Variability and Standardization of Quantitative Imaging: Monoparametric to Multiparametric Quantification, Radiomics, and Artificial Intelligence
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Radiological images have been assessed qualitatively in most clinical settings by the expert eyes of radiologists and other clinicians. On the other hand, quantification of radiological images has the potential to detect early disease that may be difficult to detect with human eyes, complement or replace biopsy, and provide clear differentiation of disease stage. Further, objective assessment by quantification is a prerequisite of personalized/precision medicine. This review article aims to summarize and discuss how the variability of quantitative values derived from radiological images are induced by a number of factors and how these variabilities are mitigated and standardization of the quantitative values are achieved. We discuss the variabilities of specific biomarkers derived from magnetic resonance imaging and computed tomography, and focus on diffusion-weighted imaging, relaxometry, lung density evaluation, and computer-aided computed tomography volumetry. We also review the sources of variability and current efforts of standardization of the rapidly evolving techniques, which include radiomics and artificial intelligence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Lakhani, P., & Sundaram, B. (2017) · Radiology · doi:10.1148/radiol.2017162326 · Cited by 1,775
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580 · cited 1×
“If only postprocessed data (eg, fractional anisotropy map and cortical thickness) are available, regression analysis or more sophisticated statistical approaches can be performed for harmonization.(43,44)”
MethodMagnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“In MRF, radiofrequency pulses and repetition times are simultaneously varied in a pseudorandom fashion to create signal evolutions that characterize the various relaxation processes unique for each type of tissue (so-called fingerprint).(131) The acquired signal evolutions are”
BackgroundHarmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261 · cited 1×
“If only postprocessed data (eg, fractional anisotropy map and cortical thickness) are available, regression analysis or more sophisticated statistical approaches can be performed for harmonization.(43,44)”
Method
Cited by
Artificial intelligence and machine learning in cancer imaging
Koh, D.-M., Papanikolaou, N., Bick, U., Illing, R., Kahn, C. E., Kalpathi-Cramer, J., Matos, C., Martí-Bonmatí, L., Miles, A., Mun, S. K., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00199-0 · Cited by 311
Belue, M. J., Harmon, S. A., Lay, N. S., Daryanani, A., Phelps, T. E., Choyke, P. L., & Turkbey, B. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2022.05.022 · Cited by 27
Bhandari, A., Scott, L., Weilbach, M., Marwah, R., & Lasocki, A. (2023) · Neuroradiology · doi:10.1007/s00234-023-03126-9 · Cited by 21
Singh, S., Muniz De Oliveira, F., Wang, C., Kumar, M., Xuan, Y., DeMazumder, D., Sen, C. K., & Roy, S. (2025) · Advances in Wound Care · doi:10.1089/wound.2024.0291 · Cited by 6
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S.
- Venue
- Investigative Radiology
- Published
- 2020-03-24
- Volume
- 55
- Issue
- 9
- Pages
- 601-616
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W3013522077
- Cited by
- 183
- References
- 18
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability and Standardization of Quantitative Imaging: Monoparametric to Multiparametric Quantification, Radiomics, and Artificial Intelligence. https://app.cochat.ai/papers/10.1097/rli.0000000000000666
- The paper
- Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S. (2020). Variability and Standardization of Quantitative Imaging: Monoparametric to Multiparametric Quantification, Radiomics, and Artificial Intelligence. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000666
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.