Impact of façade window design on energy, daylighting and thermal comfort in nearly zero-energy houses
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Daylight Performance Metrics for Sustainable Building Design
Reinhart, C. F., Mardaljevic, J., & Rogers, Z. (2006) · LEUKOS The Journal of the Illuminating Engineering Society of North America · doi:10.1582/leukos.2006.03.01.001 · Cited by 812 · cited 1×
“Furthermore, the use of daylight factor requirements can sometimes result in conflicts between visual and thermal comfort requirements [39].”
BackgroundOchoa, C. E., Aries, M. M., van Loenen, E. J., & Hensen, J. J. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.02.042 · Cited by 407
EnergyPlus Energy Simulation Software
Gerber, M. A. (2014) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 374
Daylight metrics and energy savings
Mardaljevic, J., Heschong, L., & Lee, E. (2009) · Lighting Research & Technology · doi:10.1177/1477153509339703 · Cited by 369 · cited 1×
“Over the last decade, research in the field of daylighting has discussed the shortcomings of the daylight factor method [37, 38].”
BackgroundAlWaer, H., & Clements-Croome, D. J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.08.019 · Cited by 359
Lee, J. W., Jung, H. J., Park, J. Y., Lee, J. B., & Yoon, Y. (2013) · Renewable Energy · doi:10.1016/j.renene.2012.07.029 · Cited by 308 · cited 1×
“[4] examined the effect of window-to-wall ratios, orientation, Uvalue, g-value and visual transmittance to find optimal window designs for office buildings in 5 typical climate zones in Asia.”
BackgroundInfluence of window size on the energy balance of low energy houses
Persson, M.-L., Roos, A., & Wall, M. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2005.05.006 · Cited by 255 · cited 1×
“[14] on the performance of passive houses in Sweden has shown that window size is not that important any more for the reduction of heating demand.”
BackgroundGasparella, A., Pernigotto, G., Cappelletti, F., Romagnoni, P., & Baggio, P. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.12.032 · Cited by 207 · cited 1×
“Studies on reducing the heating and cooling demand in residential buildings have considered the influence of window orientation, size and glazing type and suggested that south-facing window size is important for reducing heating demand [10-13].”
BackgroundSusorova, I., Tabibzadeh, M., Rahman, A., Clack, H. L., & Elnimeiri, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.035 · Cited by 187 · cited 1×
“[2] and Ghisi and Tinker [3] focused on the effect of room geometry, window size and orientation on energy use for heating, cooling and lighting for office buildings in various climate zones.”
BackgroundA framework for predicting the non-visual effects of daylight – Part I: photobiology- based model
Andersen, M., Mardaljevic, J., & Lockley, S. (2012) · Lighting Research & Technology · doi:10.1177/1477153511435961 · Cited by 177 · cited 1×
“4 of 18 Recently, there has been renewed attention on the thermal indoor environment and potential nonvisual effects of daylighting in residential buildings [15] as part of a movement towards sustainable buildings with a focus on user well-being [16].”
BackgroundOptimum, technical and energy efficiency design of residential building in Mediterranean region
Jaber, S., & Ajib, S. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.03.024 · Cited by 139 · cited 1×
“Studies on reducing the heating and cooling demand in residential buildings have considered the influence of window orientation, size and glazing type and suggested that south-facing window size is important for reducing heating demand [10-13].”
BackgroundPerforming complex parametric simulations with jEPlus
Zhang, Y., & Korolija, I. (2010) · DMU Open Research Archive (De Montfort University) · Cited by 115
Examples of Climate-Based Daylight Modelling
Mardaljevic, J. (2006) · Cited by 98
Toftum, J., Andersen, R. K., & Jensen, K. L. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.007 · Cited by 91 · cited 1×
“restricting n of therm ed as a ne h [36].”
Background
Cited by
Thermochromic smart window technologies for building application: A review
Aburas, M., Soebarto, V., Williamson, T., Liang, R., Ebendorff-Heidepriem, H., & Wu, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113522 · Cited by 425
Pilechiha, P., Mahdavinejad, M., Pour Rahimian, F., Carnemolla, P., & Seyedzadeh, S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114356 · Cited by 259
Metadata
- Authors
- Vanhoutteghem, L., Skarning, G. C. J., Hviid, C. A., & Svendsen, S.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2015-09
- Volume
- 102
- Pages
- 149-156
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W1840208908
- Cited by
- 162
- References
- 14
- FWCI
- 15.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.