The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel and sensitive electrochemical DNA biosensor based on Fe@Au nanoparticles decorated graphene oxide
Open accessAbstract
A novel and sensitive electrochemical biosensor for selective determination of DNA was developed based on Fe@Au nanoparticles (Fe@AuNPs) involving 2-aminoethanethiol (AET) functionalized graphene oxide (GO) (Fe@AuNPs-AETGO). Firstly, 5′-TA CCG GGT GCT CGA GCT-(CH 2 ) 3 -SH-3′ single-stranded probe (ss-DNA) was immobilized on Fe@AuNPs-AETGO nanocomposite to form ssDNA-Fe@AuNPs-AETGO. Square wave voltammetry (SWV) was applied to monitor the DNA hybridization by basic blue 41 (BB41) as an electrochemical indicator. The DNA immobilization and hybridization on the film were studied by cyclic voltammetry (CV), SWV and electrochemical impedance spectroscopy (EIS). Under optimum conditions, the peak currents of BB41 were linear with the logarithm of the concentrations of complementary DNA (5′-AT GGC CCA CGA GCT CGA-(CH 2 ) 3 -SH-3) from 1.0 × 10 −14 to 1.0 × 10 −8 M with a detection limit of 2.0 × 10 −15 M. The biosensor also showed high selectivity to one-base, two-base and three-base mismatched DNA. Compared with the other electrochemical DNA biosensors, the proposed biosensor showed its own performance of simplicity, good stability and high sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dye Adsorption on Layered Graphite Oxide
Bradder, P., Ling, S. K., Wang, S., & Liu, S. (2011) · Journal of Chemical & Engineering Data · doi:10.1021/je101049g · Cited by 381
Cited by
Sensors and biosensors based on magnetic nanoparticles
Rocha-Santos, T. A. P. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.016 · Cited by 547
Recent advances in graphene-based biosensor technology with applications in life sciences
Peña-Bahamonde, J., Nguyen, H. N., Fanourakis, S. K., & Rodrigues, D. F. (2018) · Journal of Nanobiotechnology · doi:10.1186/s12951-018-0400-z · Cited by 545
Karimi-Maleh, H., Tahernejad-Javazmi, F., Atar, N., Yola, M. L., Gupta, V. K., & Ensafi, A. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/ie504438z · Cited by 412
Self-citationAu and Au-Based nanomaterials: Synthesis and recent progress in electrochemical sensor applications
Xiao, T., Huang, J., Wang, D., Meng, T., & Yang, X. (2020) · Talanta · doi:10.1016/j.talanta.2019.120210 · Cited by 349
Singh, D. P., Herrera, C. E., Singh, B., Singh, S., Singh, R. K., & Kumar, R. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.01.004 · Cited by 313
Metadata
- Authors
- Yola, M. L., Eren, T., & Atar, N.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 125
- Pages
- 38-47
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W2018274621
- Cited by
- 223
- References
- 1
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel and sensitive electrochemical DNA biosensor based on Fe@Au nanoparticles decorated graphene oxide. https://app.cochat.ai/papers/10.1016/j.electacta.2014.01.074
- The paper
- Yola, M. L., Eren, T., & Atar, N. (2014). A novel and sensitive electrochemical DNA biosensor based on Fe@Au nanoparticles decorated graphene oxide. Electrochimica Acta. https://doi.org/10.1016/j.electacta.2014.01.074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.