(0), the timing of initiating premature ventricular contraction (PVC) and the cycle length (CL) of TdP. Three different initiating patterns were observed: (1) a "short-long-short" sequence (SLS) pattern (23 patients, 72 TdP, 65%) defined as one or more short-long cardiac cycles followed by an initiating short-coupled PVC (C(1)>C(2) and C(0)), (2) an "increased sinus rate" (ISR) pattern (8 patients, 28 TdP, 25%) defined as a gradual increase in sinus rate with or without T-wave alternans (C(2)>/=C(1)>/=C(0)), and (3) a "changed depolarization" (CD) pattern (5 patients, 11 TdP, 10%) defined as a sudden long-coupled PVC or fusion beat followed by short-coupled PVC. The C(0) was shorter in ISR than SLS and CD (mean C(0): 488 vs. 587 and 603 ms, respectively; P<0.05). Therefore, the initiating PVC appeared near the T-wave peak of the last beat before onset in ISR, while it occurred after the T-wave peak in SLS and CD. The CL of TdP was shorter in ISR than in SLS (256 vs. 295 ms, P<0.05). CONCLUSIONS: Our data show the existence of three predominant initiating modes of TdP in patients with congenital LQTS and suggests a differential mechanism of initiation of TdP for each mode.

Integrity signals

Registry

Crossref · 10.1016/j.ehj.2004.08.020

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Significant QTc prolongation (to intervals above 470-500 ms) is known to result in a risk of potentially fatal arrhythmias, such as Torsade de Pointes.

    “Similarly, significant QTc prolongation (to intervals above 470–500 ms) is known to result in a risk of potentially fatal arrhythmias, such as Torsade de Pointes [100].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
NODA, T., SHIMIZU, W., SATOMI, K., SUYAMA, K., KURITA, T., AIHARA, N., & KAMAKURA, S.
Corresponding author
NODA, T
Venue
European Heart Journal
Published
2004-12
Volume
25
Issue
23
Pages
2149-2154
ISSN
0195-668X (ISSN-L)
OpenAlex
W2175776907
Cited by
83
References
29
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 7 · 2020: 1 · 2019: 7 · 2017: 3 · 2016: 2 · 2015: 5 · 2014: 3 · 2013: 4 · 2012: 2
FWCI
3.92
Type
journal article
Language
en
Open access
closed
Locations
  • European Heart Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
congenital long QT syndrome, torsades de pointes, premature ventricular contractions, T-wave alternans, cycle length
MeSH terms
Adolescent, Adult, Child, Child, Preschool, Electrocardiography, Female, Humans, Infant, Long QT Syndrome, Male, Middle Aged, Torsades de Pointes, Ventricular Premature Complexes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review