Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,468

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular Surgery

Open access
Moll, F.L., Powell, J.T., Fraedrich, G., Verzini, F., Haulon, S., Waltham, M., van Herwaarden, J.A., Holt, P.J.E., van Keulen, J.W., Rantner, B., Schlösser, F.J.V., Setacci, F., Ricco, J.-B.·2011·European Journal of Vascular and Endovascular Surgery

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejvs.2010.09.011

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 1,468

Metadata

Authors
Moll, F. L., Powell, J. T., Fraedrich, G., Verzini, F., Haulon, S., Waltham, M., van Herwaarden, J. A., Holt, P. J. E., van Keulen, J. W., Rantner, B., Schlösser, F. J. V., Setacci, F., & Ricco, J.-B.
Venue
European Journal of Vascular and Endovascular Surgery
Publisher
Elsevier BV
Published
2011-01
Volume
41
Pages
S1-S58
ISSN
1078-5884 (ISSN-L)
OpenAlex
W2154986758
Cited by
1,468
References
4
FWCI
70.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular Surgery. https://app.cochat.ai/papers/10.1016/j.ejvs.2010.09.011
The paper
Moll, F. L., Powell, J. T., Fraedrich, G., Verzini, F., Haulon, S., Waltham, M., van Herwaarden, J. A., Holt, P. J. E., van Keulen, J. W., Rantner, B., Schlösser, F. J. V., Setacci, F., & Ricco, J.-B. (2011). Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular Surgery. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2010.09.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.