The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Pressurized operation of anion exchange membrane water electrolysis
Abstract
Abstract Water electrolyzers that use an anion exchange membrane (AEM) are expected to be new devices for hydrogen (H2) production that achieve high performance at low capital cost. Such an AEM electrolyzer could produce pressurized H2 as easily as does as a proton exchange membrane (PEM) electrolyzer. In this study, H2 pressure in an AEM electrolyzer was increased to 8.5 bars in the cell. Here, the effect of such high H2 pressure on electrolysis performance was verified by simultaneously measuring the dependency of several parameters on current density during pressurized operation; parameters such as cell voltage, cell resistance, H2 content in the anode gas, H2 production rate, and water content in the produced H2. Results also revealed that pressurized operation of AEM electrolysis offered the advantage of low humidity H2 production, with minimal degradation in the electrolysis performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First implementation of alkaline polymer electrolyte water electrolysis working only with pure water
Xiao, L., Zhang, S., Pan, J., Yang, C., He, M., Zhuang, L., & Lu, J. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22146b · Cited by 313
Cited by
Chatenet, M., Pollet, B. G., Dekel, D. R., Dionigi, F., Deseure, J., Millet, P., Braatz, R. D., Bazant, M. Z., Eikerling, M., Staffell, I., et al. (2022) · Chemical Society Reviews · doi:10.1039/d0cs01079k · Cited by 2,025
Anion-Exchange Membrane Water Electrolyzers
Du, N., Roy, C., Peach, R., Turnbull, M., Thiele, S., & Bock, C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00854 · Cited by 1,075
Miller, H. A., Bouzek, K., Hnat, J., Loos, S., Bernäcker, C. I., Weißgärber, T., Röntzsch, L., & Meier-Haack, J. (2020) · Sustainable Energy & Fuels · doi:10.1039/c9se01240k · Cited by 785
Advances in alkaline water electrolyzers: A review
David, M., Ocampo-Martínez, C., & Sánchez-Peña, R. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2019.03.001 · Cited by 750
Durability of anion exchange membrane water electrolyzers
Li, D., Motz, A. R., Bae, C., Fujimoto, C., Yang, G., Zhang, F.-Y., Ayers, K. E., & Kim, Y. S. (2021) · Energy & Environmental Science · doi:10.1039/d0ee04086j · Cited by 601
The promise of hydrogen production from alkaline anion exchange membrane electrolyzers
Li, C., & Baek, J.-B. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106162 · Cited by 425
Overview: State-of-the Art Commercial Membranes for Anion Exchange Membrane Water Electrolysis
Henkensmeier, D., Najibah, M., Harms, C., Žitka, J., Hnát, J., & Bouzek, K. (2021) · Journal of Electrochemical Energy Conversion and Storage · doi:10.1115/1.4047963 · Cited by 382
Gao, X., Chen, Y., Wang, Y., Zhao, L., Zhao, X., Du, J., Wu, H., & Chen, A. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01424-2 · Cited by 352
Xu, Q., Zhang, L., Zhang, J., Wang, J., Hu, Y., Jiang, H., & Li, C. (2022) · EnergyChem · doi:10.1016/j.enchem.2022.100087 · Cited by 341
Salehmin, M. N. I., Husaini, T., Goh, J., & Sulong, A. B. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115985 · Cited by 329
A comprehensive review of alkaline water electrolysis mathematical modeling
Hu, S., Guo, B., Ding, S., Yang, F., Dang, J., Liu, B., Gu, J., Ma, J., & Ouyang, M. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.120099 · Cited by 253
Alia, S. M., Ha, M.-A., Ngo, C., Anderson, G. C., Ghoshal, S., & Pylypenko, S. (2020) · ACS Catalysis · doi:10.1021/acscatal.0c01568 · Cited by 40
Caprì, A., Martínez-Lázaro, A., Béjar, J., Gatto, I., Álvarez-Contreras, L., Gurrola, M. P., Ledesma-García, J., Baglio, V., & Arriaga, L. G. (2023) · Electrochimica Acta · doi:10.1016/j.electacta.2023.142851 · Cited by 12
Metadata
- Authors
- Ito, H., Kawaguchi, N., Someya, S., & Munakata, T.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 297
- Pages
- 188-196
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W2900506574
- Cited by
- 79
- References
- 1
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.