Infrared camera assessment of skin surface temperature—Effect of emissivity
Open accessAbstract
Infrared thermoimaging is one of the options for object temperature analysis. Infrared thermoimaging is unique due to the non-contact principle of measurement. So it is often used in medicine and for scientific experimental measurements. The presented work aims to determine whether the measurement results could be influenced by topical treatment of the hand surface by various substances. The authors attempted to determine whether the emissivity can be neglected or not in situations of topical application of substances such as ultrasound gel, ointment, disinfection, etc. The results of experiments showed that the value of surface temperature is more or less distorted by the topically applied substance. Our findings demonstrate the effect of emissivity of applied substances on resulting temperature and showed the necessity to integrate the emissivity into calculation of the final surface temperature. Infrared thermoimaging can be an appropriate method for determining the temperature of organisms, if this is understood as the surface temperature, and the surrounding environment and its temperature is taken into account.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Indirect core body temperature evaluation can achieve a high accuracy of ±0.03 °C.
“From these data, the internal core body temperature is evaluated with a high accuracy of ±0.03 °C [129,140,146,147,148,149].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [146]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 44 · Cited by 177
Research works printed but not linked: 10
- Buchmüller K. Über die ultrarote Emission, Reflexion und Durchlässigkeit der lebenden menschlichen Haut im Spektralbereich lz3e15 mm. Pflügers Archiv European Journal of Physiology 1961;272(4):360e71.
- Büttner K. Über die Wärmestrahlung and die reflexionseigenshaften der Menschlichen Haut. Strahlentherapie 1937;58:345e60.
- Czerny M. Über Photographie im Ultraroten 25. Physik 1929;53:1.
- Gärtner W, Göpfert H. Topographische Untersuchungen über die Strahlung- seigenschaften der lebenden menschlichen Haut. Pflügers Archiv European Journal of Physiology 1964;280(3):224e35.
- Gärtner W, Ling K, Göpfert H. Über die Abhängigkeit der Temperaturstrahlung der lebenden menschlichen Haut von der Durchblutung. Pflügers Archiv Eu- ropean Journal of Physiology 1964;280(3):236e42.
- Hackforth HL. Infrared radiation. New York: McGraw Hill; 1960.
- Hollan J. Termografické zji s tování tepelných vlastností budov in situ (zji s tování emisivit a tepelných tok u pomocí termokamery). In: Workshop NDT 2004 non-destructive testing. Brno: Brno University of Technology; 2004.
- Hollan J. Termografické ov e rování tepeln e izola cních vlastností oken se spe- ciálními roletami. In: Workshop NDT 2005 non-destructive testing. Brno: Brno University of Technology; 2005. p. 25e7.
- Patil KD, Williams KL. Spectral study of human radiation. Nonionizing Radi- ation 1954;1:39e44.
- Schwamm E, Reeh J. Die Ultrarotstrahlung des Menschen und seine Mole- kularspektroskopie. Hippokrates 1953;24:737e42.
- Authors
- Bernard, V., Staffa, E., Mornstein, V., & Bourek, A.
- Affiliations
- Masaryk University (CZ)
- Corresponding author
- Bernard, V.
- Venue
- Physica Medica
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 29
- Issue
- 6
- Pages
- 583-591
- ISSN
- 1120-1797 (ISSN-L)
- OpenAlex
- W2049275673
- Cited by
- 177
- References
- 44
- Citations by year
- 2026: 10 · 2025: 14 · 2024: 12 · 2023: 17 · 2022: 20 · 2021: 21 · 2020: 19 · 2019: 18 · 2018: 17 · 2017: 9 · 2016: 7 · 2015: 11 · 2014: 2
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physica Medica (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Civil and Structural Engineering › Thermal Radiation and Cooling Technologies
- Keywords
- infrared thermography, skin surface temperature, emissivity, ultrasound gel, ointments, disinfectants, non-contact temperature measurement, measurement error
- MeSH terms
- Aluminum, Cosmetics, Hand, Humans, Infrared Rays, Skin Temperature, Surface Properties, Thermography, Ultrasonics, Water, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review