The DOI matches its Crossref record.
Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve?☆
Open accessAbstract
OBJECTIVE: There is lack of information regarding the long-term behavior of aortic valve reconstruction with pericardium (AoR). A 16-year follow-up is reported here. METHODS: Between 1988 and 1995, 92 consecutive patients had AoR with bovine (Group I, n=27) or glutaraldehyde-treated autologous pericardium (Group II, n=65). The mean age was 30 years (range 12-68). There were 65% males, 92% in sinus rhythm, 84% had rheumatic etiology and 36% had 'other valve' surgery. Mitral valve replacement with a mechanical prosthesis is a contraindication to the operation. RESULTS: Hospital mortality was 2%. The reconstructed aortic valve performed well with excellent hemodynamics. The mean follow-up interval was 10.5+/-4 years, range 9-16 years (longer for group I,12 versus 10 years) with 4% late deaths and seven patients lost to follow-up. Survival rate was 85+/-4%. There were no episodes of thromboembolism. Freedom from reoperation for the whole group was 68+/-5% at 10 years and 47+/-6% at 16 years. For group I, it was 68+/-9% at 10 years and 48+/-10% at 16 years, while for group II it was 72+/-6 and 45+/-8% at 10 and 15 years, respectively. Excluding endocarditis (one in group I and seven in group II) and 'other' reasons for reoperation (two in group I and three in group II), the freedom from structural valve degeneration (SVD) at 10 and 16 years was 78+/-1 and 55+/-10% for group I. For group II, it was 80+/-5% at 10 years and 58+/-9% at 15 years. The mean interval at which the valve degenerated was 8.8 years+/-3.6 and did not differ between the two groups. CONCLUSIONS: AoR is feasible with good hemodynamics, low mortality and thromboembolic rate. Its behavior at 10 years is comparable to that of stentless aortic valve bioprosthesis. It can be performed with either xenopericardium or glutaraldehyde-treated autologous pericardium, but the latter has the advantage of being inexpensive and readily available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aortic valve repair leads to a low incidence of valve-related complications
Aicher, D., Fries, R., Rodionycheva, S., Schmidt, K., Langer, F., & Schäfers, H.-J. (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.06.021 · Cited by 310
Mammalian Pericardium‐Based Bioprosthetic Materials in Xenotransplantation and Tissue Engineering
Grebenik, E. A., Gafarova, E. R., Istranov, L. P., Istranova, E. V., Ma, X., Xu, J., Guo, W., Atala, A., & Timashev, P. S. (2020) · Biotechnology Journal · doi:10.1002/biot.201900334 · Cited by 30
Metadata
- Authors
- Halees, Z. A., Shahid, M. A., Sanei, A. A., Sallehuddin, A., & Duran, C.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-08
- Volume
- 28
- Issue
- 2
- Pages
- 200-205
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2172007885
- Cited by
- 181
- References
- 0
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve?☆. https://app.cochat.ai/papers/10.1016/j.ejcts.2005.04.041
- The paper
- Halees, Z. A., Shahid, M. A., Sanei, A. A., Sallehuddin, A., & Duran, C. (2005). Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve?☆. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/j.ejcts.2005.04.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.