The DOI matches its Crossref record.
Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography☆
Abstract
OBJECTIVE: To evaluate the accuracy of integrated positron emission tomography with 18F-fluoro-2-deoxy-D-glucose (FDG) and computed tomography (PET/CT) in preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer (NSCLC) and to ascertain the role of invasive staging in verifying positron emission tomography (PET)/computed tomography (CT) results. METHODS: Retrospective, single institution study of consecutive patients with suspected or pathologically proven, potentially resectable NSCLC undergoing integrated PET/CT scanning in the same PET centre. Lymph node staging was pathologically confirmed on tissue specimens obtained at mediastinoscopy and/or thoracotomy. Statistical evaluation of PET/CT results was performed on a per-patient and per-nodal-station bases. RESULTS: A total of 1001 nodal stations (723 mediastinal, 148 hilar and 130 intrapulmonary) were evaluated in 159 patients. Nodes were positive for malignancy in 48 (30.2%) out of 159 patients (N1=17; N2=30; N3=1) and 71 (7.1%) out of 1001 nodal stations (N1=24; N2=46; N3=1). At univariate analysis, lymph node involvement was significantly associated (p<0.05) with the following primary tumour characteristics: increasing diameter, maximum standardised uptake value >9, central location and presence of vascular invasion. PET/CT staged the disease correctly in 128 out of 159 patients (80.5%), overstaging occurred in nine patients (5.7%) and understaging in 22 patients (13.8%). The overall sensitivity, specificity, positive and negative predictive values, and accuracy of PET/CT for detecting metastatic lymph nodes were 54.2%, 91.9%, 74.3%, 82.3% and 80.5% on a per-patient basis, and 57.7%, 98.5%, 74.5%, 96.8% and 95.6% on per-nodal-station basis. With regard to N2/N3 disease, PET/CT accuracy was 84.9% and 95.3% on a per-patient basis and on per-nodal-station basis, respectively. Referring to nodal size, PET/CT sensitivity to detect malignant involvement was 32.4% (12/37) in nodes <10mm, and 85.3% (29/34) in nodes > or = 10mm. CONCLUSION: Our data show that integrated PET/CT provides high specificity but low sensitivity and accuracy in intrathoracic nodal staging of NSCLC patients and underscore the continued need for surgical staging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methods for Staging Non-small Cell Lung Cancer
Silvestri, G. A., Gonzalez, A. V., Jantz, M. A., Margolis, M. L., Gould, M. K., Tanoue, L. T., Harris, L. J., & Detterbeck, F. C. (2013) · Chest · doi:10.1378/chest.12-2355 · Cited by 1,483
Non–Small Cell Lung Cancer, Version 2.2013
Ettinger, D. S., Akerley, W., Borghaei, H., Chang, A. C., Cheney, R. T., Chirieac, L. R., D'Amico, T. A., Demmy, T. L., Govindan, R., Grannis, F. W., et al. (2013) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2013.0084 · Cited by 440
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
NCCN Guidelines Insights: Kidney Cancer, Version 2.2020
Motzer, R. J., Jonasch, E., Michaelson, M. D., Nandagopal, L., Gore, J. L., George, S., Alva, A., Haas, N., Harrison, M. R., Plimack, E. R., et al. (2019) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2019.0054 · Cited by 287
Wu, Y., Li, P., Zhang, H., Shi, Y., Wu, H., Zhang, J., Qian, Y., Li, C., & Yang, J. (2013) · International Journal of Cancer · doi:10.1002/ijc.27779 · Cited by 129
Metadata
- Authors
- Billé, A., Pelosi, E., Skanjeti, A., Arena, V., Errico, L., Borasio, P., Mancini, M., & Ardissone, F.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-09
- Volume
- 36
- Issue
- 3
- Pages
- 440-445
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2094440255
- Cited by
- 186
- References
- 0
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography☆. https://app.cochat.ai/papers/10.1016/j.ejcts.2009.04.003
- The paper
- Billé, A., Pelosi, E., Skanjeti, A., Arena, V., Errico, L., Borasio, P., Mancini, M., & Ardissone, F. (2009). Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography☆. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/j.ejcts.2009.04.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.