CoChat

Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview

Stiller, Wolfram · 2018 · European Journal of Radiology
Cited by 160

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Over the past two decades, technical innovations in computed tomography (CT) have constantly extended its spectrum of clinical applications and made new radiodiagnostic applications accessible. At the same time, concerns have arisen with respect to the radiation exposure to the patients caused by CT examinations. In order to address this issue, different strategies for radiation dose reduction in CT have been introduced, spanning technical approaches as well as specific examination techniques applied in clinical practice, such as reduced-dose CT. Developed technical approaches for reducing radiation dose in CT by improvements of CT scanner hardware and acquisition mechanisms, however, have not been sufficient to address the degradation of image quality caused by increasing noise and susceptibility to artifacts inherent to reduced-dose CT acquisitions. Recent advances in computing power have enabled the development of software-based methods for iterative image reconstruction (IR) in CT enabling simultaneous reduction of image noise and improvement of overall image quality. Thereby, IR allows for dose reduction by reconstruction of low-noise image data from intrinsically noisy reduced-dose CT acquisitions, thereby preserving diagnostic image quality equivalent to current clinical standards. This review provides an overview of the underlying basic principles of iterative image reconstruction methods currently available for and applied in CT imaging, independent of vendor-specific details regarding algorithms and implementations. It discusses potential strengths and weaknesses of these CT image reconstruction techniques in view of their application in clinical routine, especially in view of the potential of IR for noise and artifact reduction as well as for radiation dose reduction. Furthermore, the effect of statistical (hybrid) and model-based IR methods on image quality are exemplarily illustrated in comparison to filtered back projection (FBP) traditionally used for image reconstruction in CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejrad.2018.10.025

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Stiller, W.
Venue
European Journal of Radiology
Publisher
Elsevier BV
Published
2018-12
Volume
109
Pages
147-154
ISSN
0720-048X (ISSN-L)
OpenAlex
W2898404836
Cited by
160
References
13
FWCI
7.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.