The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion tensor tractography in patients with cerebral tumors: A helpful technique for neurosurgical planning and postoperative assessment
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Cited by
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
“These visualization techniques have also been applied after surgical intervention to assess the effects of the surgery on the WM tracts.(14,82,99) In addition to visualization of the WM tracts, DTI has also been used to study the effects of surgery on WM pathways.”
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Duffau, H., Gatignol, P., Mandonnet, E., Capelle, L., & Taillandier, L. (2008) · Journal of Neurosurgery · doi:10.3171/jns/2008/109/9/0461 · Cited by 499
Ciccarelli, O., Catani, M., Johansen-Berg, H., Clark, C., & Thompson, A. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70163-7 · Cited by 412
Diffusion-Tensor MR Imaging and Tractography: Exploring Brain Microstructure and Connectivity
Nucifora, P. G. P., Verma, R., Lee, S.-K., & Melhem, E. R. (2007) · Radiology · doi:10.1148/radiol.2452060445 · Cited by 344
White, N. S., McDonald, C. R., Farid, N., Kuperman, J., Karow, D., Schenker-Ahmed, N. M., Bartsch, H., Rakow-Penner, R., Holland, D., Shabaik, A., et al. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-3534 · Cited by 255
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Girard, G., Caminiti, R., Battaglia-Mayer, A., St-Onge, E., Ambrosen, K. S., Eskildsen, S. F., Krug, K., Dyrby, T. B., Descoteaux, M., Thiran, J.-P., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117201 · Cited by 83
Zemmoura, I., Serres, B., Andersson, F., Barantin, L., Tauber, C., Filipiak, I., Cottier, J.-P., Venturini, G., & Destrieux, C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.016 · Cited by 56
“However, although tractography has already been used for pre-operative planification and per-operative navigation in patients operated on for cerebral tumors (Nimsky et al., 2006; Yu et al., 2005), it has sometimes been shown to lack reliability (Kinoshita et al.”
Background
Metadata
- Authors
- Yu, C. S., Li, K. C., Xuan, Y., Ji, X. M., & Qin, W.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 2005-11
- Volume
- 56
- Issue
- 2
- Pages
- 197-204
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2121140812
- Cited by
- 203
- References
- 1
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.