CoChat

A review of original articles published in the emerging field of radiomics

Open access
Song, Jiangdian, Yin, Yanjie, Wang, Hairui, Chang, Zhihui, Liu, Zhaoyu, Cui, Lei · 2020 · European Journal of Radiology
Cited by 162

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the characteristics of and trends in research in the emerging field of radiomics through bibliometric and hotspot analyses of relevant original articles published between 2013 and 2018. METHODS: We evaluated 553 original articles concerning radiomics, published in a total of 61 peer-reviewed journals between 2013 and 2018. The following information was retrieved for each article: radiological subspecialty, imaging technique(s), machine learning technique(s), sample size, study setting and design, statistical result(s), study purpose, software used for feature calculation, funding declarations, author number, first author's affiliation, study origin, and journal name. Qualitative and quantitative analyses were performed for the manually extracted data for identification and visualization of the trends in radiomics research. RESULTS: The annual growth rate in the number of published papers was 177.82% (p < 0.001). The characteristics and trends of research hotspots in the field of radiomics were clarified and visualized in this study. It was found that the field of radiomics is at a more mature stage for lung, breast, and prostate cancers than for other sites. Radiomics studies primarily focused on radiological characterization (215) and monitoring (182). Logistic regression and LASSO were the two most commonly used techniques for feature selection. Non-clinical researchers without a medical background dominated radiomics studies (70.52%), the vast majority of which only highlighted positive results (97.80%) while downplaying negative findings. CONCLUSIONS: The reporting of quantifiable knowledge about the characteristics and trajectories of radiomics can inform researchers about the gaps in the field of radiomics and guide its future direction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejrad.2020.108991

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 162

Metadata

Authors
Song, J., Yin, Y., Wang, H., Chang, Z., Liu, Z., & Cui, L.
Venue
European Journal of Radiology
Publisher
Elsevier BV
Published
2020-06
Volume
127
Pages
108991
ISSN
0720-048X (ISSN-L)
OpenAlex
W3015320097
Cited by
162
References
8
FWCI
11.77
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review of original articles published in the emerging field of radiomics. https://app.cochat.ai/papers/10.1016/j.ejrad.2020.108991
The paper
Song, J., Yin, Y., Wang, H., Chang, Z., Liu, Z., & Cui, L. (2020). A review of original articles published in the emerging field of radiomics. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2020.108991

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.