Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Using footwarmers in offices for thermal comfort and energy savings

Open access
Zhang, Hui, Arens, Edward, Taub, Mallory, Dickerhoff, Darryl, Bauman, Fred, Fountain, Marc, Pasut, Wilmer, Fannon, David, Zhai, Yongchao, Pigman, Margaret · 2015 · Energy and Buildings

Abstract

An office equipped with personal footwarmers was maintained at cooler-than-normal indoor temperatures in the winter, producing great energy savings. The occupants’ thermal comfort was not affected. The footwarmers provide individual heating control over a segment of the body that most strongly influences comfort perception when one is cool overall. If cooler ambient indoor temperatures could be made comfortable, savings in central heating energy would be possible. During a six-month winter period in Berkeley California, knowledge workers with low-energy footwarmers experienced a lowering of room heating set point from 21.1 °C (70 °F) to 18.9 °C (66 °F). Surveys showed equal thermal comfort in the original ‘higher heating setpoint no-footwarmer’ condition and the ‘lower heating set point plus occupant-controllable footwarmer’ condition. Heating energy was closely monitored throughout. It dropped 38–75% depending on the setpoint reduction and outdoor conditions. The added plug load energy from the low-energy footwarmers was much less than the central heating energy saved by lowering the heating set point (3–21 W vs 500–700 W average power per occupant during occupied hours). A few subjects had ergonomic issues with the particular footwarmers used, so usage was not universal. Additional foot- and leg-warmer design options would help.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2015.06.086

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 168

Metadata

Authors
Zhang, H., Arens, E., Taub, M., Dickerhoff, D., Bauman, F., Fountain, M., Pasut, W., Fannon, D., Zhai, Y., & Pigman, M.
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2015-10
Volume
104
Pages
233-243
ISSN
0378-7788 (ISSN-L)
OpenAlex
W795862951
Cited by
168
References
2
FWCI
9.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using footwarmers in offices for thermal comfort and energy savings. https://app.cochat.ai/papers/10.1016/j.enbuild.2015.06.086
The paper
Zhang, H., Arens, E., Taub, M., Dickerhoff, D., Bauman, F., Fountain, M., Pasut, W., Fannon, D., Zhai, Y., & Pigman, M. (2015). Using footwarmers in offices for thermal comfort and energy savings. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2015.06.086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.