The DOI matches its Crossref record.
A Novel DNA Biosensor Based on a Pencil Graphite Electrode Modified with Polypyrrole/Functionalized Multiwalled Carbon Nanotubes for Determination of 6-Mercaptopurine Anticancer Drug
Open accessAbstract
A novel and sensitive biosensor employing immobilized DNA on a pencil graphite electrode modified with polypyrrole/functionalized multiwalled carbon nanotubes for the determination of 6-mercaptopurine (6-MP) is presented. In the first step, we modified the pencil graphite surface with polypyrrole and functionalized multiwalled carbon nanotubes (MWCNT/COOH). The developed electrode was characterized by scanning electron microscopy, atomic force microscopy, reflection–absorption infrared spectroscopy, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy. In the other step, we used decreases in the oxidation responses of guanine and adenine as a sign of the interaction of 6-MP with salmon sperm double-stranded DNA using differential pulse voltammetry. The signal of guanine oxidation was linear with respect to the 6-MP concentration in the range of 0.2–100 μmol L –1 with a detection limit of 0.08 μmol L –1 . The modified electrode was utilized for the determination of 6-MP in real samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Karimi-Maleh, H., Shojaei, A. F., Tabatabaeian, K., Karimi, F., Shakeri, S., & Moradi, R. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.07.086 · Cited by 293
Self-citationKarimi-Maleh, H., Karimi, F., Malekmohammadi, S., Zakariae, N., Esmaeili, R., Rostamnia, S., Yola, M. L., Atar, N., Movaghgharnezhad, S., Rajendran, S., et al. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2020.113185 · Cited by 284
Self-citationMohanraj, J., Durgalakshmi, D., Rakkesh, R. A., Balakumar, S., Rajendran, S., & Karimi-Maleh, H. (2020) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2020.01.089 · Cited by 282
Self-citationMicroneedle-based biosensor for minimally-invasive lactate detection
Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.010 · Cited by 267
Zhou, T., Yan, L., Xie, C., Li, P., Jiang, L., Fang, J., Zhao, C., Ren, F., Wang, K., Wang, Y., et al. (2019) · Small · doi:10.1002/smll.201805440 · Cited by 143
Metadata
- Authors
- Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A.
- Venue
- Industrial & Engineering Chemistry Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-04-03
- Volume
- 54
- Issue
- 14
- Pages
- 3634-3639
- ISSN
- 0888-5885 (ISSN-L)
- 1520-5045
- OpenAlex
- W2332947047
- Cited by
- 412
- References
- 0
- FWCI
- 28.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel DNA Biosensor Based on a Pencil Graphite Electrode Modified with Polypyrrole/Functionalized Multiwalled Carbon Nanotubes for Determination of 6-Mercaptopurine Anticancer Drug. https://app.cochat.ai/papers/10.1021/ie504438z
- The paper
- Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015). A Novel DNA Biosensor Based on a Pencil Graphite Electrode Modified with Polypyrrole/Functionalized Multiwalled Carbon Nanotubes for Determination of 6-Mercaptopurine Anticancer Drug. Industrial & Engineering Chemistry Research. https://doi.org/10.1021/ie504438z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.