The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A novel voltammetric sensor based on gold nanoparticles involved in p-aminothiophenol functionalized multi-walled carbon nanotubes: Application to the simultaneous determination of quercetin and rutin
Open accessAbstract
Abstract Carbon nanotubes are expected to play a significant role in the design and manufacture of many nano-material devices in the future. Carbon nanotubes exhibit many unique properties which generate strong interests in studying their applications. In addition, certain properties of gold nanoparticles (e.g., conductivity, catalytic and photocatalytic activity) suggest that gold-nanoparticle-functionalized carbon nanotubes may prove applicable in future fabrication of nanodevices. In this study, gold nanoparticles (AuNPs) with the mean diameters of 20-25 nm were self-assembled onto the surfaces of p-aminothiophenol functionalized multi-walled carbon nanotubes (p-MWCNs) sheets. The p-MWCNs and AuNPs/p-MWCNs nanocomposites were characterized by reflection–absorption infrared spectroscopy (RAIRS), transmission electron microscope (TEM), x-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS) and x-ray diffraction (XRD) method. The simultaneous determination of quercetin (QR) and rutin (RT) was performed by square wave voltammetry (SWV) on glassy carbon electrode (GCE) modified with AuNPs/p-MWCNs nanocomposite (AuNPs/p-MWCNs-GCE). QR presented two oxidation steps at E a1 of 270 mV and E a2 of 450 mV and RT presented only one oxidation step at E a of 360 mV at AuNPs/p-MWCNs-GCE. The linearity ranges and the detection limits of QR and RT were 1.0 × 10 −9 - 5.0 × 10 −8 M and 3.3 × 10 −10 . The application of the prepared nanocomposite to the analysis of real sample was also investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Room-temperature transistor based on a single carbon nanotube
Tans, S. J., Verschueren, A. R. M., & Dekker, C. (1998) · Nature · doi:10.1038/29954 · Cited by 5,425
Ajayan, P. M. (1999) · Chemical Reviews · doi:10.1021/cr970102g · Cited by 3,151
Antioxidant activity and phenolic compounds in 32 selected herbs
WOJDYLO, A., OSZMIANSKI, J., & CZEMERYS, R. (2007) · Food Chemistry · doi:10.1016/j.foodchem.2007.04.038 · Cited by 2,023
Carbon nanotubule membranes for electrochemical energy storage and production
Che, G., Lakshmi, B. B., Fisher, E. R., & Martin, C. R. (1998) · Nature · doi:10.1038/30694 · Cited by 1,767
A review of the interaction among dietary antioxidants and reactive oxygen species
Seifried, H. E., Anderson, D. E., Fisher, E. I., & Milner, J. A. (2007) · The Journal of Nutritional Biochemistry · doi:10.1016/j.jnutbio.2006.10.007 · Cited by 894
Pharmacokinetics of quercetin from quercetin aglycone and rutin in healthy volunteers
Erlund, I., Kosonen, T., Alfthan, G., Mäenpää, J., Perttunen, K., Kenraali, J., Parantainen, J., & Aro, A. (2000) · European Journal of Clinical Pharmacology · doi:10.1007/s002280000197 · Cited by 523
Improved Charge Transfer at Carbon Nanotube Electrodes
Britto, P. J., Santhanam, K. S. V., Rubio, A., Alonso, J. A., & Ajayan, P. M. (1999) · Advanced Materials · doi:10.1002/(sici)1521-4095(199902)11:2<154::aid-adma154>3.0.co;2-b · Cited by 515
Hong, W., Bai, H., Xu, Y., Yao, Z., Gu, Z., & Shi, G. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp9101724 · Cited by 400
Zu, Y., Li, C., Fu, Y., & Zhao, C. (2006) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2005.04.052 · Cited by 339
Cited by
Carbon nanotube based biosensors
Yang, N., Chen, X., Ren, T., Zhang, P., & Yang, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.10.040 · Cited by 542
Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/ie504438z · Cited by 412
Self-citationA review on carbon nanotubes in biosensor devices and their applications in medicine
Sireesha, M., Jagadeesh Babu, V., Kranthi Kiran, A. S., & Ramakrishna, S. (2018) · Nanocomposites · doi:10.1080/20550324.2018.1478765 · Cited by 271
Enhanced electrochemical detection of quercetin by Natural Deep Eutectic Solvents
Gomez, F. J. V., Espino, M., de los Angeles Fernandez, M., Raba, J., & Silva, M. F. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.022 · Cited by 91
Metadata
- Authors
- Yola, M. L., & Atar, N.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 119
- Pages
- 24-31
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W2049764852
- Cited by
- 263
- References
- 31
- FWCI
- 15.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.