CoChat

A computational multi-objective optimization method to improve energy efficiency and thermal comfort in dwellings

Open access
Bre, Facundo, Fachinotti, Víctor D. · 2017 · Energy and Buildings
Cited by 180

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

In the last years, multi-objective optimization techniques became into one of the main challenges of the building energy efficiency area. The objective of this paper is to develop and validate a computational code for multi-objective building performance optimization by linking an evolutionary algorithm and a building simulation software in a powerful cluster. A sophisticated version of the multi-objective Non-dominated Sorting Genetic Algorithm-II (NSGA-II) was implemented in Python code to determine the optimal building design, which allows working with categorical and discrete variables, and the objectives were evaluated using the building energy simulation software EnergyPlus. NSGA-II was implemented to run in a high-performance cluster for the parallel computing of the fitness of each population (set of possible designs). In this work, the strengths of the proposed method were demonstrated by its application to the optimal design of a typical single-family house, located in the Argentine Littoral region. This house has some rooms conditioned only by natural ventilation, and other rooms with natural ventilation supplemented by mechanical air-conditioning (hybrid ventilation). The most influential design variables like roof types, external and internal wall types, solar orientation, solar absorptance, size, type, and windows shading of this house among others were studied in two complex cases of 10 8 and 10 16 possibilities to obtain the best trade-off (Pareto front) between heating and cooling performance. Finally, a decision-making method was applied to select one configuration of the Pareto front. Optimal simulation results for the study cases indicated that is possible to improve up to 95% the thermal comfort in naturally ventilated rooms and up to 82% energy performance in air-conditioned rooms of the building with respect to the original configuration by using a design that takes simultaneous advantage of passive strategies like thermal inertia and natural ventilation. The methodology was proved to give a robust and powerful tool to design efficient dwellings reducing the optimization time from almost 12 days to 4.4 h.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2017.08.002

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Bre, F., & Fachinotti, V. D.
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2017-11
Volume
154
Pages
283-294
ISSN
0378-7788 (ISSN-L)
OpenAlex
W2742301504
Cited by
180
References
6
FWCI
10.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.